The HONEYWELL 10104/2/1 is a 16-channel digital input module engineered for the Honeywell Fail Safe Control (FSC) architecture. Operating on a 24 Vdc nominal signal standard, the HONEYWELL 10104/2/1 accurately captures and converts discrete field states into internal system-readable logic. Built to standard 3U Eurocard form factors, the HONEYWELL 10104/2/1 module integrates smoothly into industrial control system racks requiring dependable multi-channel digital monitoring.
Main Function
The main function of the HONEYWELL 10104/2/1 module is to provide sixteen independent 24 Vdc digital input channels for interfacing discrete field signals (such as switches and status contacts) with the Honeywell Fail Safe Control (FSC) system. Note from official hardware specifications that the inputs on the HONEYWELL 10104/2/1 are un-tested (non-safe-tested variant), meaning they are utilized for standard digital status acquisition rather than critical fail-safe safety instrumented loops.
Commercial Terms
Minimum Order Quantity |
1 Piece |
Price |
Contact for Winnie |
Packaging Details |
Original new Factory Sealed |
Delivery Time |
3–7 Days |
Payment Terms |
T/T |
Shipping Method |
DHL / FedEx / UPS / TNT |
Supply Ability |
In stock |
|
Sales: |
Email: |
Whatsapp: |
|
JIM |
|
Manufacturer |
HONEYWELL |
|
Product Type |
Digital Input Module |
|
Part Number |
10104/2/1 |
|
Number of Input Channels |
16 independent channels |
|
Nominal Input Voltage |
24 Vdc |
|
Maximum Input Voltage |
36 Vdc |
|
Input Current |
7 mA at 24 Vdc |
|
Logic HIGH Threshold |
> 15 Vdc |
|
Logic LOW Threshold |
< 9 Vdc (I < 2 mA) |
|
Input Delay |
Typically 10 ms |
|
Power Requirements |
5 Vdc @ 1 mA; 24 Vdc int. @ 35 mA; 24 Vdc ext. @ 100 mA (input currents) |
|
Software Version Compatibility |
≥ge 3.00 |
|
Key Coding Slot Position |
Hole Position A5, Pin Position C21 |
|
Operating Temperature |
Standard industrial chassis thermal ratings |
|
Storage Temperature |
Extended industrial range |
|
General Approvals & Compliance |
CE, TÜV, UL |
|
Estimated shipping dimensions |
12.8x10x1cm |
|
Weight |
0.06kg |
|
Place of shipment |
Xiamen, China |
High-Density Channel Layout: The HONEYWELL 10104/2/1 provides 16 channels within a compact 4 TE / 3U Eurocard footprint, optimizing cabinet space.
Precise Signal Discrimination: Features well-defined switching thresholds (HIGH > 15 Vdc, LOW < 9 Vdc) to prevent false triggering from electrical noise.
Standardized Mechanical Coding: Incorporates exact physical key coding (A5 / C21) to safeguard against incorrect module placement in live system slots.
Integrates 16 un-tested digital input channels designed for standard 24 Vdc discrete signal collection.
Conforms to the 4 TE wide by 3U high modular eurocard physical standard for Honeywell FSC racks.
Low internal power consumption profile (5 Vdc @ 1 mA and 24 Vdc internal @ 35 mA).
Certified under CE, TÜV, and UL guidelines for global industrial deployment.
Application Scenarios
Industrial automation and discrete signal data acquisition systems.
Non-critical status monitoring panels within chemical, manufacturing, and energy processing plants.
Standard digital telemetry integration inside Honeywell FSC control architectures.
Monitoring & Control
Monitors up to 16 individual digital contact closures or 24 Vdc source signals simultaneously.
Communicates real-time channel input states directly to the core FSC processing units via the system backplane bus.
Utilizes fixed input delay characteristics (~10 ms) to filter out transient line noise before state evaluation.
Compatibility & Interoperability
Fully compatible with Honeywell Fail Safe Control (FSC) system racks and backplanes requiring 4 TE wide modules.
Designed to interface with system software versions 3.00 and higher.
Interoperates with standard 24 Vdc field transmitters, relay contacts, and discrete binary output instruments.
The HONEYWELL 10104/2/1 features sixteen 24 Vdc digital input channels that are un-tested, meaning they are strictly intended for general status monitoring and general-purpose control rather than fail-safe safety loops. Installers must verify that the system software version is 3.00 or higher and that physical key coding matches slot position A5/C21 before system power-up.
Q: Can the HONEYWELL 10104/2/1 be deployed in safety-critical ESD (Emergency Shutdown) safety loops?
A: No, because the input channels on the HONEYWELL 10104/2/1 are un-tested, they are restricted from being utilized for direct fail-safe safety applications.
Q: What are the exact voltage threshold limits for a HIGH signal on the HONEYWELL 10104/2/1?
A: A logic HIGH state on the HONEYWELL 10104/2/1 requires an input voltage greater than 15 Vdc.
Q: What software version is required to run the HONEYWELL 10104/2/1 properly?
A: The HONEYWELL 10104/2/1 requires system software version 3.00 or higher.
Q: How much physical slot space does the HONEYWELL 10104/2/1 occupy in a rack?
A: The HONEYWELL 10104/2/1 occupies 4 TE (4 HP) of width and 3 HE (3U) of height in a standard Eurocard chassis.
Q: What mechanical key coding configuration is assigned to the HONEYWELL 10104/2/1?
A: The HONEYWELL 10104/2/1 uses physical key coding configured at Hole Position A5 and Pin Position C21.
ABB: Industrial robot parts of DSQC series,Bailey INFI90, DCS
Honeywell: 51/MU/MC/TC/CC ...
Triconex: 3008/3511/3625/3664/3721/3700A..
Bently Nevada: 3500/3300/330180-Cable..
Foxboro: FBM203/204/217/231, FCP240/270
Woodward: SPC valve position controller, PEAK15 digital controller
Siemens: 6DD/6DP/6ES5/6DR/6GK Series
Westinghouse Series: 1C/5X ...
General electric: IC693/IC697/IC695/DS200..
Schneider: 140 Series