Product Name:Carrier Extender, Left-hand
Brand Name: GE
Model Number:8021-CE-LH
Country of Origin:USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
General Electric |
Model Number: |
8021-CE-LH |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Model |
8021-CE-LH |
|
Manufacturer |
GE / Emerson (MTL) |
|
Product Type |
Left-hand Carrier Extender |
|
Product Family |
PAC8000 Remote I/O System |
|
Railbus Carrier Connector |
|
|
Extender Cable Connector |
|
|
System Power Cable Connections |
|
|
System Power Cable Conductor Size |
|
|
Usable with |
|
|
Maximum Extender Pairs per Node |
|
|
Mounting Method |
|
|
DIN Rail Types |
|
|
Dimensions (W × D × H) |
|
|
Weight |
|
|
Carrier Moulding Material |
|
|
PCB Material |
|
|
Operating Temperature |
|
|
Storage Temperature |
|
|
Relative Humidity |
|
|
Hazardous Area Approvals |
|
|
Protection Class |
|
|
Lifecycle Status |
Active |
The 8021-CE-LH is a left‑hand carrier extender from GE/Emerson‘s PAC8000 series, engineered to physically and electrically bridge separate I/O carrier runs within a distributed control system. The 8021-CE-LH pairs with its right‑hand counterpart, the 8020-CE-RH, to extend both the Railbus communication bus and system power across multiple carriers. With a rugged polycarbonate housing and integral DIN‑rail fixings, the 8021-CE-LH provides a male Railbus connector and a 37‑pin Sub‑D extender cable interface. Supporting up to three extender pairs per node and 32‑/64‑slot addressing, the 8021-CE-LH enables scalable, high‑density I/O architectures for demanding industrial automation environments
Industrial Process Control – Expanding I/O capacity in large‑scale distributed control systems (DCS)
Hazardous Area Installations – Suitable for Class I Division 2 and Zone 2 classified locations
Modular System Configurations – Facilitating the addition of carriers in complex automation setups
Retrofit & Upgrade Projects – Enabling scalable system growth without replacing existing PAC8000 infrastructure
Remote I/O Networks – Extending Railbus communication and power across physically separated I/O racks
Railbus & Power Continuity – Ensures seamless Railbus communication and power supply continuity between separate carrier runs
Left‑Hand Configuration – Designed as the left‑hand side of a carrier extender pair; pairs with right‑hand counterpart 8020‑CE‑RH
Male Railbus Connector – Provides a male‑out Railbus carrier connector for interconnection
37‑Pin Sub‑D Extender Cable Interface – Standardized connector for reliable multi‑way cable linking
6‑Terminal System Power Block – Screw terminals for HVCC+, HVCC‑, and SGND connections
Integral DIN‑Rail Mounting – Compatible with Top hat (EN 50022) and G‑section (EN 50035) rails
Hazardous Area Certified – Approved for Class I Division 2 / Zone 2 installations
Compact Form Factor – 42 mm width saves valuable cabinet space
True ‘Plug‑and‑Play’ Expansion – Unlike passive connectors, the 8021-CE-LH actively maintains Railbus signal integrity and power distribution across extended distances, enabling transparent system growth without complex reconfiguration.
Scalable Distributed Architecture – Supports up to three extender pairs per node and both 32‑slot and 64‑slot addressing, making it suitable for large‑scale PAC8000 installations with thousands of I/O points.
Rugged Industrial Design – Withstands extreme temperatures (–40°C to +70°C) and vibration, making it suitable for harsh environments such as oil refineries and chemical plants.
Global Hazardous Area Approvals – Certified for Class I Division 2 / Zone 2, simplifying deployment in explosive atmospheres worldwide.
Cost‑Effective System Growth – Enables adding remote I/O drops without replacing existing controller infrastructure, significantly reducing hardware, wiring, and commissioning costs
Q1: What is the primary function of the 8021-CE-LH?
A1: The 8021-CE-LH is a left‑hand carrier extender for the PAC8000 I/O system. It extends the Railbus communication bus and system power across separate I/O carrier runs, enabling scalable, distributed control architectures.
Q2: What is the difference between the 8021-CE-LH and the 8020-CE-RH?
A2: The 8021-CE-LH is the left‑hand carrier extender with a male‑out Railbus connector, while the 8020-CE-RH is the right‑hand counterpart with a female‑in Railbus connector. They are used together as a pair to link separate carrier runs.
Q3: How many extender pairs can be used per PAC8000 node?
A3: A single PAC8000 node supports a maximum of three extender pairs (three 8021-CE-LH + three 8020-CE-RH).
Q4: Is the 8021-CE-LH suitable for hazardous area installations?
A4: Yes. The 8021-CE-LH is certified for Class I Division 2 / Zone 2 hazardous locations with T4 temperature classification.
Q5: What addressing capabilities does the 8021-CE-LH support?
A5: The 8021-CE-LH supports both 32‑slot and 64‑slot addressing, providing flexibility for different system configurations and I/O density requirements.
Inquiry Now: [email protected]