Complete model |
3500/42M 140734-02 |
Monitor family |
3500/42M Proximitor Seismic Monitor |
Channel capacity |
Four channels |
Supported input classes |
Proximity, velocity or acceleration transducers |
Rack position |
One full-height front slot; matching I/O module uses one rear slot |
I/O matching |
Verify the installed I/O module and transducer type against the existing rack configuration |
|
Complete model
|
3500/42M 140734-02
|
|
Product family
|
Bently Nevada 3500 Series
|
|
Product type
|
Four-channel Proximitor Seismic Monitor module
|
|
Input channels
|
Four
|
|
Accepted transducers
|
Proximity, velocity or acceleration transducer signals
|
|
Power consumption
|
7.7 W typical
|
|
Standard I/O input impedance
|
10 kilohm
|
|
Transducer supply
|
-24 Vdc
|
|
Recorder outputs
|
4 to 20 mA
|
|
Buffered outputs
|
One coaxial connector per channel; 550 ohm output impedance
|
|
Front indicators
|
OK, TX/RX and Bypass LEDs
|
|
Dimensions
|
241.3 x 24.4 x 241.8 mm, monitor main board
|
|
Weight
|
0.91 kg
|
|
Rack space
|
One full-height front slot; I/O module occupies one full-height rear slot
|
|
Operating temperature
|
-30 to +65 deg C with internal or external termination I/O; 0 to +65 deg C with internal barrier I/O
|
|
Storage temperature
|
-40 to +85 deg C
|
|
Humidity
|
95% noncondensing
|
|
System function
|
Signal conditioning and alarm comparison for machinery protection
|
|
Radial vibration
Processes proximity transducer signals for shaft-relative vibration monitoring. |
|
Seismic monitoring
Accepts compatible velocity or acceleration signals for casing vibration measurements. |
|
Protection logic
Compares configured variables with alarm setpoints and communicates status within the 3500 rack. |
|
Complete model
|
3500/42M 140734-02
|
|
Monitor family
|
3500/42M Proximitor Seismic Monitor
|
|
Channel capacity
|
Four channels
|
|
Supported input classes
|
Proximity, velocity or acceleration transducers
|
|
Rack position
|
One full-height front slot; matching I/O module uses one rear slot
|
|
I/O matching
|
Verify the installed I/O module and transducer type against the existing rack configuration
|
|
Rack installation
Install the monitor in one full-height front rack slot with the matching I/O module in the corresponding rear slot. |
|
I/O verification
Confirm transducer type, termination style and installed I/O module before wiring or module exchange. |
|
Commissioning
Configure channel type, scale, alarms and recorder outputs in the 3500 system before placing protection functions in service. |
|
Standard I/O temperature
-30 to +65 deg C operating range with internal or external termination I/O. |
|
Barrier I/O temperature
0 to +65 deg C operating range with internal barrier I/O. |
|
Storage and humidity
-40 to +85 deg C storage; 95% noncondensing humidity. |
|
3463-0400-0050
|
1180000316
|
700-BX640A1
|
|
BES516327A0Y
|
ADA-8XR
|
NA-OA02-01
|
|
1614-0878-00
|
FAL34015
|
8320B177
|
|
C.A 6240
|
GE IS200DSPXH1D
|
ABB CI867K01 3BSE043660R1
|
|
HUS723020ALS640
|
3D X130
|
GE CR120B 04022
|
|
I12SA400M000061
|
E3T-FT11
|
140DRC83000C
|
|
ET-1214
|
FS-N12N
|
2ZJEM
|
|
S10-950-A 2L005
|
LAH20EM
|
440P-CDPB12E
|
|
159-NB
|
145412700 BVH-100A
|
LC1D25BD
|
|
XS108BLPAL2
|
PWR-BGA12V50W0WW
|
GC-1CC0
|
|
00321458-01
|
VTM05SC24
|
C-11594
|
|
CS-A180E1-11-25-83-PSL-73W
|
CD3-Z7-1
|
2130 /B213000
|
|
FOD-021-L
|
XTCE012B10AD DILM12-10
|
WMZH1D20
|
|
7600-ES + 2TG3CXL 7600ES
|
M-064-DXPY
|
PN:2155/40-01
|
|
1417P-PSI
|
7VK6111-5AB91-4YP0/EE
|
EVC185 ASTAH040MSS0015H04
|
|
534700 A2DF3
|
WMZH2C25
|
GE 6422494G
|
|
WMZT2C02T
|
NORD FLEXBLOC 60493000
|
STB4S-00 C3FF28115J
|
|
3RT1926-2CG31
|
VXZ2230 N-X43
|
531614-15
|
|
100-C09E*10
|
8564E
|
FR13E
|
|
ABB PM864AK01 3BSE018161R1
|
CR305X146C
|
QbD1200
|