LEAD TIME: In stock
|
WARRANTY: 1 year
|
|
Complete model
|
330901-00-40-10-11-05
|
|
Brand
|
Bently Nevada
|
|
Product family
|
3300 XL NSv Proximity Transducer System
|
|
Product type
|
Standard-mount proximity probe without armor
|
|
Probe thread
|
1/4-28 UNF-2A
|
|
Unthreaded length
|
0.0 in
|
|
Overall case length
|
4.0 in
|
|
Total length
|
1.0 m (39 in), +30 percent / -0 percent
|
|
Connector and cable
|
Miniature coaxial ClickLoc connector with connector protector and FluidLoc cable
|
|
Probe dc resistance
|
4.2 plus or minus 0.5 ohm for the 1.0 m probe
|
|
Linear range
|
1.5 mm (60 mils), approximately 0.25 to 1.75 mm
|
|
Recommended gap
|
1.0 mm (40 mils)
|
|
Scale factor
|
7.87 V/mm (200 mV/mil), +12.5 percent / -20 percent including interchangeability error
|
|
Linearity
|
Deviation from best-fit straight line less than plus or minus 0.06 mm
|
|
Frequency response
|
0 to 10 kHz, +0 / -3 dB typical
|
|
Materials
|
PPS probe tip, AISI 304 stainless-steel case and 75 ohm FEP-insulated coaxial cable
|
|
Operating temperature
|
-52 to +177 degrees C (-62 to +351 degrees F)
|
|
Storage temperature
|
-52 to +177 degrees C (-62 to +351 degrees F)
|
|
Minimum bend radius
|
25.4 mm (1.0 in)
|
|
Maximum thread engagement
|
0.375 in for the 1/4-28 probe case
|
|
Recommended probe-case torque
|
5.1 N m (45 in lb)
|
|
Agency approval option
|
05 - Multiple Approvals
|
|
Dimensions
|
Probe tip 5.26 mm maximum diameter; 0.0 in unthreaded length; 4.0 in case length; 1.0 m total length; cable 2.8 mm maximum outside diameter; connector 7.23 mm maximum outside diameter
|
|
Weight
|
Typical probe weight approximately 14 to 150 g; the official datasheet does not state the exact assembled weight of this complete configuration
|
|
Official source
|
Baker Hughes Bently Nevada datasheet 147385 Rev. R, pages 2-7, 11 and 30
|
|
Probe connector
|
Miniature male coaxial ClickLoc connector, gold-plated brass
|
|
Connector protection
|
Fluorosilicone connector protector supplied by option 11
|
|
Probe cable
|
75 ohm FEP-insulated coaxial FluidLoc cable, 1.0 m total probe length
|
|
System compatibility
|
Mechanically and electrically compatible with 3300 NSv and previous 3300 RAM probe and extension-cable systems
|
|
Proximitor input
|
Use with the matched 3300 XL NSv Proximitor Sensor and approved extension-cable length
|
|
EVA-L-SHB 7-768-656
|
10E3T3N-2/50
|
MLDH1550P
|
|
EX950A-10
|
F-2224HC,783510-16100
|
AN8102-04
|
|
VX3134V-02-5G1
|
4.4T-10-RSC
|
806A0141800E11500
|
|
PKH-RG2AHL0061
|
VTM05SC24
|
MPAS-Q7594-LN01-T
|
|
FL2S-4J6SD-L3
|
IPM8-A6-FWL-20
|
YF2A14-100UB3XLEAX
|
|
FREJA 300
|
9905-866
|
593D157X9010D2T
|
|
30-VF3230-5D-01
|
H2007B-3
|
JFD-2000A
|
|
031SA400C000020
|
MZC1-2V2PS-KPO
|
EXFO IQS-605 | IQS-605P-HS IQS-5240BP IQS-8130NGE
|
|
G205-16
|
140-MN-0100
|
KGX-24-PP
|
|
8US1261-5FM08
|
870-523/281-581
|
AID16D A03B-0807-C104
|
|
DILM7-10
|
4T-32009X
|
880PL-10mA-A
|
|
M2256305-UNC1
|
GE 353302G3
|
SL1-F
|
|
GE 0173B4772G001
|
DVB-S2 NTC/2280.xF 550-00049-000
|
WMZS2C40
|
|
700-BR310A1
|
A30QS300-4
|
CH13S
|
|
GE CR120B 04022
|
2010105S805 108 641809 + RAE 3130328
|
5711-1M
|
|
16PT FE 328091
|
WD1001FALS-403AA0
|
STD830-H2HS6AS-1-A-ADE-11S-A-10A0-00-0000
|
|
AMTPM-B AMT
|
EVC185 ASTAH040MSS0015H04
|
750-P5-G5-S5-HI-A20-R-E-H
|
|
ID3000
|
WMZH3D16T
|
44B-AAA-GDDA-1KB9
|
|
MOD32BNS
|
13VA3-8
|
RT1694/0-27
|
|
VCZAA3100/U
|
AR2-213 NPT 7-130
|
500-5M-25
|