Modello completo |
3500/42M 140734-02 |
Monitor family |
3500/42M Proximitor Monitor Seismicus |
Capacitas canalium |
Quatuor canales |
Supported input classes |
Proximity, velocity or acceleration transducers |
Locus armarii |
One full-height front slot; matching I/O module uses one rear slot |
I/O matching |
Verify the installed I/O module and transducer type against the existing rack configuration |
|
Modello completo
|
3500/42M 140734-02
|
|
Familia producti
|
Bently nevada 3500 series
|
|
Typus Producti
|
Modulus monitoris sismici Proximitor quattuor canalium
|
|
Canali Ingressus
|
Quattuor
|
|
Transductores accepti
|
Signa transductorum proximitatis, velocitatis aut accelerationis
|
|
Consumptio potentiae
|
7,7 W typice
|
|
Impedantia intrantis I/O normalis
|
10 kiloohm
|
|
Alimentātiō transductorum
|
−24 Vcc
|
|
Exitus Registrorum
|
4 ad 20 mA
|
|
Exitus Tamponati
|
Unus connexio coaxialis per canalem; impedantia extrantis 550 ohm
|
|
Indicatores Anteriores
|
LEDs OK, TX/RX et Bypass
|
|
Dimensiones
|
241.3 x 24.4 x 241.8 mm, tabula principalis monitoris
|
|
Pondus
|
0,91 kg
|
|
Spatium rack
|
Unus interstitium frontale altitudinis plenae; modulus I/O occupat unum interstitium posterius altitudinis plenae
|
|
Temperatura operativa
|
-30 ad +65 °C cum terminatione I/O interna vel externa; 0 ad +65 °C cum I/O barrierae internae
|
|
Temperatura servandae
|
-40 usque ad +85 °C
|
|
Humiditas
|
95% non condensans
|
|
Functio systematis
|
Conditioning of signals and comparison of alarms for protection of machinery
|
|
Vibratio radialis
Processes signals from proximity transducers for monitoring of shaft-relative vibration. |
|
Monitoring of seismic activity
Accepts compatible signals of velocity or acceleration for measurements of casing vibration. |
|
Logica protectionis
Compares configured variables with alarm setpoints and communicates status within the 3500 rack. |
|
Modello completo
|
3500/42M 140734-02
|
|
Monitor family
|
3500/42M Proximitor Monitor Seismicus
|
|
Capacitas canalium
|
Quatuor canales
|
|
Supported input classes
|
Proximity, velocity or acceleration transducers
|
|
Locus armarii
|
One full-height front slot; matching I/O module uses one rear slot
|
|
I/O matching
|
Verify the installed I/O module and transducer type against the existing rack configuration
|
|
Instauratio Substructurae
Install the monitor in one full-height front rack slot, with the matching I/O module in the corresponding rear slot. |
|
Verification of I/O
Confirm transducer type, termination style, and installed I/O module before wiring or exchanging modules. |
|
Collaudo
Configure channel type, scale, alarms, and recorder outputs in the 3500 system before activating protection functions. |
|
Standard I/O temperature
-30 ad +65 °C temperatūra operativa cum I/O internis aut externis terminatis. |
|
Temperatūra I/O barrierae
0 ad +65 °C temperatūra operativa cum I/O barrierae internis. |
|
Conservatio et umiditas
-40 ad +85 °C temperatūra conservandi; 95% umiditas non condensans. |
|
3463-0400-0050
|
1180000316
|
700-BX640A1
|
|
BES516327A0Y
|
ADA-8XR
|
NA-OA02-01
|
|
1614-0878-00
|
FAL34015
|
8320B177
|
|
C.A 6240
|
GE IS200DSPXH1D
|
ABB CI867K01 3BSE043660R1
|
|
HUS723020ALS640
|
3D X130
|
GE CR120B 04022
|
|
I12SA400M000061
|
E3T-FT11
|
140DRC83000C
|
|
ET-1214
|
FS-N12N
|
2ZJEM
|
|
S10-950-A 2L005
|
LAH20EM
|
440P-CDPB12E
|
|
159-NB
|
145412700 BVH-100A
|
LC1D25BD
|
|
XS108BLPAL2
|
PWR-BGA12V50W0WW
|
GC-1CC0
|
|
00321458-01
|
VTM05SC24
|
C-11594
|
|
CS-A180E1-11-25-83-PSL-73W
|
CD3-Z7-1
|
2130 /B213000
|
|
FOD-021-L
|
XTCE012B10AD DILM12-10
|
WMZH1D20
|
|
7600-ES + 2TG3CXL 7600ES
|
M-064-DXPY
|
PN:2155/40-01
|
|
1417P-PSI
|
7VK6111-5AB91-4YP0/EE
|
EVC185 ASTAH040MSS0015H04
|
|
534700 A2DF3
|
WMZH2C25
|
GE 6422494G
|
|
WMZT2C02T
|
NORD FLEXBLOC 60493000
|
STB4S-00 C3FF28115J
|
|
3RT1926-2CG31
|
VXZ2230 N-X43
|
531614-15
|
|
100-C09E*10
|
8564E
|
FR13E
|
|
ABB PM864AK01 3BSE018161R1
|
CR305X146C
|
QbD1200
|