Minimum quantitas ordinis |
1 piece |
Pretium |
Contactus pro Jim |
Singula Packaging |
Novus Originalis, Sigillatus a Fabrica |
Tempus Traditionis |
3–7 dies |
Condiciones solutionis |
T/T |
Shipping modum |
DHL / FedEx / UPS / TNT |
Capacitas Supplicandi |
In stoce |
|
Numerus Exemplaris
|
6SL3210-5HE10-8UF0
|
|
Fases inputus
|
3 CA
|
|
Voltus Lineae
|
200–480 V ±10%
|
|
Frequentia Lineae
|
45–66 Hz
|
|
Evaluatus Input Correntia
|
2,8 A
|
|
Potentia nominalis ad 400 V
|
0.75 kW
|
|
Potentia nominalis ad 240 V
|
0.45 kW
|
|
Fases outputus
|
3 CA
|
|
Currentis Output Aestimatus
|
2,3 A
|
|
Currentia maxima emissa
|
7.6 A
|
|
Pulsus frequency
|
8 kHz
|
|
Frequentia Exitus Servi
|
0–550 Hz
|
|
Alimentatio Electronica
|
24 V DC, -15% / +20%
|
|
Maxima Currus Electronica
|
1,0 A
|
|
Current surge in electronics
|
4,3 A
|
|
Communicatio
|
Profinet
|
|
Temperatura operativa
|
0–50 °C
|
|
Temperatura servandae
|
–25 à +55 °C
|
|
Trānsportus temperatūra
|
−40 ad +70 °C
|
|
Operativus Relativus Umor
|
95% maximum, non-condensing
|
|
Altitudo installationis sine reductione
|
1000 m
|
|
Refrigerans
|
Air cooling with integrated fan
|
|
Protection
|
IP20 / UL apertum typus
|
|
Magnitudo Frami
|
FSA
|
|
Maximum Shielded Motor Cable
|
50 m, external-filter conditions apply
|
|
Braking resistor cable length
|
10 m
|
|
Line terminal conductor range
|
0.75–6.00 mm² / AWG 18–10
|
|
Motor terminal conductor range
|
0.75–6.00 mm² / AWG 18–10
|
|
Braking terminal conductor range
|
0.75–6.00 mm² / AWG 18–10
|
|
Ingressus Digitales Normales
|
5; duo adhibentur pro F-DI
|
|
Fail-Safe Digital Inputs
|
1, solum pro STO/SS1
|
|
Nivelis Integritātis Securitātis
|
SIL 2
|
|
Gradus operationis
|
PL d, Categoria 3
|
|
Constructio terminalis
|
Terminalia molla ad inserendum
|
|
Origo installationis
|
Montatio verticalis in parietem
|
|
VENDITE
Iimus Pei
|
Epistula electronica
|
Telephus WhatsApp
|
Siemens 6SL3210-5HE10-8UF0 est conversor servus SINAMICS S210 cum communicatione PROFINET. Potentia nominalis motoris eius est 0.75 kW ad 400 V. Conversor accipit alimentationem trifasiam in intervallo specificato. Alimentatio DC separata impellit electronica. Unitas praebet output trifasium regulatum pro systemate servorum compatibili.
Conversor integratur in applicationem motus configuratam per PROFINET. Ingressus digitales normales suffragantur signa imperii localia. Ingressus fallax-salus destinatus est tantum ad functiones STO et SS1 enumeratas. Terminalia molla ad inserendum praebentur pro connexionibus potestatis documentatis. Elige calembum motoris, dispositionem freni et configurationem salutis pro installatione reali.
|
PC0904-21 HWS600-48 CLAXEH00ND100A
IRDH275-435 E244-16C-G-LS-SN-CR-SQ-BR U30IPGWZB
PP056TB1-113 AKM115F120 PCD7.D230
PC-E984-265 VCL-E1-030 CAN-5901
EW300 PSI-MOS-RS232/FO PCS090 PG090.205.B
ECC-301 SN3101 CRT341
PX-Q120 TE500CW12D2A1E2 HWS600-24
EY-IO551F001 KFDO-HMS-16 HHC12WM
AVAYA 700283690 6029493 PG320240WRT-MNN-IQ E5504GI
BT-F420 MTL4513 PT100 ICP22JI750000
ZA10341 67DFR / LOC477 / 250PSI / 0-60PSI JAMSC-B2505
UCS-52 6MBI300U4-120-01 KFD2-UT2-1 191884
BIP-5000 WV-CP504E AC2410
|