ge fanuc series 90 30 plc profibus slave module he693pbs106 original new-0

GE 90-30 Series PLC

Home >  Products >  GE >  GE 90-30 Series PLC

GE Fanuc Series 90-30 PLC Profibus Slave Module HE693PBS106 Original new

Product Name:Profibus Slave Module 

Brand Name: GE

Model Number:HE693PBS106

Country of Origin:USA

Warranty: 12 Months

Whatsapp:+86 18159889985

Email:[email protected]

Appurtenance:
  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Functions
  • Features
  • Theory of Operation
  • FAQ
  • Recommended Products

Overview

Brand Name:

General Electric

Model Number:

HE693PBS106

Country of Origin:

USA

Packaging Details:

Original new Factory Sealed

Delivery Time:

Delivery time in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter

Specification

Model

HE693PBS106

Manufacturer

Horner APG / GE Fanuc

Product Type

PROFIBUS DP Slave Module

Network Type

PROFIBUS DP (Slave only)

Supported Baud Rates

9.6 kbps to 12 Mbps (12 MBd max)

Max Nodes Without Repeater

32 devices

Max Nodes With Repeater

64 devices

Connector Type

9-pin D-sub PROFIBUS DP port

RS-232 Service Port

9-pin D-sub (firmware upgrades)

PLC Compatibility

GE Fanuc Series 90-30, CEGELEC Alspa 8000

Configuration

FOREIGN MODULE (ID 3)

Input/Output Data

1–16 words input, 1–16 words output (configurable)

Power Supply

5 VDC backplane rail

Operating Voltage

24 VDC

Operating Temperature

0°C to +40°C (32°F to 104°F) without derating

Storage Temperature

–25°C to +60°C

Humidity

5% to 95% non-condensing

Dimensions

3.5x13x13.5cm

Weight

0.2kg

Isolation

Field-to-logic approx. 1500 VAC

Certifications

CE, UL, ATEX

Status LEDs

OK, RUN, POWER

Description

The HE693PBS106 is a PROFIBUS DP slave module from Horner APG, engineered to provide GE Fanuc Series 90-30 and CEGELEC Alspa 8000 PLCs with a high-speed serial communication interface to PROFIBUS DP networks. The HE693PBS106 operates exclusively as a PROFIBUS DP slave device, responding to master-initiated requests and synchronizing I/O data mapping in real time. Supporting baud rates up to 12 Mbps, the HE693PBS106 enables seamless data exchange between the PLC and decentralized peripherals such as I/O devices, drives, valves, and measuring transmitters. Configured as a FOREIGN MODULE (ID 3) in the PLC rack, the HE693PBS106 provides up to 16 words of input and 16 words of output data.

Functions

  • PROFIBUS DP Slave Communication – Establishes deterministic, high-speed serial data exchange between the PLC and PROFIBUS master devices

  • PLC Data Mapping – Transfers up to 16 words of input and 16 words of output data between the PLC and the PROFIBUS network

  • Module Status Reporting – Provides a dedicated status word indicating baud rate, DP state, online status, and firmware revision

  • Firmware Upgradability – RS-232 service port enables field firmware updates

  • Diagnostic Indication – Three onboard LEDs (OK, RUN, POWER) indicate power status, configuration validity, and network communication state

Features

  • PROFIBUS DP Slave-Only Operation – Dedicated slave interface with no bus access rights; responds only to master-initiated requests

  • High-Speed Serial Link – Supports baud rates from 9.6 kbps up to 12 Mbps for fast peripheral data transfers

  • Flexible Network Topology – Supports up to 32 devices per segment without repeaters, or up to 64 devices with repeaters

  • 9-Pin D-sub PROFIBUS Connector – Standardized physical interface for robust bus connection

  • RS-232 Service Port – Enables firmware upgrades without removing the module from the rack

  • Wide PLC Compatibility – Works with all versions of GE Fanuc Series 90-30 and CEGELEC Alspa 8000 PLCs

  • LogicMaster Support – Configurable using GE Fanuc LogicMaster programming software

  • Industrial-Grade Isolation – Approx. 1500 VAC field-to-logic isolation

  • Onboard LED Diagnostics – OK, RUN, and POWER LEDs provide real-time status indication

Theory of Operation

The HE693PBS106 functions as a PROFIBUS DP slave interface within a master-slave communication architecture. Installed in a GE Fanuc Series 90-30 or CEGELEC Alspa 8000 I/O rack slot, the module is configured as a FOREIGN MODULE (ID 3). The PLC programming software (e.g., LogicMaster) defines the slave station address (1–125), the number of input words (1–16), and the number of output words (1–16).

On the PROFIBUS side, the module connects to the network via a 9-pin D-sub connector. It listens for master-initiated requests and responds accordingly, transferring data between the PROFIBUS network and the PLC‘s memory map. The module does not have bus access rights and cannot initiate communication—it only acknowledges received messages or transmits data when requested by the master. Baud rates from 9.6 kbps to 12 Mbps are automatically detected and supported.

A dedicated status word provides real-time information including the current baud rate, DP state (Wait PRM, Wait CFG, Data Exchange, or Error), online/offline status, and firmware revision. Three onboard LEDs (OK, RUN, POWER) indicate the module’s operational state, from power-up through configuration validation to active data exchange. The RS-232 service port allows for firmware upgrades without removing the module from the rack.

FAQ

Q1: What PLCs are compatible with the HE693PBS106?

A1: The HE693PBS106 is compatible with all versions of GE Fanuc Series 90-30 PLCs and CEGELEC Alspa 8000 PLCs.

Q2: What is the maximum baud rate supported by the HE693PBS106?

A2: The HE693PBS106 supports baud rates up to 12 Mbps (12 MBd), with a range from 9.6 kbps to 12 Mbps.

Q3: How many devices can be connected on a PROFIBUS DP network with the HE693PBS106?

A3: Up to 32 devices (masters or slaves) can be connected in one segment without repeaters. With repeaters, up to 64 devices can be connected.

Q4: How is the HE693PBS106 configured in the PLC?

A4: The HE693PBS106 is configured as a FOREIGN MODULE (ID 3) in the PLC rack. The configuration fields include the slave station address (1–125), the number of input words (1–16), and the number of output words (1–16).

Q5: Does the HE693PBS106 support PROFIBUS FMS or PA protocols?

A5: No. The HE693PBS106 operates as a PROFIBUS DP module only and does not support other PROFIBUS types such as FMS or PA.