KJ3001X1-BA1 belongs to the DeltaV M-Series traditional I/O 8-channel, 24 VDC isolated discrete-input card family. The official family data specifies eight optically isolated channels and defined input thresholds.
Procurement and installation checks must confirm the full legacy code, the matching terminal block variant, I/O card keying, 24 VDC field circuit, and M-Series carrier arrangement.
|
Res
|
Informatio officio comprobata
|
|
Modello completo
|
KJ3001X1-BA1
|
|
Nota
|
Emerson
|
|
Familia producti
|
DeltaV M-Series I/O traditionalis
|
|
Typus Producti
|
carta Input Discretus Isolatus 8-Canalis, 24 VDC
|
|
Numerus canalium
|
Octo
|
|
Typus Ingressus
|
24 V DC isolated discrete input
|
|
Isolatio Canalium
|
Each channel is optically isolated from the system and from the other channels
|
|
Factory isolation test
|
1500 V DC
|
|
Nivelis detegendi pro ON
|
Greater than 10 V DC
|
|
Nivelis detegendi pro OFF
|
Less than 5 V DC
|
|
Input impedimentum
|
5 mA ad 24 V
|
|
LocalBus current per card
|
75 mA typice, 100 mA maximum ad 12 V DC nominali
|
|
Potentia circuitus campi per cartam
|
Nullus
|
|
Fusibile opzionale
|
2.0 A
|
|
Aestimatio Protectionis
|
IP20 – specificatio communis interfacii M-Series I/O
|
|
Temperatura operativa
|
-40 ad 70 °C – specificatio communis interfacii M-Series I/O
|
|
Temperatura servandae
|
-40 ad 85 °C – specificatio communis interfacii M-Series I/O
|
|
Humiditas relativa
|
5 ad 95 %, non condensans
|
|
Dimensiones
|
A 10.7 cm × L 4.1 cm × P 10.5 cm – specificatio communis interfacii M-Series I/O
|
|
Pondus
|
Non separatim edita pro KJ3001X1-BA1 in documento officiali electo
|
|
Blocculus terminalem
|
Confirmare block standardem, fusum, vel massam 16-pin terminationem pro applicatione DI isolata.
|
|
Portans
|
Utere positionem correctam carrier M-Series pro interface I/O.
|
|
Circulus Campestriae
|
Verificare fontem campi 24 VDC et wiring canalis contra limites input.
|
|
Protectio optativa
|
Confirmare si applicatio utitur arrangemente fusorum optionalium 2.0 A.
|
|
Mapping antiquum/praesens
|
Non substituere combinationem VE ordinandi praesentem pro codice antiquo KJ sine approbatione ingeniaria.
|
|
Identitas citata
|
KJ3001X1-BA1 must appear in full on the quotation, card label, and physical evidence.
|
|
Electrical evidence
|
Confirm the 8-channel 24 VDC isolated DI profile and the specified thresholds.
|
|
Proof of termination
|
Obtain the proposed terminal block type, keying, and carrier configuration.
|
|
Probatio a supplerio
|
Verify company registration, business contacts, bank beneficiary, and traceable DeltaV references.
|
|
Inspectio liberationis
|
Before payment, reconcile model, quantity, condition, label, connector, terminal block plan, and any serial or lot data.
|
|
1756-PB72
|
6GK7542-5FX10-0XE0
|
1756-L902TS
|
|
6EP1133-4BA00
|
6ES7138-6EB00-0BA0
|
1756-L905TS
|
|
6AV6648-0DC11-3AX0
|
6ES7516-3FN00-0AB0
|
6ES7297-0AX30-0XA0
|
|
6ES7132-6HD00-0BB1
|
CI522-MODTCP
|
CM574-RS
|
|
9200-03-02-10-00
|
6GK1901-1BB10-2AA0
|
6ES7654-6YM00-7AF0
|
|
6FC5371-0AA30-0AB0
|
1769-L24ER-QB1B
|
1769-L24ER-QBFC1B
|
|
1769-L27ERM-QBFC1B
|
5069-L320ERMS2
|
1756-L61
|
|
1756-L63
|
1756-L75
|
1756-L85E
|
|
1756-L84ES
|
1756-IA16
|
1756-A4
|
|
1756-A7
|
6ES7231-7PF22-0XA0
|
6AG1321-1BL00-2AA0
|
|
6ES7138-6BA00-0BA0
|
6AU1445-2AD00-0AA0
|
6ES7216-2BD23-0XB8
|
|
VE3051C4
|
KJ2005X1-BA1
|
KJ4002X1-CA1
|
|
6ES7135-6HB00-0DA1
|
1769-L18ERM-BB1B
|
6GK5008-0BA10-1AB2
|
|
CM575-DN
|
5069-L310ER
|
1756-EN2T
|
|
6DL1155-6AU00-0PM0
|
TU516
|
21000-16-10-00-120-03-02
|
|
6ES7214-1AG31-0XB0
|
5069-L320ERM
|
1756-OF8
|
|
6AV2181-8XP00-0AX0
|
CM576-PNIO
|
6EP1933-2EC51
|
|
1756-IB16
|
6GK1900-0KB00-0AC0
|
VE3051C0
|
|
5069-L330ERMS2
|
6ES7526-1BH00-0AB0
|
1756-L82E
|
|
KJ2002X1-BA1
|
6ES7532-5HH00-0AB0
|
CM577-ETH
|