Notam: Bently Nevada
Series: 3300 XL 11 mm
Exemplum: 330703-000-090-50-02-00
Descriptio officialis: 3300 XL 11 mm Probe, M14 x 1.5 Thread, Without Armor
Fons officialis: Baker Hughes Bently Nevada datasheet 146256 Rev. T.
Configuration note: A 5 m probe must be used with the 5 m 3300 XL 11 mm Proximitor Sensor; confirm the complete system before quotation.
The 3300 XL 11 mm system provides non-contacting vibration and displacement measurement with extended linear range. Official applications include axial thrust position, ramp differential expansion, reciprocating-compressor rod position or rod drop, tachometer and zero-speed measurement, and Keyphasor phase reference.
|
Genus probae
|
3300 XL 11 mm standard-mount metric probe, M14 x 1.5 thread, without armor
|
|
Unthreaded length option 000
|
0 mm
|
|
Overall case length option 090
|
90 mm
|
|
Total length option 50
|
5,0 m (16,4 ft)
|
|
Connector option 02
|
Connector ClickLoc coaxialis minutus, cavum normale
|
|
Optionem approbationis 00
|
Approbatio ab agencia non requiritur
|
|
Campus linearis systematis
|
4,0 mm (160 mils), fere 0,5 ad 4,5 mm ab obiecto
|
|
Factor scala systematis
|
3,94 V/mm (100 mV/mil) ±10%
|
|
Interstitium recommendatum
|
2.5 mm (100 milia)
|
|
Responsio frequentialis systematis
|
0 ad 8 kHz, +0/−3 dB typice
|
Proba metrica inarmata utitur custode standardi M14 × 1,5, apice PPS, custode ex accipitro inox AISI 304, et cable triaxiali FEP-isolato 75 ohm. Optio 02 praebet connectorem coaxialem minutum ClickLoc sine protectore connectoris.
|
Probe operation and storage
|
-52°C ad +177°C (-62°F ad +351°F)
|
|
Cautio pro sigillo pressuris
|
Expositio infra -34°C (-30°F) fortasse causat defectum praecocem sigilli pressuris
|
|
Humiditas relativa
|
condensatio 100 %, non submergibilis cum connectores proteguntur
|
|
Approval option
|
00 means agency approval is not required
|
|
Target basis
|
Praestatio systematis publicata utitur targete ex accipitro AISI 4140, diametro ad minus 31 mm
|
Hunc probatorem 5,0 m tantum utere cum sensore Proximitor 3300 XL 11 mm 5 m; ne addas calefactorem extensionis nisi confirmata configuratio systematis id postulat. Verifica engagementem filetum M14 x 1,5 non excedere 21 mm, confirma magnitudinem targetis et spatium inter-communicationis, et constitue interstitium systematis ad 2,5 mm post controles compatibilitatis.
|
Physical stock
|
Confirmare ante quotationem
|
|
Stare: Nou, Folosit sau Refacut
|
Supus verificarii pentru unitatea cotata
|
|
Photographiae productī currentis et tabellae nominālis
|
Praesto Ad Petitionem
|
|
Periodo de garantia
|
Disponibil la cerere si confirmat in oferta
|
|
Tempus expeditionis
|
Confirmare ante quotationem
|
|
Status et ambitus testis
|
Sub verificātiōne; recōrda quae sunt ad manum petī possunt
|
|
Modi Solutionis
|
Disponibil la cerere si specificat pe factura proforma
|
|
Tempus responsionis ad citationem
|
Praesto Ad Petitionem
|
|
Fiducia transactionis
|
Quotatio participe, particularum societatis, factura, verificatio ante expeditionem, et registra expeditionis praebentur, ut res postulat
|
Haecne est vera suppetia?
Confirma antequam quotatio datur pro quantitate petita.
Is the unit new, used or refurbished?
Sub verificatio pro unitate specifica offerta.
Possuntne photographiae producti et tabulae nominis praesentes praebiri?
Disponibilis ad petitionem ante confirmationem ordinis.
Quid est de warranty?
Disponibile su richiesta e confermato nella quotazione scritta.
Quando expedi potest?
Confirma antequam quotatio datur, postquam quantitas et destinatio cognoscuntur.
Num est probatum?
Sub verificatio. Postula ambitum examinis applicabilem et registra quae habentur.
Quae methodi solutionis suffragantur?
Ad petitionem habetur et in factura proforma enumeratur.
Quomodo transactio verificatur?
Postula quotatioem particularem, particularum societatis et bancarum, verificatioem unitatis praesentis, facturam et documenta expeditionis.
|
CM579-PNIO/1SAP170901R0001
|
s4C751104
|
S3290-42
|
PDRYCB000
|
HAMBURG GVAG-2VK1S
|
|
3010-073-0013-2
|
100-260-XX RG6
|
RF-EV1012PI-K4 433-80PLUS
|
XT387E 702750
|
T8123 PoE-30W
|
|
NDCU-11
|
2CDG110182R0011
|
NX-100S
|
SDV531-L33
|
QBE2003-P10
|
|
07E38A13AC
|
S4-34415
|
NS770C 10 kgf/cm² 3 kgf/cm²
|
DC374E 420269 R1
|
STHC-MB
|
|
ir-ex-p-0600
|
YA032N
|
6ES7972-0DA00-0AA0
|
DLHM4-300
|
PXG3.M S55842-Z106-A101
|
|
MB3270I-T
|
sdm-1
|
SKDXX0531
|
2CDG110074R0011 UD/S2.300.2
|
AO810V2 3BSE038415R1 / 3BSE013230R1
|
|
FRS-R-200
|
Rkc4.221t-30
|
PCO5000000AM0
|
XF823A XS824-25
|
ES-HND130-I
|
|
UI-8 / UI810 FT-10
|
MMX-400/MMX-1 300
|
RS232-FO 7XV5652-0BA00/BB
|
NBG-12LX
|
Tb541-eth 1SAP114100R0170
|
|
XS630B1MAL2 3RV2901-1J
|
2938730
|
Eurotherm 2404
|
RIA141X-EA
|
ICP11J0450000
|
|
GE 80-517-3N-XTI 80-632-3N-XT
|
AT/S 4.6.2
|
TBS 50 15855
|
1717-AMP
|
6AG1241-1AH30-2XB0
|