Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
hima safety related digital output module f4204 original new-0

HIMA

Home >  Products >  HIMA

HIMA Safety-Related Digital Output Module F4204 Original new

Product Name: Safety-Related Digital Output Module

Brand Name: HIMA

Model Number:F4204

Country of Origin:GERMANY

Warranty: 12 Months

Whatsapp:+86 18159889985

Email:[email protected]

  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Functions
  • Features
  • Theory of Operation
  • FAQ
  • Recommended Products

Overview

Brand Name:

HIMA

Model Number:

F4204

Country of Origin:

GERMANY

Packaging Details:

Original new Factory Sealed

Delivery Time:

Delivery time in stock

Payment Terms:

T/T

Supply Ability:

in stock

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter

Specification

Model

F4204

Manufacturer

HIMA Paul Hildebrandt GmbH + Co. KG

Product Type

Safety-Related Digital Output Module

System Compatibility

HIMatrix, Planar F, H41q/H51q, HIMax

Output Channels (Variant 1)

8 channels

Output Channels (Variant 2)

16 channels

Output Channels (Variant 3)

6 channels (NO/NC configurable)

Channel Current Rating

250 mA / 1 A / 2 A per channel (variant-dependent)

Nominal Voltage

24 V DC

Response Time

<1 ms

Safety Integrity Level

SIL 2 (IEC 61508) / Cat. 3 (EN 954-1) / PL d (EN ISO 13849-1)

Protection Class

IP20

Operating Temperature

–25°C to +70°C

Storage Temperature

–40°C to +85°C

Weight

0.18–0.45 kg (variant-dependent)

Dimensions (Variant 1)

120 × 25 × 90 mm

Dimensions (Variant 2)

80 × 48 × 35 mm

Dimensions (Variant 3)

3.2 × 21 × 13.3 cm

Mounting

DIN rail or 19″ rack (Planar F sub-rack)

Hazardous Area

Suitable for Ex-zone 2

Certifications

CE, RoHS, TÜV

Description

The F4204 is a safety‑related digital output module from HIMA, engineered to provide reliable discrete output control for safety‑critical industrial automation systems. The F4204 is available in multiple variants—8‑channel, 16‑channel, and 6‑channel (NO/NC configurable)—and is designed for integration into HIMA platforms including HIMatrix, Planar F, H41q/H51q, and HIMax. Operating on a nominal 24 V DC supply with sub‑millisecond response time, the F4204 drives actuators, solenoids, and interlock logic in emergency shutdown (ESD), burner management, and machine safety applications. With TÜV certification, SIL 2 compliance, and Ex‑zone 2 suitability, the F4204 delivers reliable, fail‑safe performance for demanding industrial environments.

Functions

  • Digital Output Actuation – Converts logic commands from the safety controller into discrete output signals to drive field actuators, solenoids, relays, and indicators

  • Fail‑Safe Operation – Configurable outputs (NO or NC) ensure a safe state upon power loss or fault detection

  • Redundant Output Control – Supports safety loops with independent channel isolation to prevent fault propagation

  • Safety Logic Execution – Bridges the central control subsystem with critical field instrumentation for ESD, burner control, and machine protection

  • Watchdog Timer – Prevents outputs from being stuck in a hazardous state

Features

  • Multiple Channel Configurations – Available in 6‑channel (NO/NC configurable), 8‑channel, and 16‑channel variants

  • High-Speed Response – Sub‑millisecond (<1 ms) response time ensures timely actuation

  • Safety Isolation – Each output channel features safety isolation to prevent fault propagation

  • Wide Temperature Range – Operates from –25°C to +70°C, suitable for harsh industrial environments

  • Hazardous Area Ready – Suitable for installation in Ex‑zone 2 classified areas

  • Standard European PCB Form Factor – Ensures stable mechanical fit within Planar F system sub‑racks

  • Comprehensive Safety Certifications – SIL 2 (IEC 61508), Cat. 3 (EN 954-1), PL d (EN ISO 13849-1), TÜV certified

  • Compact DIN‑Rail Design – Space‑efficient footprint for control cabinet installation

Theory of Operation

The F4204 functions as a safety‑related digital output interface within the HIMA safety automation architecture. It receives logic commands from the safety controller (e.g., HIMatrix, H41q/H51q, or HIMax) via the system backplane or fieldbus communication. The module processes these commands and drives the corresponding output channels to actuate field devices such as solenoids, valves, actuators, and indicator lamps.

Each output channel is electrically isolated to prevent fault propagation between channels. Depending on the variant, channels can be configured as normally open (NO) or normally closed (NC) to suit specific safety loop requirements. The module incorporates a watchdog timer that continuously monitors the communication link with the controller; if communication is lost or a fault is detected, the outputs are forced to a pre‑defined safe state.

The module is continuously self‑tested during operation to ensure output integrity. The fail‑safe design ensures that upon loss of power or internal fault detection, all outputs are de‑energised, placing the connected actuators in their safe state. This makes the F4204 suitable for emergency shutdown (ESD), burner management, and machine protection applications where reliable, predictable fail‑safe behaviour is critical.

FAQ

Q1: What is the primary function of the F4204?

A1: The F4204 is a safety‑related digital output module that provides reliable discrete output control for safety‑critical applications, driving actuators, solenoids, and interlock logic in ESD, burner control, and machine safety systems.

Q2: What are the available channel configurations for the F4204?

A2: The F4204 is available in multiple variants: 6‑channel (NO/NC configurable), 8‑channel, and 16‑channel configurations. Confirm the variant for your specific system.

Q3: What safety certifications does the F4204 hold?

A3: The F4204 is certified for SIL 2 (IEC 61508), Cat. 3 (EN 954-1), and PL d (EN ISO 13849-1) safety applications. It also carries TÜV certification.

Q4: What is the operating temperature range of the F4204?

A4: The F4204 operates reliably from –25°C to +70°C, with a storage temperature range of –40°C to +85°C.

Q5: Is the F4204 suitable for hazardous area installations?

A5: Yes. The F4204 is suitable for installation in Ex‑zone 2 hazardous areas.

Inquiry Now :[email protected]