Magaca Alaabta: Multi-Client Enhanced Communications Module
Magaca Brand: Prosoft
Lambarka Modelka: MVI56E-MNETCR
Dalka kaleyska: Dhalinyarada Amerikanka
Damaanad: boqortooyada 12 Bulsho
Whatsapp: +86 18159889985
Iimaylka: [email protected]
Magaca Brand: |
Prosoft |
Lambarka Modelka: |
MVI56E-MNETCR |
Dalka kaleyska: |
Dhalinyarada Amerikanka |
Furaha Talaalada: |
Cusub oo ah orijinaalka, oo ku dhaqmayn khasabta ah |
Wakhtiga aad ugu yaraysid: |
Wakhtiga soo guurinta marka la jirto magaalo |
Shurtida Casirada: |
T/T |
Waxaa ProSoft Technology MVI56E-MNETCR waa mooluudka la xiriira koorinta Modbus TCP/IP ee ka mid ah qaybaha Rockwell Automation ControlLogix. The MVI56E-MNETCR waa la sameeyay si gaar ah kuwa lagu dhisayaa qaybaha ka duwan ee chassis, oo isticmaalaya waraqada xogta I/O la yaryahay ee ka dhigan tahay kuwa la isticmaalo ControlNet . Wuxuu tixgelin karaa ilaa 30 kaalayda Modbus TCP/IP la joogo mar aad leh, MVI56E-MNETCR wuxuu xidhiidha PACs-ka ControlLogix si guul dar ah, oo isticmaalaya Add-On Instruction ama logic ladder la isticmaalo, MVI56E-MNETCR wuxuu leeyahay server-ka web ee ka jira, Seerviis-ka ProSoft Discovery, iyo tekinoolojiyada CIPconnect si loo isticmaalo in la sameeyo isku daynta iyo fikradaha fikradaha .
Xidhiidhka PACs-ka ControlLogix ilaa qaybaha ka duwan ee Modbus TCP/IP, sida PACs-ka Schneider Electric Modicon
Ka saaritaan xogta weyn oo ka duwan ee qaybaha ka duwan ee Modbus TCP/IP ee qofka gudaha iyo qaybaha
Waxyaabaha oo leeyahay xidhiidhka guul dar ah ee ControlLogix chassis-ka ka duwan ee ControlNet ama EtherNet/IP
Magaaladaha iyo qaybaha industriyada oo leeyahay waxyaabaha ControlLogix in la xidhiidho iyo la heesayo qaybaha ka duwan oo mar aad leh
Wuxuu tixgelin karaa ilaa 30 kaalayda Modbus TCP/IP : Si guul dar ah ugu xallin karaa qaybaha ka duwan ee seervar-ka, oo kasta oo kaalay wuxuu leeyahay liiska amarka la isticmaalo
La xusaynayay in lagu isticmaalo Qaabka Dhexe ee Kaalaa : Khaasimaha dhinaca kaalaa ay u yar yahay waxay muujinayaan in ay ku saabsan yihiin RSNetworx, waxayna kordhinayaan awoodaha ugu yar ee qoraalka I/O kale
La xusaynayay in lagu isticmaalo Farqiga La Darbada (AOI) : Wuxuu uga gacan karaa sida caadi ah in lagu dhisayo, waxayna uga gacan karaa in lagu dhisayo kuwa RSLogix 5000
La xusaynayay in lagu isticmaalo Web Serverka : Wuxuu uga gacan karaa in lagu fikro qoraalka, xaaladda, iyo isku daynta firmware-ka kuwa Ethernet
Qoraalka Xaaladda : Kardanka Compact Flash ee jiritaanka waa la isticmaali karaa in lagu wareegiyo xaaladda guud ee qoraalka si loo sameeyo daryeelka natiijadeed
Qoraalka LED ee La Darbada : Wuxuu muujinayaan xaaladda iyo wararka xadgudubka ee Ingiriis
Waxa uu la xiriiraan karaa kuwa soo socda : Wadaagaa loogic-ka laddar iyo failyaha u qorista iyadoo la isticmaalo moduleyada MVI56-MNETCR ee ka hor inta badan si loo isticmaalo si fudud ah
Waxay shaqeyn doonaan sida Modbus TCP/IP Client (Master) oo ku xidhanaya platformka ControlLogix, iyo ku xidhanaya in ay isku xidhaan karaan qoraal ka badan oo ku dhex jira server
Waxay ugu yaraysaan 5000 register kaasoo ku saabsan data user ee ku jira database-ka aawowga iyo processor-ka ControlLogix ku xidhanaya backplane
Waxay tixgelinayaan Koodiyada Faahfaahinta Modbus 1, 2, 3, 4, 5, 6, 15, iyo 16 si loo xusuuso data guurka ah
Waxay tixgelinayaan kuwa soo socda 30 client connection, midigooda waxay leedahay liiska amarada 16
Waxay xusin doonaan nooca data ka badan, taasoo leh bit-level iyo register-level data, iyo waxay tixgelinayaan qiimaha floating-point
Waxay samayn doonaan u qorista iyo faahfaahinta kuwa soo socda Ethernet port-ka module-ka ku xidhanaya ProSoft Configuration Builder
Su’aal 1: Maxay MVI56E-MNETCR ku sameyn doonaan?
A1: Waxaa MVI56E-MNETCR waa module-ka communication ee Modbus TCP/IP multi-client oo ku xidhanaya Rockwell Automation ControlLogix PACs si ay ugu xidhaan karaan qoraal ka badan oo ku dhex jira Modbus TCP/IP server devices.
Su’aal 2: Waa maxay faaiidada muhiimka ah ee MVI56E-MNETCR kuwa ka sarreeya MNETC ee caadiga ah?
A2: Waxaa MVI56E-MNETCR wuxuu u isticmaalaan khaas ah oo ka saabsan isku daynta remote chassis, sidaas darteed wuxuu isticmaalaan qaybka I/O ee la xidhiidhaa, taas oo ku saabsan yahay in lagu isticmaalo ControlNet.
Su’aal 3: Kuwan MVI56E-MNETCR waa ku daran kuwan Modbus TCP/IP ee ka mid ah?
A3: Waxaa MVI56E-MNETCR wuxuu ku daran karaa kuwan Modbus TCP/IP ee 30 oo la joogo .
Su’aal 4: Sidaad u sameysaa xaqiijinta MVI56E-MNETCR?
A4: Waxaa MVI56E-MNETCR wuxuu xaqiijin karaa isticmaalaya ProSoft Configuration Builder (PCB) software, oo waxaa laga heli karaa iyadoo isticmaalaya portka Ethernet ee moduulka .
Su’aal 5: Software-ka ku saabsan kuwan MVI56E-MNETCR iyo RSLogix 5000 waa?
A5: Waxaa MVI56E-MNETCR wuxuu ku jiraa Add-On Instruction (AOI) ama tusaale oo loogic ladder oo ku saabsan yahay in lagu dhisayo RSLogix 5000 oo ka badan 16 ama ay ku jirto.
Ku xiriir hadda : [email protected]