Sensorium Bently Nevada

Pagina prima>Producta>BENTLY NEVADA>Sensorium Bently Nevada

Bently Nevada 3300 XL 330103-02-08-10-02-CN — Sonde de proximité de 8 mm | Neuf d’origine

BENTLY NEVADA · 3300 XL 8 mm
330103-02-08-10-02-CN
Sonda de proximidad M10 x 1 sin blindaje
Non filetata: 20 mm · Causa: 80 mm · Longitudo: 1,0 m
Connector: Miniature coaxial ClickLoc · Cable: Norma
Tempus ducens: In stoce Garantia: unum annum
Appurtenance:
  • Conspectus
  • Data Technica
  • Inquisitio
  • Applicationes et Functiones
  • Operatio
  • Construction
  • Installatio
  • Quaestiones Frequentes
  • Modellos Recommandatos
  • Producta commendata
OFFICIALIS PRODUCTI PRAEVISSIO
3300 XL 8 mm metric proximity probe
Bently Nevada 330103 est un capteur de proximité standard 3300 XL 8 mm avec filetage M10 x 1 et sans armure. Le code complet de commande précise une longueur non filetée de 20 mm, une longueur totale du boîtier de 80 mm, une longueur totale du capteur de 1,0 m et un connecteur coaxial miniature ClickLoc avec câble standard.
Core selection point: Montage métrique standard M10 x 1 avec un capteur à câble standard de 1,0 m.

Data Technica

DATUM OFFICIALE
Data Technica
Dimensions, masse et valeurs de performance tirées de la fiche technique du système Baker Hughes 3300 XL 8 mm.
Modello completo
330103-02-08-10-02-CN
Familia Probe
3300 XL 8 mm metric probe, without armor
Tactus Montandi
M10 x 1
Dimensiones - apex probae
8.0 mm diameter
Dimensiones - longitudo inpartita
20 mm
Dimensiones - longitudo totalis casei
80 mm
Dimensiones - longitudo totalis probae
1,0 m (3,3 pedes)
Dimensiones - diametrum exterius cavi
3.68 mm maximum
Dimensiones - diametrum exterius connexi
7.24 mm maximum
Pondus
Typical catalog probe weight for the 1.0 m configuration: 323 g (11.4 oz); packed shipping weight is not separately stated
Conector / cale
Connector ClickLoc coaxialis minutus, cavum normale
Campus Linearis
2 mm (80 mils), circiter 0.25 ad 2.3 mm ab obiecto
Factor Scalae
7.87 V/mm (200 mV/mil), ±5% pro systema standardis 1 m ad temperaturas 0 usque ad 45 °C
Frequency Responsio
0 ad 10 kHz, +0/-3 dB
Resistentia nominalis probae
7.59 ±0.50 ohm pro longitudine probae 1.0 m

Inquisitio

Applicationes et Functiones

APPLICATIONES ET VALOR PRODUCI
Applicationes et Functiones
Avantages d’adaptation et de configuration pour l’application du capteur 330103-02-08-10-02-CN.
01
Vibratio radialis
Non-contactum mensuramentum vibrationis axis in systemate transductoris 3300 XL 8 mm recte coniuncto.
02
Positio Axīālis
Mensuramentum positionis relativae axis pro punctis observationis impulsum et displacementis axialis.
03
Interstitium staticum et displacium
La sortie du système varie en fonction de la distance par rapport à la cible conductrice, permettant l’observation de la position statique et du déplacement dynamique.
M10 x 1
Montage standard métrique
330103 identifie un capteur à montage standard M10 x 1 sans armure ; le code sélectionné précise une longueur non filetée de 20 mm et une longueur de boîtier de 80 mm.
ClickLoc
Interfacs definitus cavi
L’option 02 spécifie un connecteur coaxial miniature ClickLoc avec câble standard et une longueur totale du capteur de 1,0 m.
Familia Systematis
Maintenabilité assurée par des composants appariés
Use the correct probe, extension-cable and Proximitor Sensor system length. Similar-looking part numbers should not be substituted without verification.

Operatio

Principium mensurationis
Operatio
How the probe contributes to a complete 3300 XL 8 mm proximity transducer system.
01
Sensio correntis vorticosae
The probe creates a non-contact measurement field at its tip. A conductive target changes the system response as gap distance changes.
02
Exitus proportionalis
The matched Proximitor Sensor converts probe-system behavior into a voltage proportional to target distance.
03
Static and dynamic information
The DC component represents average gap or position, while changing displacement provides vibration information.
04
System matching matters
Probe length plus extension-cable length must match the selected Proximitor Sensor system length; similar-looking components should not be mixed without verification.

Construction

Projeto Físico
Construction
Confirmed materials, interfaces and dimensional features for the selected 330103 configuration.
Apicem probulae
8.0 mm PPS tip
The sensing tip is polyphenylene sulfide. The standard-mount probe uses an 8.0 mm tip diameter.
Probe Case
Stainless steel M10 x 1 body
The case is AISI 303 or 304 stainless steel with M10 x 1 mounting thread.
Cavea Probatoria
75 ohm triaxial cable
The standard cable is FEP-insulated. Maximum outside diameter is 3.68 mm.
Conector
Minutus coaxialis ClickLoc
Connector usat material conductiv aurificat et diametrum exterius maximum 7.24 mm.

Installatio

FIELD CHECKS
Installatio
Adaptatio mechanica, directio cavi et limites ambientales quae ante installationem inspiciendae sunt.
Adaptationem mechanicam
20 mm longitudo non filetata et 80 mm cassa
Verifica foramen montis, filetum M10 x 1, spatium inter cassam et engagementum fileti maximum 15 mm.
Directio Cavi
25.4 mm minimum bend radius
Avoid tight bends and protect the probe-to-extension-cable connection from mechanical strain.
System-length match
1.0 m longitudo probae
Elige caleum extensionis et sensorem Proximitor ut longitudo systematis integri recta sit.
Environment
Intervalum probae normale: -52 ad +177 gradus C
Probula usat sigillum pressionis O-ring Viton. Probulae normales non singillatim ad pressionem examinantur antequam mittantur.

Quaestiones Frequentes

BUYER AND ENGINEER CHECKS
Quaestiones Frequentes
Sex quaestiones practicae ad aequationem exacti modelli et supplicantis sub citatione aestimandam.
Q1
Quomodo emptor verificare potest unitatem propositam esse exactum modello?
Petite photographemata temporis signata probulae integrae, libelli imballagii et tabellae nominis quae ostendant 330103-02-08-10-02-CN. Comparate filetum, dimensiones cassae, longitudinem cavi et connectorem cum schedula technica officiali.
Q2
Quomodo emptor novum stockum originale a stocko usato vel restituto distinguit?
Require a written condition statement, clear close-up photos, packaging evidence and disclosure of any opened, repaired or tested history. A datasheet proves specifications, not the condition of an individual unit.
Q3
How should a qualified industrial automation supplier be screened?
Check the legal company name, registration, business address, traceable bank beneficiary, documented quotation terms and a consistent record of supplying identifiable industrial parts.
Q4
What should an engineer verify before approving this probe?
Confirm M10 x 1 mounting, 20 mm unthreaded length, 80 mm case length, 1.0 m probe length, standard ClickLoc connection and the required total 3300 XL system length.
Q5
What evidence should be requested before payment?
Ask for the exact-model quotation, current unit photos, nameplate image, packing details, test scope if offered, warranty wording, dispatch terms and written return or discrepancy procedure.
Q6
Can a similar 330103 code be accepted as a substitute?
Non automatico. Differentiae in longitudine non filettata, longitudine del casus, longitudine del probe, typo de cable, connector e suffixo de approbatione pote affectare installationem vel compatibilitatem del systema. Approba solum post comparatione linea per linea.

Modellos Recommandatos

REFERENTIAE AD STOCKUM RANDOM
Modellos Recommandatos
Sexaginta modelli ex listis TXT praebitis selecti sunt; entria non sunt filtrata per brandum.
760ATC
50098566
1SDA074186R1
554 15D137510
ADAM-5051D
SDV531-L33/PRP
MF6FTJ0026
C65-EW
CCA634
677304
2814605 MCR-F-UI-DC
ASA5505
02-32281-0001
C1B
6ES7131-1BL01-0XB0
PLM 730
RXSF 1 RK 271 019-AH
PCOUMI2000
47-01180
2400381-001
3WL9111-0BA22-0AA0
RM-PS-024-01F
CPU2-3030D
5141SB
PRO 9105
SI816N SI816N.A001
GJR2240900R0001 XV370A-E 9024/021
UTR-BP 54 TA PN:9371636023
THA100
CN35BN3AB
2TMA020070N0006
PCB-FSC-960-03
DC551 / 1SAP220500R0001
DPS-750XB E98791-011
TSXRKY4EX
SX2 J4290-0001C
6131-74-102-500
1RK221052-AH
S100-02443
MSR138.1DP 440R-M23084
0J-0P4506AA
TST8801
LM-24-M
DT 370
VFC-131
40734-01G 3500/40M
800-001-0000
HE-67P3-0N00P
1756-PA75R/A
RTU32 UCN-26IOA/221B0130.D
GPSMAP3006C 011-01023-00
RM8I
440R-P226AGS-NNR
1KO3
BC7300
407766
323A3347P5
UT-H101
96M-180W-44 PN:50082040
16D45

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000