Product Name:Profibus Slave Module
Brand Name: GE
Model Number:HE693PBS106
Country of Origin:USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
General Electric |
Model Number: |
HE693PBS106 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Model |
HE693PBS106 |
|
Manufacturer |
Horner APG / GE Fanuc |
|
Product Type |
PROFIBUS DP Slave Module |
|
Network Type |
|
|
Supported Baud Rates |
|
|
Max Nodes Without Repeater |
|
|
Max Nodes With Repeater |
|
|
Connector Type |
|
|
RS-232 Service Port |
|
|
PLC Compatibility |
|
|
Configuration |
|
|
Input/Output Data |
|
|
Power Supply |
|
|
Operating Voltage |
|
|
Operating Temperature |
|
|
Storage Temperature |
|
|
Humidity |
|
|
Dimensions |
3.5x13x13.5cm |
|
Weight |
0.2kg |
|
Isolation |
|
|
Certifications |
|
|
Status LEDs |
OK, RUN, POWER |
The HE693PBS106 is a PROFIBUS DP slave module from Horner APG, engineered to provide GE Fanuc Series 90-30 and CEGELEC Alspa 8000 PLCs with a high-speed serial communication interface to PROFIBUS DP networks. The HE693PBS106 operates exclusively as a PROFIBUS DP slave device, responding to master-initiated requests and synchronizing I/O data mapping in real time. Supporting baud rates up to 12 Mbps, the HE693PBS106 enables seamless data exchange between the PLC and decentralized peripherals such as I/O devices, drives, valves, and measuring transmitters. Configured as a FOREIGN MODULE (ID 3) in the PLC rack, the HE693PBS106 provides up to 16 words of input and 16 words of output data.
PROFIBUS DP Slave Communication – Establishes deterministic, high-speed serial data exchange between the PLC and PROFIBUS master devices
PLC Data Mapping – Transfers up to 16 words of input and 16 words of output data between the PLC and the PROFIBUS network
Module Status Reporting – Provides a dedicated status word indicating baud rate, DP state, online status, and firmware revision
Firmware Upgradability – RS-232 service port enables field firmware updates
Diagnostic Indication – Three onboard LEDs (OK, RUN, POWER) indicate power status, configuration validity, and network communication state
PROFIBUS DP Slave-Only Operation – Dedicated slave interface with no bus access rights; responds only to master-initiated requests
High-Speed Serial Link – Supports baud rates from 9.6 kbps up to 12 Mbps for fast peripheral data transfers
Flexible Network Topology – Supports up to 32 devices per segment without repeaters, or up to 64 devices with repeaters
9-Pin D-sub PROFIBUS Connector – Standardized physical interface for robust bus connection
RS-232 Service Port – Enables firmware upgrades without removing the module from the rack
Wide PLC Compatibility – Works with all versions of GE Fanuc Series 90-30 and CEGELEC Alspa 8000 PLCs
LogicMaster Support – Configurable using GE Fanuc LogicMaster programming software
Industrial-Grade Isolation – Approx. 1500 VAC field-to-logic isolation
Onboard LED Diagnostics – OK, RUN, and POWER LEDs provide real-time status indication
The HE693PBS106 functions as a PROFIBUS DP slave interface within a master-slave communication architecture. Installed in a GE Fanuc Series 90-30 or CEGELEC Alspa 8000 I/O rack slot, the module is configured as a FOREIGN MODULE (ID 3). The PLC programming software (e.g., LogicMaster) defines the slave station address (1–125), the number of input words (1–16), and the number of output words (1–16).
On the PROFIBUS side, the module connects to the network via a 9-pin D-sub connector. It listens for master-initiated requests and responds accordingly, transferring data between the PROFIBUS network and the PLC‘s memory map. The module does not have bus access rights and cannot initiate communication—it only acknowledges received messages or transmits data when requested by the master. Baud rates from 9.6 kbps to 12 Mbps are automatically detected and supported.
A dedicated status word provides real-time information including the current baud rate, DP state (Wait PRM, Wait CFG, Data Exchange, or Error), online/offline status, and firmware revision. Three onboard LEDs (OK, RUN, POWER) indicate the module’s operational state, from power-up through configuration validation to active data exchange. The RS-232 service port allows for firmware upgrades without removing the module from the rack.
Q1: What PLCs are compatible with the HE693PBS106?
A1: The HE693PBS106 is compatible with all versions of GE Fanuc Series 90-30 PLCs and CEGELEC Alspa 8000 PLCs.
Q2: What is the maximum baud rate supported by the HE693PBS106?
A2: The HE693PBS106 supports baud rates up to 12 Mbps (12 MBd), with a range from 9.6 kbps to 12 Mbps.
Q3: How many devices can be connected on a PROFIBUS DP network with the HE693PBS106?
A3: Up to 32 devices (masters or slaves) can be connected in one segment without repeaters. With repeaters, up to 64 devices can be connected.
Q4: How is the HE693PBS106 configured in the PLC?
A4: The HE693PBS106 is configured as a FOREIGN MODULE (ID 3) in the PLC rack. The configuration fields include the slave station address (1–125), the number of input words (1–16), and the number of output words (1–16).
Q5: Does the HE693PBS106 support PROFIBUS FMS or PA protocols?
A5: No. The HE693PBS106 operates as a PROFIBUS DP module only and does not support other PROFIBUS types such as FMS or PA.