| VENDITE | Epistula electronica | Telephus WhatsApp |
|---|---|---|
| Iimus Pei | [email protected] | +86 18020776782 |
| Modellum | F8627 |
|---|---|
| Familia producti | H41q / H51q |
| Typus Producti | Modulus Communicationis Ethernet |
| Plateformes système | H41q / H51q |
| Functio Moduli | Communicatio Ethernet |
| Unités de hauteur | 3 |
| Canali Communicationis | 1 |
| Standard Ethernet | 100Base-T |
| Conector | RJ45 |
| Protocola | OPC DA / OPC A&E / safeethernet |
| Relatio substitutionis | Introduced to replace F8625 |
| ISOLATION NOTE | No isolation between input and output sections |
| Temperatura superficiei maxima | 51.1°C |
| Classis temperaturae | T5 |
| Product Dimensiones | 2 × 18.5 × 12.8 cm |
| Pondus | 0,14 kg |
| Minimum quantitas ordinis | 1 piece |
|---|---|
| Pretium | Contactus pro Jim |
| Singula Packaging | Novus Originalis, Sigillatus a Fabrica |
| Tempus Traditionis | 3–7 dies |
| Condiciones solutionis | T/T |
| Shipping modum | DHL / FedEx / UPS / TNT |
| Capacitas Supplicandi | Novus prorsus, in stock |
Matched as a HIMA Ethernet communication module, F8627 belongs to the H41q / H51q platform. It provides one 100BASE-T Ethernet interface for the H41q and H51q safety platforms. The model-specific arrangement supports safeethernet together with OPC Data Access and OPC Alarm & Event communication. Its installed interface was introduced as the Ethernet-capable replacement for the earlier F8625 communication module. These characteristics define the exact hardware boundary that must be matched when the component is sourced for an existing system.
For asset continuity, F8627 supports safety peer exchange while maintaining the documented opc plant supervision path. The component is especially relevant where engineering communication must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern legacy ethernet migration. Requires the documented operating mode, IP parameters and safety communication configuration to be restored. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.
| ULXP4, 829-865 | JZ10-11-PT15 | DUS360CR |
| CS540 | ABB AI531 / 1SAP250600R0001 | LV429634 NSX100F |
| HLBGK2 | WTR1-P421S08 | MT52330BB |
| UC-5011 | MR380 | AAM11 |
| KFD2-GS-1.2W | ABB RXMB 1 1MRK 000 863-AN | ABB 2CDG110060 R0011 |
| 3RT1046-1AL20 | K9800EE GC8000 | CA20CE |
| MR-4 | DDRC810DT-GL | ABB DC551 / 1SAP220500R3001 |
| 3-PPS/M-230 2990108 | CARBON 1-22 | D-67722, MX-SM-D25-PW |
| D-67722, MX-SM-N160-LPF-PW | DRT1-ID16 | XFL523B |
| PA-699-04-V | 6ED1055-1MD00-0BA2 | H2EWXBBL57D |
| CAB 5004 | ABB RXMC 11 MRK000660-AN | ABB 1SVR730180R3100 |
| EPP301 | KMD-1161W | AI810 |
| 2641005WD11A1C DPT2641-005D-1 | 6ES7195-7HB00-0XA0 | 6ES7157-0AA82-0XA0 |