GE Mark Vle

Safarada >  Maltid >  GE >  GE Mark Vle

GE Mark VIe IONet Ethernet Switch IS420ESWAH3A Marka La Hayo

Magaca Alaabta: IYO Net Switch Ethernet

Magaca Brand: GE

Lambarka Modelka: IS420ESWAH3A

Dalka kaleyska: Dhalinyarada Amerikanka

Damaanad: boqortooyada 12 Bulsho

Whatsapp: +86 18159889985

Iimaylka: [email protected]

Appurtenance:
  • Faahfaahin
  • La xiriir ku saabsan qorshaha
  • Xoggaarka
  • Sharaxaad
  • Codsiyada
  • Saxda ah
  • Funkushenaha
  • Dhibaatooyinka soo galay
  • Bixiyo Oo La Sameeyo

Faahfaahin

Magaca Brand:

General Electric

Lambarka Modelka:

IS420ESWAH3A

Dalka kaleyska:

Dhalinyarada Amerikanka

Furaha Talaalada:

Cusub oo ah orijinaalka, oo ku dhaqmayn khasabta ah

Wakhtiga aad ugu yaraysid:

Wakhtiga soo guurinta marka la jirto magaalo

Shurtida Casirada:

T/T

La xiriir ku saabsan qorshaha

Mudirka Biyaha:

Stella

Ii email:

[email protected]

Xiriirka WhatsApp:

+86 18159889985

Xoggaarka

Meesha

Faahfaahinta

ISIMKA QOOR

IS420ESWAH3A

Sameynta

General Electric (GE) / GE Vernova

Taxane

Mark VIe / Mark VIeS Speedtronic

Nooca Qaabka

Qaab la'ayn karo ah ee IONet Ethernet Switch (qoraal ESWA)

Kuwa Koperka

8 × 10/100Base-TX RJ45 (Auto-negotiation, HP-MDIX auto-sensing)

Kuwa Fiiberka

0 (qaab la'ayn karo ah ee dhinaca copper; ma jiro uplinks ee fibre)

Qaybta Badbaadinta

Ku dhaqan iyo ku dhaqan oo dhan

Bokska La Ilaaliyey ee Buufar

256 KB

Codka MAC

4,000 qoraal

Kuwa Xogta Shacabka

IEEE 802.3, 802.3u, 802.3x

Kontur yar-yar

IEEE 802.3x pause frames

Sincronisasiyaha Waqtiga

IEEE 1588 PTP (≤ 1 µs precision)

Kuugu Soo Dirir

24/28 V DC oo la isku dhex galka (18–36 V range), diode-OR’d

Kuwa Badan ee Ku Daray

1 A @ 24 V DC

Xirfadda caynaha

5 W taasirka, 8 W ugu badan

Ku jirka Dhexdooda ee Kala Bixinta

Xaqa xadgudub (ka yar marka 200% ee kuwa caadi ah)

Caano Caano

–40°C ilaa +70°C

Dhammaadka ammarta

–40°C ilaa +85°C

Cuneeynta

5% – 95% RH, aan ku jiro in la kululayo

Qaboojin

La'aa fan, ku dhaqaaqay in kuu soo saaray

MTBF

Ku jira 4 milyan saac oo ka badan @ 35°C

Muddo Xagga Dhexe

G3 ku dhaqaaqay in kuu soo saaray, ku xidhiidhaya in la galo karo dhulka

Kala joojin

1500 Vrms ku dhaqaaqay in kuu soo saaray-ku dhaqaaqay in kuu soo saaray

Qaybaha (W × D × H)

14x9.2x5.8cm

Miisaanka

0.52kg

Socod

DIN rail (35 mm) ama ku dhaqaaqay in kuu soo saaray

Tasdiqka Goobaha Xun

Qayruxa 1, Qayruxa 2, Kooxaha A-D; ATEX Goobaha 2; IECEx

Sertifikeedka Amniga

IEC 61508 SIL 2

Tixgelinta

CE, UL 508, RoHS

Dalka guurka

Maraykanka

Tixgal

Jira (cusho / la cusboonaysiiyey)

Sharaxaad

Waxaa IS420ESWAH3A waa isku daynta Ethernet iyo qalabka shaqo oo aan la isticmaalin karo copper (koper) ka mid ah, oo loo dhisay si guud ahaantii ku saabsan platformada xiriirka turbinada Mark VIe iyo Mark VIeS Speedtronic ee GE. Loo dhisay si guud ahaantii ku saabsan IONet (Shabakadda Dhexe ee Shaqo), IS420ESWAH3A wuxu leedahay 8 portada copper 10/100Base-TX RJ45, oo leh hab dhafayn ah ee xaqiijinaya xariirka, xaqiijinaya MDIX crossover, iyo xoolooyinka IEEE 802.3x ee daryeelka. IS420ESWAH3A wuxu qaataa portada fibre ee aan la isticmaalin karo, waxaana ka saaray xadigga ay ugu jiro inay ku jiro xadigga ay ugu jiro oo ka saaray shabakadda xiriirka dhexe ee ku saabsan qalabka xiriirka. Sida la eegayo xariirka 24/28 V DC ee laba kaliya, xoolooyinka aan la isticmaalin karo, iyo xariirka oo ka yimid –40 °C ilaa +70 °C, IS420ESWAH3A wuxu siiyaa isku daynta oo leh xariirka wadaag ah iyo xariirka ka yimid ka badan oo ku saabsan xiriirka turbinada I/O ee xaqiijinta waqtiga, oo ku saabsan goobaha xun ee ku saabsan daryeelka nabad gacmaha.

Codsiyada

  • Shabakadda xiriirka dhexe ee copper (koper) ee ku saabsan qalabka xiriirka turbinada gas iyo steam ee Mark VIe

  • Isdhexeeshka IONet backbone ee la isticmaalo in lagu xidhiido UCV controllers, I/O packs ku dhow, iyo local HMIs

  • Shabakadda xadgudubka industriya ee ka yar oo ay isticmaalaan copper cabling iyo aan ujeeddo in lagu isticmaalo fibre uplinks

  • Wadaagga xadgudubka aad ugu wanaagsan (Class I Div 2 / ATEX Zone 2) oo leh enclosures sax ah

  • Isku daynta shabakadda xadgudubka qaddeed ee loo baahanyahay switch unmanaged oo fudud iyo mid ka wanaagsan oo keliya

  • Wadajaha petrochemical iyo refining ee loo baahanyahay power redundant iyo communication deterministic

Saxda ah

  • 8 port copper oo ka badan: Laba astaan 10/100Base-TX RJ45 ee laba astaan ku jira waxay sameeyaan isdhexeeshka la xiriirka I/O packs, controllers, iyo HMIs ee ku jira local control cabinets; waxay ku dhaqaaqdaan port fiber ee aan isticmaalin ama la isticmaalo in lagu xisbiyo cost material iyo xadgudubka la xiriirka.

  • Dhisidda copper kaliya: Maya fibre uplinks — waxay sii xuruufa installtion iyo maintenance ee shabakadda xadgudubka ka yar, waxay xisbiyaan space cabinet iyo number of components.

  • Hawlaha unmanaged plug-and-play: Laa xeedhin karin in la sameeyo IP addressing, VLAN configuration ama network management; waxa uu ku guulaystay GE si loo sameeyo IONet traffic profiles ee real-time ee la xariiro leh.

  • Dhismaha laba joojinta 24/28 V DC ee dhismaha laba joojinta: Labo dhismaha joojinta la isku mid ah (TB1, TB2) oo leh diode-OR’d architecture; failover oo dhan oo isku daynaya marka joojinta ka duwan yahay, si loo hubiyo in shakhsiyaadu ugu dhaqmeysa.

  • Soo galka store-and-forward oo la xidhiidha xoolooyinka xoolooyinka: bufferka 256 KB iyo IEEE 802.3x pause frames ayaa ugaagaanaya in packet collisions iyo buffer overflow ka dhacdo, si loo hubiyo in data ay la xariiro leh ugu dhaqmeysa.

  • jadwalka MAC addresska 4,000: Waxa ku saabsanaya shakhsiyaad dheer oo leh I/O nodes, controllers, iyo HMI devices oo badan, laakiin ma aqbalin kara in qalabka ku dhaqmeysa.

  • Xoolooyinka soft-start ee kuwa soo galiya: Waxa ku xidhiidha inrush current si ay ugu yar tahay 200% ee inrush current ee caadi ah, si loo hubiyo in joojintada dhexeeya ay ugu dhaqmeysa marka shakhsiyaadu la bilaabo.

  • Gacanta sare ee gaarka ah ee shaqaynaya: 40 °C ilaa +70 °C qaboojinta convection-ka oo aan lahayn hawo iyo dahaarka G3 ee u dhigma iska caabbinta daxalka, oo lagu tijaabiyay ceeryaamo cusbo ah.

  • La isticmaalay goobta xadgudubka: UL Class I, Division 2, Group A-D; ATEX Zone 2; IECEx ku habboon in lagu isticmaalo jawiga qaraxa leh oo leh qol ku habboon.

  • IEC 61508 SIL 2 oo leh heerka badbaadada: Waxaa loo caddeeyay in loo isticmaalo nidaamyada qalabka badbaadada (SIS) ee u baahan in la waafajiyo amniga shaqada.

  • LED diagnostics ee leh qoraal badan: LED-yada laba-midab leh ee dekedda waxay bixiyaan jawaab celin muuqaal ah oo degdeg ah oo ku saabsan joogitaanka xiriirka, waxqabadka (cagaarka dhalaalaya = buuxa oo buuxa, huruud dhalaalaya = nus-duuxa), xawaaraha (cagaarka = 100 Mbps, huruud = 10 Mbps

  • Qaboojinta is-dhexgalka ee aan lahayn hawo: Ma jiraan qaybo dhaqdhaqaaq ah, taas oo baabi'ineysa meelaha qalalaasaha farsamada iyo yareynta baahiyaha dayactirka ee boodhka leh, jawiga gariirka sare leh.

  • DIN rail ama lakab lagu rakibayo: Waxay taageertaa labada habab ee lagu dhejiyo oo leh xidhmooyinka xirmooyinka la aqoonsan yahay ee ikhtiyaarka ah; jihada dabacsan (toosan ama siman) ee loogu talagalay qalabka xakamaynta dadka badan.

  • Isticmaalka awoodda yar (5 W oo caadi ah): Kuwa xadgudubka iyo kuwa ka soo baxa waxa ka yimid qabowga gacan iyo kuwa ka soo baxa, oo ka caawinaa in la sameeyo koox badan oo kuwa ku jira qabowga heerka.

  • Ka weydiistaa 4 miliyoon saacadood MTBF @ 35 °C: Xusno dhinaca aad u leh ayaa si guul dar ah u caawinaa amarka dheer ee seynta, oo ka caawinaa in la sameeyo fadhiis badan ee dhaqanka.

  • HP‑MDIX auto‑sensing: Wuxuu isku daynayaa iyo isku xasirayaa kableyada straight‑through ama crossover ee dhammaan portada RJ45, oo ka saarayaa in la doonayo kableyada la xiriira.

Funkushenaha

  • Wuxuu dhaqameynayaa iyo buufareynayaa warbixin I/O ee dhaqameyn, xusuusinta controllerka, iyo warbixin HMI ee dhammaan controllerkii Mark VIe/VIeS, I/O packs, iyo staashinka HMI ee ku jira IONet.

  • Wuxuu isku xasirayaa 10/100 Mbps iyo modhka full/half‑duplex ee dhammaan portada copper ee ku jira, oo ku xasirayaa xusnooyinka ku jira kuwa ka soo baxa ee meelaha, oo ka saarayaa in la sameeyo xasirka manual ee portada.

  • Wuxuu sameeyaa switching ee full‑duplex ee aan la jirin collosion ee dhammaan 8 portada, oo ka saarayaa collosionka packet, iyo ka caawinaa in la helo latency ee la xiriira wakhtiga, oo ka caawinaa xusnooyinka control ee turbine ee la xiriira wakhtiga.

  • Waxay ku dhaartaa xiriirka data ee la aqbal karo (deterministic) ka dib marka laga helo shabakadda oo ku jira copper-ka kaliya, la isu daynin doonayo qorshaha caawinayaasha iyo qorshaha loogu qorsho gacan (protocol translation devices).

  • Waxay sidaanayaan wararka xaqiis ah ee xafiiska iyo xiriirka shabakada (network health) kala duwan ee xafiiska kala duwan (bi-colour per-port LEDs), taas oo waxay kordhinaysaa in la tuurado qaybta (on-site) mar dambe oo ka badan, la isu daynin doonayo software-ka tuuradaha caawinayaasha.

  • Waxay ku qorsho gacan (electrically isolates) xafiiskooda la xidhiidha (redundant power inputs) kuwa laga helo diode-OR’d architecture; haddii xafiiska ugu horreeyey (primary power rail) ka dhacdo, xafiiska labaad (secondary rail) wuxuu ku xidhiidha xafiiska (load) oo aan la jiro dhibaato (interruption) ee shakhsiga (switch operation).

  • Waxay sidaanayaan tayada (passive store-and-forward) ee qoraalka (packet processing) kuwa laga helo control-ka (pause frame flow control), waxay ku xidhiidhaan (buffering) xafiiskooda soo noqda (incoming traffic) iyo ku xidhiidhaan dhibaato (data loss) marka xafiiskooda ka soo noqda (downstream ports) ay la jiro xoolo (congested).

  • Waxay shaqeynaysaa mar dambe (continuously) ka dib marka laga helo xoolooyinka (environments) ee ka badan (extreme) (–40 °C ilaa +70 °C) kuwa laga helo fanless convection cooling, waxay ku xidhiidhaan (eliminating) qaybaha la jiro (moving parts) oo ay la jiro dhibaato (fail) ka dib marka laga helo xoolooyinka (dusty) ama xoolooyinka la jiro dhibaato (vibration-prone) ee turbinada (turbine) ee xafiiskooda (control cabinets).

  • Uga wada qabaa laba taliyaha 24/28 V DC (qoraal 18–36 V DC) ka mid ah la xiriirka Mark VIe ee dhaqanka iyo qorshaha ku saabsan (JPDS, JPDG, JPDH) ama taliyaha dhaqanka ka baxa jirka.

  • Wax u dhajiso qaybaha I/O iyo qaybaha xiriirka kuwa la isticmaalo IEEE 1588 Precision Time Protocol (PTP), oo ku dhaqanaya in la jiro ≤ 1 µs ka wada hadal ee saacadda si loo sameeyo daqiiqada saacadda iyo daqiiqada habka hadalka.

Dhibaatooyinka soo galay

Su’aal 1: Ma aha IS420ESWAH3A?
Jawaab 1: IS420ESWAH3A waa qaybaha Ethernet ee industriyada ee aan la isticmaalo xariirka copper-ka, oo wax ugu dhowaaday in ay ugu yar tahay qaybaha xiriirka ee GE Mark VIe/VIeS IONet ee ku jira qaybaha xiriirka turbinada, oo ku xidhaya qaybaha xiriirka, qaybaha I/O, iyo HMIs.

Su’aal 2: Kuwan kuu jira qaybaha IS420ESWAH3A iyo meelaha?
A2: Waa IS420ESWAH3A waa 8 × 10/100Base-TX copper RJ45 ports. Maya qaybaha fibre — tani waa mudhaalad ka mid ah copper-ka, oo lagu dhisay qaybaha xiriirka ee ku jira.

Su’aal 3: Ma aha isku daynka saacadaha ee IS420ESWAH3A?
Jawaab 3: IS420ESWAH3A wada xadgudubaa ka dari 40 °C ilaa +70 °C waxaana la isticmaala convection cooling oo aan fan ahayn iyo G3 conformal coating, taas oo wax u qabsoona khatarka dhexeeya turbinada iyo cabinetada industriya ee aan la tiiyin.

Su’aal 4: Ma IS420ESWAH3A wuxuu ku saabsanaya xariirka isku dhafan ee jawaabka?
A4: Haa. Qorshu IS420ESWAH3A waxa uu leeyahay laba taliyaha 24/28 V DC (TB1 iyo TB2) oo aan la xiriirin, oo waxa uu ku xidhnaa diode‑OR. Haddii taliyaha ka mid ah ay dhacdo, isku daynta waxa uu ku dhaqmayaa taliyaha kale ee si wanaagsan ugu dhaqmayaa.

Su’aal 5: Ma IS420ESWAH3A wuxuu ku saabsanaya waddooyinka khatarka?
A5: Haa, IS420ESWAH3A wuxuu ku saabsanaya UL Class I, Division 2, Groups A-D iyo ATEX Zone 2 ee waddooyinka khatarka (classified). Waxaana leeyahay IEC 61508 SIL 2 ee ku saabsanaya waddooyinka siyaasadeed ee aad ugu yar tahay.