Product Name:Power Status Module

Brand Name: HONEYWELL

Model Number:10216/2/1

Country of Origin:USA

Warranty: 12 Months

Whatsapp:+86 18159889985

Email:[email protected]

Appurtenance:
  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Competitive Advantage
  • Features
  • Functions
  • FAQ
  • Recommended Products

Overview

Brand Name:

HONEYWELL

Model Number:

10216/2/1

Country of Origin:

USA

Packaging Details:

Original new Factory Sealed

Delivery Time:

Delivery time in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter

Specification

Manufacturer

Honeywell

Catalog Number

10216/2/1 (12400)

Product Type

Fail-Safe Loop-Monitored Digital Output Module

Output Channels

4

Output Voltage

24 Vdc

Maximum Channel Current

1 A

Maximum Module Load

3.6 A

Maximum Load Inductance

0.5 H

Maximum Load Capacitance

1 µF

Voltage Drop at 1 A

< 1.3 V

Off-State Leakage

< 0.1 mA

Overload Detection Threshold

> 10 Ω

Cold Resistance (Lamp)

> 20 Ω

5 Vdc Power Requirement

15 mA

24 Vdc Internal Power

50 mA

24 Vdc External Power

15 mA (no load)

WDG Input Current

4 mA

Space Requirement

4 TE × 3 HE (4 HP × 3U)

Module Code

Holes A13, C9

Rack Code

Large pins A13, C9

Approvals

CE, TÜV, UL

Software Version

≥ 3.00

System Compatibility

Honeywell FSC (Fail Safe Controller)

Description

The Honeywell 10216/2/1 is a fail-safe loop-monitored digital output module engineered for the Honeywell FSC system. This 10216/2/1 module provides four 24 Vdc output channels, each rated at 1 A, to drive resistive or inductive loads up to 24 W per channel. The Honeywell 10216/2/1 incorporates comprehensive diagnostics including lead breakage detection and short-circuit monitoring. Certified by CE, TÜV, and UL, the 10216/2/1 is a trusted solution for safety-critical applications.

Competitive Advantage

  • Comprehensive Self-Testing – Outputs are fully tested for de-energization capability, secondary de-energization, crosstalk, suppression diode function, lead breakage, and short circuits.

  • Secondary De-Energization – Independent watchdog and processor-controlled shutdown ensures fail-safe operation regardless of application function status.

  • Loop-Monitoring with Range Setting – Lead breakage and short-circuit detection with programmable current sense levels via 10216/A/. range-setting modules.

  • TÜV, CE, and UL Certified – Globally recognized safety approvals for use in Emergency Shutdown (ESD) and Fire & Gas (F&G) systems.

  • Compact 4 TE Form Factor – Space-efficient design for high-density rack installations.

Features

  • 4 fail-safe loop-monitored 24 Vdc output channels

  • 1 A continuous current per channel; 3.6 A total module capacity

  • Supports resistive and inductive loads with integrated suppression diodes

  • Short-circuit proof solid-state sourcing outputs

  • Lead breakage and short-circuit detection with programmable sense levels

  • Secondary de-energization via watchdog and processor

  • Comprehensive self-testing: de-energization, crosstalk, diode function

  • 10216/A/. range-setting modules for current sense level programming

  • CE, TÜV, and UL approved

  • Software version ≥ 3.00 required

Functions

  • Fail-Safe Output Control – Drives up to four independent 24 Vdc loads (resistive or inductive) with 1 A per channel, providing reliable de-energization upon demand or fault detection.

  • Continuous Loop Monitoring – Each output channel is continuously monitored for lead breakage and short circuits. The current sense level is programmed using 10216/A/. range-setting modules to match the load characteristics.

  • Comprehensive Self-Testing – The module automatically tests each output for de-energization capability, secondary de-energization via watchdog/processor, crosstalk between channels, suppression diode integrity, lead breakage in external wiring, and short circuits.

  • Secondary De-Energization – Independent of the application logic, the watchdog and/or processor can force outputs to a de-energized state, ensuring fail-safe behaviour even if the application function fails.

  • System Integration – Requires an I/O backplane and a 10216/A/. range-setting module per channel (or 10216/A/1 for spare channels). Both internal (d8/z8) and external (d6/z6, d30/z30) power supplies must be connected to prevent fault detection during self-test.

FAQ

Q1: What is the Honeywell 10216/2/1 used for?
The 10216/2/1 is a fail-safe loop-monitored digital output module used in Honeywell FSC systems to drive 24 Vdc loads in safety-critical applications such as Emergency Shutdown (ESD) and Fire & Gas (F&G) systems.

Q2: How many output channels does the 10216/2/1 have?
The 10216/2/1 provides four independent 24 Vdc output channels, each rated at 1 A continuous current.

Q3: What type of loads can the 10216/2/1 drive?
The 10216/2/1 can drive both resistive and inductive loads up to 24 W per channel. For inductive loads, integrated suppression diodes are provided on each output.

Q4: What range-setting modules are compatible with the 10216/2/1?
The 10216/2/1 uses 10216/A/. range-setting modules to program the current sense level: 10216/A/1 for spare channels, 10216/A/2 for 0.4–1.1 W loads, 10216/A/3 for 1.2–4.7 W loads, and 10216/A/4 for loads ≥4.8 W.

Q5: What approvals does the 10216/2/1 hold?
The 10216/2/1 is certified by CE, TÜV, and UL for use in mission-critical industrial safety applications.