Nomen producti: electronically fused output module
Nomen marcae: Allen Bradley
Numerus exemplaris: 1756-OB16E
Terra Originis: USA
Warranty: 12 menses
Whatsapp:+86 18159889985
Epistula electronica: [email protected]
Nomen marcae: |
Allen Bradley |
Numerus exemplaris: |
1756-OB16E |
Terra Originis: |
USA |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
Tempus expeditionis, si in deposito |
Conditiones solutionis: |
T/T |
|
Praepositus Venalium: |
Stella |
|
Mitte epistulam electronicam: |
|
|
Contactus per Whatsapp: |
|
Parameter |
Specificatio |
|
Numerus Catalogi |
1756-OB16E |
|
Fabricator |
Rockwell Automation / Allen-Bradley |
|
Exitus |
16 (electronically fused, 8 points per group) |
|
Categoria tensionis |
12/24V DC sourcing |
|
Operans voltage range |
10…31.2V DC |
|
Output Delay Time (Off→On) |
70 µs nominal / 1 ms maximum |
|
Output Delay Time (On→Off) |
360 µs nominal / 1 ms maximum |
|
Current Draw @ 5.1V |
250 mA |
|
Current Draw @ 24V |
2 mA |
|
Potentia totalis plani posterioris |
1.32 W |
|
Dissipatio Energiae (maxime) |
4.1 W @ 60°C |
|
Dissipatio Thermica |
13.98 BTU/hr |
|
Off-state Leakage (max.) |
1 mA per punctum |
|
Cadere Voltatis in Statu On (max.) |
400 mV DC @ 1 A |
|
Currentis per punctum (max.) |
1 A ad 60°C |
|
Currentis per modulum (max.) |
8 A ad 60°C |
|
Currentis impetuosus (typicus) |
2 A pro 10 ms per punctum, repetibilis omni 2 s ad 0°C |
|
Currentus oneris minimus |
3 mA per punctum |
|
Status in modo defectus/programmationis |
Tenet ultimum statum, On vel Off (praedefinitus: Off) |
|
Outputus programmati |
Synchronizatio ≤16.7 s referens ad Tempus Systematis Coordinati |
The 1756-OB16E est modulus electronicus 16-punctus DC output ex familia ControlLogix Allen-Bradley, ingeniosus ad onerum 12/24V DC fideliter subministrandum in automatione industriali exigenti. The 1756-OB16E praebet protectionem electronicam contra curtum circuitum et contra onus nimium quae in millisecondis reagit, eliminans necessitatem fusibilium discretorum dum tempus inactivitatis minuitur. Cum singulae 16 egressus capaces sint currentis continuus 1 A (8 A totalis modulus), the 1756-OB16E subsidit controlum altam densitatem solenoidum, indicatorum, et motorum initiandorum. 1756-OB16E praebet comportamentum programmabile in statu defectus, feedback diagnosticum completum, et certificationes agenticas rigidas pro distributione globali.
Minuta Manutentio & Inactivitas – Fusio electronica eliminat substitutionem fusibilium physicorum; moduli automatico resuscitantur post eliminationem defectus, minimizando interruptiones productionis.
Diagnostica exoptata – LED individualis E‑Fuse indicant canales affictos, accelerando investigationem et minuendo tempus medium ad reparationem.
Responsio Flexibilis ad Defectus – Status programmabiles per punctum (In, Ex, aut Tenere Ultimum) in modis defectus et programmandi permittunt strategias personalis de securitate et continuitate processus.
Footprint Altae Densitatis – 16 output in unico slot diminuunt necessitates spatii chassidis, liberantes slots pro additis modulis I/O aut communicationis.
Nulla Degradatio Programmanda Output – Commutatio solidi status praebet performancem constantem sine attritione contactuum, assurans fiduciam longi temporis in applicationibus alti cycli.
Compliance Globalis – Certificati UL, CSA, CE, ATEX, FM, et KC simplificant conceptionem systematis pro projectis internationalibus.
Protectio electronica contra supercurrentem – Singuli canales output proteguntur independenter contra conditiones circuitus brevis et supercargae per circuitum thermicum interruptorem.
Praestatio commutationis celeris – Delationes sub‑millisecondorum ad activationem/deactivationem supportant applicationes controlis alti velocitatis.
Wide Operating Voltage Range – Accipit 10…31,2 V DC, accommodans variationes in alimentationibus electricis campi et cadentias in cabletis.
Diagnostics E‑Fuse LEDs – Indicatores canalium singulorum accenduntur ubi defectus detegitur, permittens isolationem visualem rapidam defectuum.
Defectus Programmabilis/Status Programmaticus – Quisque punctus configurari potest ut statum ultimum retineat, accendatur, aut extinguatur in responsione ad defectum controlleris vel transitiones modi programmatici.
Architectura Communis Grupata – Octo puncta per grupum commune simplificant connexiones et minuunt complexitatem blocorum terminalium.
Supportus Exsultationum Programmatarum – Exsultationes synchronizari possunt ad Tempus Systematis Coordinatum pro motibus coordinatis aut applicationibus processualibus.
Capacitas Alta Contra Impulsus – Gestit 2 A inrush pro 10 ms per punctum, idoneus pro oneribus lamparum incandescentium et transitoriis capacitivis.
Bloxus Terminalis Removibilis – Bracchia de connexione seriei 1756‑TBxxx aut 1756‑TBNH simplificant installationem et manutenationem.
Approbatio Classis I Divisio 2 – Certificatus pro locis periculosis quando installatur secundum codices securitatis applicabiles.
The 1756-OB16E designatus est ut operetur fidabiliter in latissimo ambitu ambientium industrialium. Conformis est rigorosis normis EMC, inter quas immunitas ad descensum electrostaticum 6 kV contactu / 8 kV aere, immunitas ad radiationem RF 10 V/m ab 80 MHz usque ad 2,7 GHz, et immunitas ad EFT/B ±4 kV in portubus signali. Modulus sustinet transitoria surge ±1 kV linea‑linea et ±2 kV linea‑terra, necnon surge oscillatorium usque ad 3 kV secundum IEEE C37.90.1. Ambitus temperaturae operationis suus sustinet 0°C usque ad 60°C (32°F usque ad 140°F) ad currentem plene nominatam. The 1756-OB16E habet certificationes globales complures, inter quas UL Listed Industrial Control Equipment (File E65584), CSA Certified Process Control Equipment (File LR4689C) cum approbatione Class I Division 2 Groups A‑D, CE Marking pro Directivis EMC et Low Voltage (EN 61326‑1, EN 61131‑2), certificatio ATEX Ex nA IIC T4 X Gc, approbatio FM pro Class I Division 2, et registratio KC. Haec certificationes adimplent normas pro installatione in America Septentrionali, Europa, Australia, et Corea Meridionali.
Q1: Quae est differentia inter 1756-OB16E et modulum output standardis fusibilis?
A1: Ille 1756-OB16E incorporat electronicam protectionem contra overcurrent, quae reagit intra milliseconds ad conditiones cortocircuitus et overload, deinde automatico reset fit post remotionem defectus. Moduli fusibiles standardes requirunt substitutionem physicam fusibilis post singulum defectum, quod augit tempus inoperationis et impensas manutenctionis.
Q2: Quomodo protectio electronica operatur in 1756-OB16E?
A2: Unus quisque canalis habet circuitum thermicum interrumpentem, qui currentem limitat, cum eius temperaturae limen superatur. Cum supervacuum aut curtus circuitus accidit, canalis se ipsum excludit. Postquam canalis refriegerit infra limen, ipsemet restituitur et operationem normalem resumit—si conditio defectus correcta fuerit.
Q3: Quae est maxima currentis continuatio per singulum egressum et per singulum modulum?
A3: Unusquisque egressus usque ad 1 A continuos sustinet ad 60°C, cum capacitate totali moduli 8 A. Modulus etiam 2 A currentem impulsum sustinet per 10 ms pro singulo puncto (repetibile omni 2 secundis) ut onera initia accommodet.
Q4: Num 1756-OB16E uti potest ut locum 1756-OB16I vel 1756-OB16D in systemate iam existente occupet?
A4: Licet omnes tres sint moduli egressus CC 16-punctorum, formam similem habentes, 1756‑OB16E offert electronic fusing et diagnostics renfortes non disponibles sur les versions non protegees. Verifiez les schemas electriques et la configuration de votre systeme pour assurer la compatibilite, car le comportement en cas de defaut peut varier.
Q5: Que se passe-t-il lorsqu’un canal de sortie presente un defaut sur le 1756-OB16E ?
A5: Le canal concerne s’eteint, la LED E‑Fuse correspondante s’allume, et le module continue de fonctionner normalement sur les canaux non affectes. Apres elimination du defaut (court-circuit ou surcharge), le module reinitialise automatiquement le canal ; aucune reinitialisation manuelle ni cycle d’alimentation n’est requis.
Nunc interrogare: [email protected]