Siemens 6ES7157-0AG83-0XA0 SIMATIC AFDiS Active Field Distributor

Nomen producti: SIMATIC AFDiS Active Field Distributor
Nomen Marcae: Siemens
Numerus Modeli: 6ES7157-0AG83-0XA0
Locus Originis: Germania
Garantia: 12 Mensis
Whatsapp: +86 18020776782
Inscriptio electronica: [email protected]

Appurtenance:
  • Conspectus
  • DESCRIPTIO
  • Instauratio et Integratio
  • Specificationes
  • Commercial Term
  • Securitas et Conformitas
  • INFORMATIO CONTACTUS
  • Quaestiones Frequentes
  • Other Products
  • Producta commendata
Intrinsically safe field distribution for PROFIBUS PA and FOUNDATION Fieldbus H1
The Siemens SIMATIC AFDiS combines a FISCO field barrier, six short-circuit-proof spur lines, an integrated fieldbus repeater and automatic line or ring termination in an IP66 field enclosure.
Before you order: Confirm the installed segment concept, hazardous-area documentation, spur count and whether the system uses line or Siemens-approved ring redundancy before ordering.

DESCRIPTIO

Hoc est dispositivum distributivum activum ad usum in plantis pro processibus, quod connectit instrumenta intrinsece secura ad segmentum PROFIBUS PA vel FOUNDATION Fieldbus H1, simul singulas defectus in ramis isolans.
Repetitor integratus et logica protegens contra rimam (bounce-protection) favent operationi stabilis fieldbus. Terminatio automatica simplificat topologias lineares et anulares, sed installatio completa adhuc debet sequi designatum arearum periculosarum et dispositions de terrae connexione.

Instauratio et Integratio

Tracta totum segmentum fieldbus ut unum systema technice concinnatum.
Designatio segmenti
Verifica tensionem trunci, oneramentum rami, typum cavi, scutum, connexionem ad terram, et approbationes pro areis periculosis antequam distributor substituatur.
Commissioning anuli
Siemens affirmat redundancy anuli esse approbatam cum componentibus rete Siemens; testa comportamentum interruptionis et cortocircuitus cavi antequam productio liberetur.
Praxis circa clausuram
Serva hermeticitatem specificatam IP66, glandulas cavi, et installationem operculi post connexionem vel inspectionem.

Specificationes

Designatio generis producti
SIMATIC AFDiS active field distributor
Numerus ordinis
6ES7157-0AG83-0XA0
Usus bus campi
PROFIBUS PA aut FOUNDATION Fieldbus H1
Connexiones spur
6 lineae spur breviter-circuitorum-proof, intrinsece securae
Functiones Integrae
Barriera campi FISCO, repetitor et logica protectionis contra rimam
Supportus topologiae
Topologia linea aut anularis approbata a Siemens
Terminatio Bus
Automaticum
Gradus praesidium
IP66
Status producti
Descripta; successor Siemens disponibilis
Successor officialis
6ES7655-5DX60-1BB0

Commercial Term

Praeoffertio
Pretium praesens et disponibilitas
Solutio
T/T aut condicionibus conventis
Tempus praecedens
Confirmatum cum citatione
Navigatio
DHL, FedEx, UPS aut oneribus conventis
Garantia
12 Mensis

Securitas et Conformitas

Commissioning debet fieri a personis qualificatis utentibus documentis plantae approbatis.
Circuitus intrinsece securi
Ne mutare dispositiva spur neque methodos connexorum antequam compatibilitas entitatis vel FISCO confirmata est.
Testum defectus
Antequam operatio incipiat, simulare permittendam interruptionem bus et curtum circuitum spur et confirmare responsionem plantae intentam.
Probatio substitutionis
Notare exactum numerum ordinis, classificationem zonae et schemata segmenti pro citatione et acceptance.

INFORMATIO CONTACTUS

Quaestiones Frequentes

Q1
Quomodo verificare possum an 6ES7157-0AG83-0XA0 idoneus sit pro segmento fieldbus in area periculoza iam existente?
Comparare schemata segmenti, typum fieldbus, tensionem trunci, parametra FISCO vel intrinsic-safety, requisitum sex spur et locum clausurae cum systemate installato. Suspendere revisionem substitutionis si documentatio approbata pro area periculoza non adhibetur.
Q2
Quid testare debet post installationem 6ES7157-0AG83-0XA0 in topologia anuli?
Commissionare segmentum cum planta in statu tuti, deinde probare casus approbatos interruptionis et cortocircuitus cavi. Confirmare communicationem manere ut designatum est et comportamentum diagnosticum congruere cum actis systematis de controllo.
Q3
Cur unum dispositivum campestre manet offline postquam 6ES7157-0AG83-0XA0 excitatur?
Inspicere spurium affectum pro polaritate inversa, cortocircuito, terminalibus laxatis, longitudine excesiva cavi et parametris securitatis intrinsecae incompatibilibus. Comparare impetum currentis dispositivi et tensionem segmenti cum calculo ingenierii antequam hardware substituatur.
Q4
Quid inspicere debes quando communicatio per 6ES7157-0AG83-0XA0 fit intermittens?
Ins picere scutum trunci et spuri, terram, glandes cavi, ingressum umoris, conductores laxos et qualitatem potestatis. Notare an defectus sequatur unum spurium an afficiat totum segmentum, deinde recensere diagnostics fieldbus.
Q5
Quomodo gradum IP66 protegere debes dum 6ES7157-0AG83-0XA0 servitur?
Isolate the plant according to site procedure, use approved glands and seals, keep mating surfaces clean and refit every cover correctly. Perform the site-required enclosure inspection before returning the segment to service.
Q6
What information should I provide when requesting a replacement for 6ES7157-0AG83-0XA0?
Provide the full order number, hazardous-area classification, fieldbus type, topology, connected spur count, installed Siemens components and photos of the terminal arrangement. Also state whether evaluation of the listed successor is acceptable.

Other Products

DM04A02KNX
TP-10
711-026017 R07
CLR96 946040
CSE-200
500-003087-TK0
59646
XD26 88974163
ABB PNU32.0 / 1SAJ263000R0100
PFD-402-25
020/A
IC697MEM713B 44A726846-001R04/5
HAMBURG GVAG-2VK1S
EBR-DIN-LCM5-5
PCoeccrs10 W3000
AE02 8000022185
03031-3023-0022
5WG1 140-1AB13
QL420 Q4D-LUBCE011-00
NetAgent9 BX506
R4343D1017
PCoeCVRS10 W3000
6ES7431-0HH00-0AB0
BK9053
ARU2-CON-RM A1120130
CPM-51-A1V5-I-2-NN-AD
1AK23148AAAA
751366 220-751366-401
ATD5D-00
RR1A03AEB00

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000