Modello completo
|
6ES7193-6BP60-0DA0
|
|
Familia producti
|
SIMATIC ET 200SP BaseUnits
|
|
Typus Producti
|
2-fold BaseUnit type A0, light-dark version, without AUX terminals
|
|
Dimensiones
|
30 x 117 x 35 mm (W x H x D)
|
|
Pondus
|
Approximately 80 g
|
|
Breve designatio
|
2BU15-P16+A0+2DB
|
|
Supple voltage
|
24 V DC
|
|
Protectio Externa
|
24 V DC / 10 A interruptor automaticus minimus, characteristica B vel C
|
|
Filtrum principalis
|
Integrated
|
|
Capacitas bus P1 et P2
|
Maximum 10 A
|
|
Capacitas terminalis processus
|
Maxime 2 A
|
|
Gruppus potentialis
|
Novum gruppus potentialis: ita; continuatio ab sinistra: non
|
|
Examen Isolationis
|
examen typicum 707 V CC
|
|
Terminalis genus
|
Ad insertionem
|
|
Intervalum conductorum
|
0,14 ad 2,5 mm²; AWG 26 ad AWG 14
|
|
Terminales processuales
|
16 per scissuram
|
|
Terminalia P1 et P2
|
2 per scissuram
|
|
Terminales auxiliares
|
Nullus
|
|
Temperatura operativa
|
0 ad +60 °C horizontaliter; 0 ad +50 °C verticaliter
|
|
Altitudo Operationis
|
Maximum 2 000 m
|
|
Compatibilia Modula
|
Moduli I/O pro BaseUnit typi A0 aut A1
|
|
BaseUnit duplex
Hoc congeries unum levis 15 mm BaseUnit A0 et unum obscuri 15 mm BaseUnit A0 combinat.
|
Gruppatio potentialis
Latus levis novam gruppationem potentialis incipit, latus autem obscurum eam ad secundum locum portat.
|
|
Module Support
Utraque positio modulos I/O, qui pro BaseUnit typi A0 aut A1 identificati sunt, recipit.
|
Nulla terminalia AUX
Autobus AUX integratus nullum accessum terminalium in hac versione habet.
|
|
Terminales ad inserendum
Processus conductoribus per terminalia ad inserendum connectuntur.
|
Intervalum conductorum
Sectiones transversae conductorum admissoe sunt 0.14 ad 2.5 mm², AWG 26 ad AWG 14.
|
|
Puncta processus
Sedecim terminalia processus disponibilia sunt pro quolibet loco moduli I/O.
|
Bus electrici
P1 et P2 duo terminalia connexa pro quolibet loco praebent.
|
|
Initium potentialis
Partem claram collocare ubi novum gruppus potentialis incipere debet.
|
Supply Protection
Utere specificato interruptore circuitus 24 V DC / 10 A cum characteristicis B vel C.
|
|
Limites currentis
Bus P1/P2 retinere ad aut infra 10 A et singula terminalia processus ad aut infra 2 A.
|
Modulus inspicio
Confirmo quod inserti moduli I/O requirunt BaseUnit typi A0 aut A1.
|
|
Horizontalis montatio
Specifica temperatio operativa est 0 ad +60 °C.
|
Montatio Verticalis
Specifica temperatio operativa est 0 ad +50 °C.
|
|
Altitudo
Specifica altitudo installationis est usque ad 2 000 m supra mare.
|
Isolatio
BaseUnit est probatus in tensione 707 V DC.
|
|
Q1. Quomodo verificare possum quod citatum articulum est exacte 6ES7193-6BP60-0DA0?
Confer numerum totum articuli in citatione, notam in BaseUnit, et imballagium. Confirmo 2BU15-P16+A0+2DB, dispositionem duorum locorum (clarum-obscure), typum A0, nullas terminales AUX, et novam functionem potential-group.
|
|
Q2. How can I distinguish New, Used, or Refurbished condition?
Petere photographemas recentes tituli, utriusque positionis BaseUnit, terminalium push-in, contactuum bus, arearum codificationis, punctorum clausurae, corporis, et imballagii. Observa signa insertionis, contactus laesos, aut plasticum reparatorium.
|
|
Q3. Quomodo verificare possum ut venditor sit legitimus et fidus?
Verificare registrationem societatis, adressem, beneficiarium bancarium, contactus commerciales, et citationem formalem quae nominat 6ES7193-6BP60-0DA0 integre, cum conditione, quantitate, et photographematis traciabilibus.
|
|
Q4. Which specifications should an engineer verify before purchase?
Confirm the light-dark potential-group arrangement, A0/A1 module compatibility, 24 V DC supply, 10 A P1/P2 limit, 2 A process-terminal limit, push-in wiring, 30 x 117 x 35 mm dimensions, and 80 g weight.
|
|
Q5. What physical evidence should I request before payment?
Ask for dated images or video of the complete 6ES7193-6BP60-0DA0 marking, light and dark halves, all push-in terminal positions, P1/P2 contacts, coding features, packaging labels, and quantity.
|
|
Q6. Can two separate BaseUnits replace this 2-fold model?
Do not assume a direct replacement. Siemens identifies the product as a specific light-dark 2-fold BaseUnit; any substitute must reproduce the new-potential-group arrangement, terminal access, A0/A1 compatibility, dimensions, and current limits.
|
|
860-100-147LF 830-100-140LF
|
6ES7232-4HB32-0XB0
|
AIP602-S2
|
|
ST-IO ZA10341
|
D454 201-928.CE.P
|
DIA-2Q -352
|
|
ABB HS/S3.1 GHQ6050063R0001
|
9319400100 BE3-27/59-1A1N3
|
ABB 6197/52-101-500
|
|
F261MAH-V01
|
DBG11B08
|
CP17970
|
|
SMC5500/S
|
ABB 1MRK000508-BDr03 RL 1MRK000007-7 508-BDD
|
AM40
|
|
IC200UEM001
|
4-20MA/4-20MA/12-42DC
|
GJD-03R
|
|
TCESU083FN0
|
I350-T2 I350T2V2BLK
|
B0139CZ
|
|
XW582
|
KFD2-STC4-EX1-KFD2-STC4-EX1-KFD2
|
AAI135-H00 ATK4A-00-S1
|
|
FERMAX 2425
|
LD28-F1-3974/76a/112
|
MTN645094
|
|
821-DC-TCX
|
LS2D-30-0001PR
|
XF823A XS824-25
|
|
025L03042-00
|
SPCE652,000
|
LT-840-350
|
|
C320KGS42
|
ALF111-S01 S1 FF-H1
|
231C
|
|
009SMA2
|
Trio-PS-2G/1Ac/24DC/10
|
SR3 B261FU
|
|
DR4208SGM
|
METSEPM5560 PM5500
|
1606-XLS480EE
|
|
PCB00259-02
|
SSB401-13-S1
|
KS1-20B
|
|
LONWORKS
|
2RMLG 2993H10063D
|
ABB CTRLON4S240
|
|
MR-4
|
B401
|
ABB CP-24/1.5
|
|
S35S02A
|
DP-LBF-I1.36.IE
|
EL2271 PT100CLA
|
|
HLBGK2
|
EASY618-DC-RE
|
ABB 8104-500
|
|
3-PM-IO-INV
|
DI-8 02-5B-7F-BB-51-00
|
39M5411
|