Allen-Bradley CompactLogix 5380 5069-L320ER 2 MB EtherNet/IP Controller | Original New

ALLEN-BRADLEY | CompactLogix 5380
5069-L320ER
CompactLogix 5380 2 MB EtherNet/IP Controller
Configuratio: 2 MB controller capacity | Up to 16 local I/O modules | No integrated motion | 40 EtherNet/IP devices
Tempus ducens: In stoce
Garantia: unum annum
Appurtenance:
  • Conspectus
  • Data Technica
  • Inquisitio
  • Proprietates
  • Interfacies
  • Installatio
  • Environment
  • Quaestiones Frequentes
  • Modellos Recommandatos
  • Producta commendata
Allen-Bradley CompactLogix 5380 5069-L320ER
2 MB EtherNet/IP Controller
Controller, CompactLogix 5380, 2 MB, 16 I/Os, 40 EtherNet/IP Devices. The controller uses the CompactLogix 5380 DIN-rail platform with integrated EtherNet/IP communications.
Capacitatem regolandi
2 MB and up to 16 local 5069 Compact I/O modules.
CONTROLLER ROLE
Standard controller catalog without integrated motion capacity.
Rete
Two EtherNet/IP ports and support for up to 40 EtherNet/IP devices.
Montatio
Horizontal DIN-rail installation; open-style enclosure.

Data Technica

Modello completo
5069-L320ER
Familia producti
CompactLogix 5380
Typus Producti
EtherNet/IP controller
SERIES
B
Capacitas controlleris
2 MB
Processor
Quad-core
Local I/O modules, maximum
16
Motus integratus
Nullus
EtherNet/IP devices, maximum
40
Built-in communication ports
2 EtherNet/IP ports; 1 USB port
Ethernet performance
10 Mbps, 100 Mbps, 1 Gbps; full duplex only
Modi EtherNet/IP
Dual-IP mode; Linear/DLR mode
Network topologies
DLR, stella et linearis
MOD Potentia tensio intervallo
18 ad 32 V DC
MOD Potentia currentis, maximum
450 mA
Potentia dissipatio, maximum
8,5 W
Dimensiones (A x L x P)
143.97 x 98.10 x 136.81 mm (5.67 x 3.86 x 5.39 in.)
Pondus, approximatum
0.768 kg (1.693 lb)
Montatio
Montage horizontalis in DIN-rail; EN 50022, 35 x 7.5 mm rail
Theca
Nullum; forma aperta
Temperatura operativa
0 ad 60 °C (32 ad 140 °F)
Temperatura non operativa
−40 ad +85 °C (−40 ad +185 °F)
Humiditas relativa
5 ad 95%, noncondensans
Certifications listed by manufacturer
China CCC, RCM, IECEx, ATEX, RINA and EAC

Proprietates

Capacitatem regolandi
The 5069-L320ER provides 2 MB controller capacity and supports up to 16 local 5069 Compact I/O modules with a four-core processor.
CONTROLLER ROLE
Standard controller catalog without integrated motion capacity. The model supports up to 40 EtherNet/IP devices.
EXECUTION MODEL
The controller supports 32 tasks, up to 1000 programs per task and continuous, periodic and event task triggers.
Memoria non volatilis
Rockwell Automation supports 1784-SD1 and 1784-SD2 Secure Digital cards. The 5069-ECR end cap is used at the right side of the system.

Interfacies

Portae Ethernet
Two EtherNet/IP ports operate at 10 Mbps, 100 Mbps or 1 Gbps, full duplex only.
NETWORK MODES
The ports support Dual-IP mode or Linear/DR mode. Supported topologies include device-level ring, star and linear.
Portus servitii USB
Unus portus USB 2.0 Typi B ad velocitatem plenam praebetur pro programmatione, configuratione, firmwaris inscribendis et emendationibus in linea tantum.
Connesiones Electricae
Potentia MOD et potentia SA utuntur separatim ordinatis catenis terminalium amovibilium 5069: 5069-RTB64-SCREW aut 5069-RTB64-SPRING.

Installatio

Installatio in lege DIN
Controllatorem horizontaliter in raile DIN compatibili zincato et ferro chromato ad normam EN 50022, 35 x 7.5 mm, monta.
Minima Discretio
Spatium liberum 50.80 mm (2.00 in.) omnibus lateribus serva ad 55 °C et 101.60 mm (4.00 in.) ad 60 °C.
CATENAE TERMINALES
Controllator non includit terminales amovibiles. Catenas 5069-RTB64-SCREW aut 5069-RTB64-SPRING pro connexionibus potentiae MOD et SA ordina.
COMPLETIO SYSTEMATIS
Install the 5069-ECR end cap on the right side of the last module before applying power. Use up to 16 local 5069 Compact I/O modules.

Environment

Temperatura
Intervalum operativum: 0 ad 60 °C (32 ad 140 °F). Intervalum non operativum: -40 ad +85 °C (-40 ad +185 °F).
HUMIDITAS ET INCLOSURA
Humiditas relativa est 5 ad 95% noncondensans. Controller est stili aperti et requirit idoneum clausuram pro installatione.
MECHANICAL ET EMC
Certificatus pro vibratione 5 g ad 10 ad 500 Hz, impulsu operativo 30 g et impulsu non operativo 50 g; emissiones conformantur IEC 61000-6-4.
RECORDA CERTIFICATIONIS
Pagina producti fabricantis recenset recorda certificationis China CCC, RCM, IECEx, ATEX, RINA et EAC. Conferre signa in exacta etiquetta unitatis pro data productionis supplicatae.

Quaestiones Frequentes

Q1. How can a buyer verify that the quoted controller is exactly 5069-L320ER?
A. Conformare numerum catalogi completum in etiquetta controlleris et in quotatione. Confirmare capacitatem 2 MB, maximum 16 modulos I/O locales, nullam motionem integratam, et limitem EtherNet/IP pro 40 dispositivis.
Q2. Quae indicia distinguunt unitatem novam 5069-L320ER ab unitate usata vel refabricata?
A. Petere imagines actuales tituli, habitaculi, duorum portuum Ethernet, portus USB pro servitio, regionis cartae SD et regionis terminalis electricae. Nova unitas debet habere consistentem confectionem fabricae et nullas notas installationis, connexionis aut manipulationis.
Q3. Quomodo fornitor 5069-L320ER examinari debet antequam ematur?
A. Verificare nomen legale societatis, registrationem, beneficiarium bancarium et verum locum commercii. Postulare quotationem scriptam quae identificet 5069-L320ER, eius conditionem exactam, probationem serialis, accessoria inclusa et condiciones reditus.
Q4. Quae valores technici inspiciendi sunt antequam 5069-L320ER ordinatur?
A. Confirmare potestatem MOD 18 ad 32 V DC, capacitatem 2 MB, duos portus EtherNet/IP, limitem pro 40 dispositivis, selectionem controlleris sine motione, maximum 16 modulos locales, dimensiones 143.97 x 98.10 x 136.81 mm et fixationem horizontalem in raeda DIN.
Q7. Quae probatio physica postulanda est antequam pecunia solvatur pro 5069-L320ER?
A. Petere photographias aut videos cum data inscripta, quae ostendant totam tabellam, numerum seriale, indicatores, portus, vasum, aream terminalis et confectionem. Confirmare an kitus terminalis 5069-RTB64-SCREW vel 5069-RTB64-SPRING inclusus est, quia terminalia removibilia separatim ordinantur.
Q6. Potestne alius suffix 5069 substituere 5069-L320ER?
A. Non tractare similem suffixum ut aequivalentem. Alii controlleres 5069 possunt differre in capacitate controlleris, facultate axis motus, limite dispositivi EtherNet/IP, capacitate localis I/O et functionibus securitatis. Substitutio requirit comparationem technicam completam et approbationem applicationis.

Modellos Recommandatos

DKC03.1-040-7-FW
T8461C
B 5X00453G01 Remote I/O Node Controller
ProSoft MVI69E-MBS
X20PS9402
T8850C
Yokogawa ATD5A
IC693MDL742
TDM4.1-020-300-W0
1783-BMS10CGP
16 ACS580-01-206A-4
PM591-2ETH
22B-B012N104
2711P-T12C4D8
TRICONEX 8312
VME162PA-344SE
160-BA04NSF1
CC-PCNT02
VersaMax CPU IC200CPUE05
Siemens 6ES7522-1BH10-0AA0
T8151C
2711P-T15C21D8S
X20SI4100
HDS03.2-W100N-HS32-01-FW
DS200LDCCH1A
3HAC058993-004
80190-100-01-R
22B-D6P0N104
ABB SD833
6 ACS355-03E-15A6-4
2711R-T10T
DS200DMCBG1A
2707-V40P2N
FC-UGAO01
IC655MDL527
Tricon 3008
DS200TCTSG1A
FCM2F4
DS200SDCCG1A
Yokogawa S2MMM843-SS1130
X-CPU 01
MVME61006E-0161
3HAC058612-00
F3 DIO 20/8 02
SPASI23
ProSoft PLX31-PND-MBS4
A 5X00419G02 Ethernet Link Controller
5466-1045
3HAC029896-001
5466-1245
1761-L32BWA
CMC16 200-530-022-014
HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW
B 1C31181G02 Remote I/O Module
RH916FN
5466-315
KDA3.3-100-3-A00-W1
TRICONEX 3636R
AI880A
Yokogawa AAI143-H50/K4A00

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000