Product Name:Power Status Module
Brand Name: HONEYWELL
Model Number:10216/2/1
Country of Origin:USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
HONEYWELL |
Model Number: |
10216/2/1 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Manufacturer |
Honeywell |
|
Catalog Number |
10216/2/1 (12400) |
|
Product Type |
Fail-Safe Loop-Monitored Digital Output Module |
|
Output Channels |
4 |
|
Output Voltage |
24 Vdc |
|
Maximum Channel Current |
1 A |
|
Maximum Module Load |
3.6 A |
|
Maximum Load Inductance |
0.5 H |
|
Maximum Load Capacitance |
1 µF |
|
Voltage Drop at 1 A |
< 1.3 V |
|
Off-State Leakage |
< 0.1 mA |
|
Overload Detection Threshold |
> 10 Ω |
|
Cold Resistance (Lamp) |
> 20 Ω |
|
5 Vdc Power Requirement |
15 mA |
|
24 Vdc Internal Power |
50 mA |
|
24 Vdc External Power |
15 mA (no load) |
|
WDG Input Current |
4 mA |
|
Space Requirement |
4 TE × 3 HE (4 HP × 3U) |
|
Module Code |
Holes A13, C9 |
|
Rack Code |
Large pins A13, C9 |
|
Approvals |
CE, TÜV, UL |
|
Software Version |
≥ 3.00 |
|
System Compatibility |
Honeywell FSC (Fail Safe Controller) |
The Honeywell 10216/2/1 is a fail-safe loop-monitored digital output module engineered for the Honeywell FSC system. This 10216/2/1 module provides four 24 Vdc output channels, each rated at 1 A, to drive resistive or inductive loads up to 24 W per channel. The Honeywell 10216/2/1 incorporates comprehensive diagnostics including lead breakage detection and short-circuit monitoring. Certified by CE, TÜV, and UL, the 10216/2/1 is a trusted solution for safety-critical applications.
Comprehensive Self-Testing – Outputs are fully tested for de-energization capability, secondary de-energization, crosstalk, suppression diode function, lead breakage, and short circuits.
Secondary De-Energization – Independent watchdog and processor-controlled shutdown ensures fail-safe operation regardless of application function status.
Loop-Monitoring with Range Setting – Lead breakage and short-circuit detection with programmable current sense levels via 10216/A/. range-setting modules.
TÜV, CE, and UL Certified – Globally recognized safety approvals for use in Emergency Shutdown (ESD) and Fire & Gas (F&G) systems.
Compact 4 TE Form Factor – Space-efficient design for high-density rack installations.
4 fail-safe loop-monitored 24 Vdc output channels
1 A continuous current per channel; 3.6 A total module capacity
Supports resistive and inductive loads with integrated suppression diodes
Short-circuit proof solid-state sourcing outputs
Lead breakage and short-circuit detection with programmable sense levels
Secondary de-energization via watchdog and processor
Comprehensive self-testing: de-energization, crosstalk, diode function
10216/A/. range-setting modules for current sense level programming
CE, TÜV, and UL approved
Software version ≥ 3.00 required
Fail-Safe Output Control – Drives up to four independent 24 Vdc loads (resistive or inductive) with 1 A per channel, providing reliable de-energization upon demand or fault detection.
Continuous Loop Monitoring – Each output channel is continuously monitored for lead breakage and short circuits. The current sense level is programmed using 10216/A/. range-setting modules to match the load characteristics.
Comprehensive Self-Testing – The module automatically tests each output for de-energization capability, secondary de-energization via watchdog/processor, crosstalk between channels, suppression diode integrity, lead breakage in external wiring, and short circuits.
Secondary De-Energization – Independent of the application logic, the watchdog and/or processor can force outputs to a de-energized state, ensuring fail-safe behaviour even if the application function fails.
System Integration – Requires an I/O backplane and a 10216/A/. range-setting module per channel (or 10216/A/1 for spare channels). Both internal (d8/z8) and external (d6/z6, d30/z30) power supplies must be connected to prevent fault detection during self-test.
Q1: What is the Honeywell 10216/2/1 used for?
The 10216/2/1 is a fail-safe loop-monitored digital output module used in Honeywell FSC systems to drive 24 Vdc loads in safety-critical applications such as Emergency Shutdown (ESD) and Fire & Gas (F&G) systems.
Q2: How many output channels does the 10216/2/1 have?
The 10216/2/1 provides four independent 24 Vdc output channels, each rated at 1 A continuous current.
Q3: What type of loads can the 10216/2/1 drive?
The 10216/2/1 can drive both resistive and inductive loads up to 24 W per channel. For inductive loads, integrated suppression diodes are provided on each output.
Q4: What range-setting modules are compatible with the 10216/2/1?
The 10216/2/1 uses 10216/A/. range-setting modules to program the current sense level: 10216/A/1 for spare channels, 10216/A/2 for 0.4–1.1 W loads, 10216/A/3 for 1.2–4.7 W loads, and 10216/A/4 for loads ≥4.8 W.
Q5: What approvals does the 10216/2/1 hold?
The 10216/2/1 is certified by CE, TÜV, and UL for use in mission-critical industrial safety applications.
Inquiry Now :[email protected]