Product Name:Expander Interface Module
Brand Name: ICS TRIPLEX
Model Number:T8850
Country of Origin:USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
ICS TRIPLEX |
Model Number: |
T8850 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Model |
T8850 |
|
Manufacturer |
ICS Triplex / Rockwell Automation |
|
Product Type |
40-Channel Analogue or Digital Output Field Termination Assembly (FTA) |
|
Architecture |
Trusted TMR (Triple Modular Redundant) system component |
|
Compatible Modules |
T8451 (24 Vdc DO), T8461 (24/48 Vdc DO), T8480 (Analogue Output) |
|
Number of Channels |
40 (arranged in 5 isolated groups × 8 channels) |
|
Field Voltage |
24 Vdc nominal (18–32 Vdc range) |
|
Max Field Voltage (Without Damage) |
60 Vdc |
|
Terminal Wire Size |
12 to 28 AWG |
|
Connections |
Screw-clamp terminals; 2-wire field device connections |
|
Mounting |
Standard DIN rail (TS32 or TS35, horizontal or vertical) |
|
Connectors |
JDH1 (SmartSlot), JDH2 (96-pin signal), P1 (10-way power) |
|
LED Indicators |
On-board per-group field power status |
|
SmartSlot Support |
Yes – ‘one to many’ hot replacement |
|
Safety Certification |
SIL-3 (IEC 61508), TÜV |
|
Certifications |
CE, UL |
|
Dimensions (approx.) |
30.2x12.5x6.2cm |
|
Weight |
0.62kg |
|
Operating Temperature |
–20°C to +70°C |
The T8850 is a 40‑channel Field Termination Assembly (FTA) from ICS Triplex‘s Trusted series, engineered as the primary interface between Trusted TMR output modules and field actuators in safety instrumented systems. The T8850 provides 40 output channels arranged in five isolated groups of eight, each with independent power and fused protection. The T8850 is compatible with T8451 (24 Vdc digital output), T8461 (24/48 Vdc digital output), and T8480 (analogue output) modules, and supports SmartSlot hot‑swap capability for online replacement without rewiring. With screw‑clamp terminals, DIN rail mounting, and on‑board LED power status indication, the T8850 delivers reliable, high‑density output termination for emergency shutdown and process interlock applications.
Mounting – Install the T8850 on a standard TS32 or TS35 DIN rail in horizontal or vertical orientation as required.
Module Connection – Connect the Trusted output module (T8451, T8461, or T8480) to the FTA via a dedicated SmartSlot or Companion Slot cable (e.g., TC‑200 series). The cable terminates at JDH2 (96‑pin signal) and JDH1 (SmartSlot) connectors on the FTA.
Field Wiring – Connect field devices (valves, solenoids, indicators) to the TB2 dual‑height terminal blocks using 2‑wire connections. Use screw‑clamp terminals with 12–28 AWG wire.
Power Supply – Connect dual 24 Vdc field power feeds to the P1 10‑way terminal block. Each of the five isolated groups (8 channels) receives independent power with individual fused protection.
0V Reference – The 0V connection at the FTA end allows the module to measure its output voltage. Connect this to the field 0V supply.
LED Indication – On‑board LEDs provide visual status of field power integrity for each power group.
Hot‑Swap – SmartSlot support enables replacement of output modules without disconnecting field wiring or system shutdown.
40 High‑Density Output Channels – Supports up to 40 field output loops in a single FTA, maximising cabinet space efficiency
Five Isolated Power Groups – Each group of 8 channels is independently isolated, preventing cross‑group interference and containing faults to the affected group
Per‑Group Fused Protection – Each group has independent, replaceable fuses; a single‑channel fault does not cascade to other groups
Dual Purpose Analogue/Digital Support – Compatible with both digital output modules (T8451, T8461) and analogue output modules (T8480)
SmartSlot Hot‑Swap Capability – Enables ‘one to many’ online replacement of output modules without rewiring field cables
Screw‑Clamp Terminals – Accepts 12–28 AWG wire for secure, reliable field connections
Standard DIN Rail Mounting – Compatible with TS32 or TS35 rails, horizontal or vertical installation
On‑Board LED Indication – Provides visual field power status for each channel group, simplifying troubleshooting
SIL‑3 Certified – Meets IEC 61508 SIL‑3 safety integrity requirements for critical safety applications
Robust Electrical Isolation – Group‑to‑group isolation suppresses ground loop interference from VFDs and excitation cabinets
The T8850 functions as the passive termination and signal distribution hub between the Trusted TMR output module (T8451, T8461, or T8480) and the field actuators. It does not perform active logic processing—that function resides in the Trusted output module itself. Instead, the T8850 provides the physical interface for field wiring, power distribution, and signal routing.
The 40 output channels are grouped into five isolated banks of eight channels each. Each group receives independent 24 Vdc field power from the P1 terminal block, with individual fused protection per channel. This group isolation ensures that a short circuit or overcurrent fault on one channel is contained within that group and does not affect other groups or the system logic.
Signals from the Trusted output module are transmitted to the T8850 via a dedicated 96‑pin SmartSlot or Companion Slot cable (e.g., TC‑200 series). The cable connects to JDH2 (signal) and JDH1 (SmartSlot) on the FTA. The field power return (0V) connection at the FTA provides a reference for the output module to measure its output voltage.
On‑board LEDs indicate field power integrity for each group, enabling rapid visual fault diagnosis. The SmartSlot interface supports hot‑swap replacement of output modules without disconnecting field wiring, minimising downtime during maintenance. The T8850 is designed to meet SIL‑3 safety integrity requirements, making it suitable for emergency shutdown (ESD), fire & gas (F&G), and burner management systems (BMS).
Q1: What is the primary function of the T8850?
A1: The T8850 is a 40‑channel Field Termination Assembly (FTA) that provides the physical wiring interface between Trusted TMR output modules (T8451, T8461, T8480) and field actuators such as valves, solenoids, and indicators.
Q2: Which output modules are compatible with the T8850?
A2: The T8850 is compatible with the T8451 (24 Vdc digital output), T8461 (24/48 Vdc digital output), and T8480 (analogue output) Trusted TMR modules.
Q3: How many channels does the T8850 provide and how are they arranged?
A3: The T8850 provides 40 output channels, arranged in five isolated groups of eight channels each.
Q4: Does the T8850 support hot‑swappable module replacement?
A4: Yes. The T8850 features a SmartSlot connection that enables ‘one to many’ hot replacement of output modules without disconnecting field wiring or shutting down the system.
Q5: What safety certification does the T8850 hold?
A5: The T8850 is certified to SIL‑3 per IEC 61508 and carries TÜV, CE, and UL approvals, making it suitable for safety‑critical applications such as emergency shutdown and process interlock systems.
Inquiry Now : [email protected]