Tempus ducens: In stoce
|
Garantia: unum annum
|
|
Modello completo
|
330901-00-40-10-11-05
|
|
Nota
|
Bently Nevada
|
|
Familia producti
|
systema Transductorum Proximitatis 3300 XL NSV
|
|
Typus Producti
|
Capteur de proximité à montage standard, sans armure
|
|
Fīlum Probae
|
1/4-28 UNF-2A
|
|
Longitudo Non Filetata
|
0.0 in
|
|
Longitudo Totalis Corporis
|
4.0 in
|
|
Longitudo totalis
|
1.0 m (39 in), +30 percent / -0 percent
|
|
Conector et Cālum
|
Miniature coaxial ClickLoc connector with connector protector and FluidLoc cable
|
|
Resistentia directa probae
|
4.2 plus or minus 0.5 ohm for the 1.0 m probe
|
|
Campus Linearis
|
1.5 mm (60 mils), approximately 0.25 to 1.75 mm
|
|
Interstitium recommendatum
|
1.0 mm (40 milia)
|
|
Factor Scalae
|
7.87 V/mm (200 mV/mil), +12.5 percent / -20 percent including interchangeability error
|
|
Linearitas
|
Deviation from best-fit straight line less than plus or minus 0.06 mm
|
|
Frequency Responsio
|
0 to 10 kHz, +0 / -3 dB typical
|
|
Materiali
|
PPS probe tip, AISI 304 stainless-steel case and 75 ohm FEP-insulated coaxial cable
|
|
Temperatura operativa
|
-52 ad +177 gradus C (-62 ad +351 gradus F)
|
|
Temperatura servandae
|
-52 ad +177 gradus C (-62 ad +351 gradus F)
|
|
Radius Flexionis Minimus
|
25,4 mm (1,0 in)
|
|
Maxima textura implicata
|
0.375 in pro casum probae 1/4-28
|
|
Recommended probe-case torque
|
5.1 N·m (45 in·lb)
|
|
Optionem Aprobationis Agentiae
|
05 - Plures approbationes
|
|
Dimensiones
|
Diameter maximum probae 5.26 mm; longitudo non filetata 0.0 in; longitudo casus 4.0 in; longitudo totalis 1.0 m; diameter exterior maximus cavi 2.8 mm; diameter exterior maximus connectoris 7.23 mm
|
|
Pondus
|
Pondus typicum probae circiter 14 ad 150 g; folium technicum non indicat pondus exactum huius configurationis completum
|
|
Fons Officialis
|
Folium technicum Baker Hughes Bently Nevada 147385 Rev. R, paginae 2-7, 11 et 30
|
|
Connector probae
|
Miniature male coaxial ClickLoc connector, gold-plated brass
|
|
Protectio Connnectoris
|
Fluorosilicone connector protector supplied by option 11
|
|
Cavea Probatoria
|
75 ohm FEP-insulated coaxial FluidLoc cable, 1.0 m total probe length
|
|
Compatibilitas Systematis
|
Mechanically and electrically compatible with 3300 NSv and previous 3300 RAM probe and extension-cable systems
|
|
Proximitor input
|
Utere cum sensori 3300 XL NSv Proximitor compatibili et longitudine cavi extensionis approbata
|
|
EVA-L-SHB 7-768-656
|
10E3T3N-2/50
|
MLDH1550P
|
|
EX950A-10
|
F-2224HC,783510-16100
|
AN8102-04
|
|
VX3134V-02-5G1
|
4.4T-10-RSC
|
806A0141800E11500
|
|
PKH-RG2AHL0061
|
VTM05SC24
|
MPAS-Q7594-LN01-T
|
|
FL2S-4J6SD-L3
|
IPM8-A6-FWL-20
|
YF2A14-100UB3XLEAX
|
|
FREJA 300
|
9905-866
|
593D157X9010D2T
|
|
30-VF3230-5D-01
|
H2007B-3
|
JFD-2000A
|
|
031SA400C000020
|
MZC1-2V2PS-KPO
|
EXFO IQS-605 | IQS-605P-HS IQS-5240BP IQS-8130NGE
|
|
G205-16
|
140-MN-0100
|
KGX-24-PP
|
|
8US1261-5FM08
|
870-523/281-581
|
AID16D A03B-0807-C104
|
|
DILM7-10
|
4T-32009X
|
880PL-10mA-A
|
|
M2256305-UNC1
|
GE 353302G3
|
SL1-F
|
|
GE 0173B4772G001
|
DVB-S2 NTC/2280.xF 550-00049-000
|
WMZS2C40
|
|
700-BR310A1
|
A30QS300-4
|
CH13S
|
|
GE CR120B 04022
|
2010105S805 108 641809 + RAE 3130328
|
5711-1M
|
|
16PT FE 328091
|
WD1001FALS-403AA0
|
STD830-H2HS6AS-1-A-ADE-11S-A-10A0-00-0000
|
|
AMTPM-B AMT
|
EVC185 ASTAH040MSS0015H04
|
750-P5-G5-S5-HI-A20-R-E-H
|
|
ID3000
|
WMZH3D16T
|
44B-AAA-GDDA-1KB9
|
|
MOD32BNS
|
13VA3-8
|
RT1694/0-27
|
|
VCZAA3100/U
|
AR2-213 NPT 7-130
|
500-5M-25
|