Nomen producti: Dual Channel Measuring Amplifier
Nomen marcae: Emerson Epro
Numerus exemplaris: MMS6410
Terra Originis: USA
Warranty: 12 menses
Whatsapp :+86 18159889985
Electronicum :[email protected]
Nomen marcae: |
Emerson Epro |
Numerus exemplaris: |
MMS6410 |
Terra Originis: |
USA |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
in stirpe |
Conditiones solutionis: |
T/T |
|
Praepositus Venalium: |
Stella |
|
Mitte epistulam electronicam: |
|
|
Contactus per Whatsapp: |
|
Parameter |
Specificatio |
|
Formam |
MMS6410 |
|
Fabricator |
epro GmbH |
|
Familia Productorum |
MMS 6000 Maschinenüberwachungssystem |
|
Numerus canalium |
2 independent differential inputs |
|
Sensor type |
Induktive Verschiebungssensoren (z. B. PR 9350-Serie), Halb-/Vollbrücke, differentielle Transformatoren (LVDT/RVDT) |
|
Frequencia portans |
4,75 kHz |
|
Tensio alimentationis sensoris |
4 Vrms (aequilibriata ad terram) |
|
Onus Permissum Sensoris |
120…600 Ω |
|
Max. voltage input |
3.6 V (protegita contra supra-tensionem) |
|
Intervallo Nominali Tensionis Intrantis |
2.5 Vrms |
|
Input impedimentum |
200 kΩ |
|
Intervallo Frequentiae Mensurae |
0…100 Hz (–3 dB) |
|
Intervallo Mensurae Displacementis |
Dependit ab intervallo transductoris; signa exire possunt inversa |
|
Signa electrica analogica |
2 × 0/4…20 mA (configurabilis, contra cortocircuitum tutus, onus maximum 500 Ω) |
|
Signa tensionis analogica (CC) |
2 × 0…+10 V (contra cortocircuitum tutus, onus ≥10 kΩ, resolutio 8-bit) |
|
Signa tensionis analogica (dinamica) |
2 × 0…12 Vp (contra cortocircuitum tutus, onus ≥100 kΩ, 0 Hz…20 kHz) |
|
Accuratio |
±1% valoris pleni (omnes exitiones) |
|
Resolutio (signa electrica) |
16-bit |
|
Egressus allarum |
4 exitiones optocoupler (2 per canal), Umax=48 V CC, Imax=100 mA |
|
Intervalus adustionis limitis alarmi |
5…100% valoris pleni |
|
Tempus morae |
0…5 s (eligi possunt) |
|
Ingressus directionis |
Modus optocoupleris, inhibere alarmum, multiplicator ascensus (1.000…4.999), logica 24 V |
|
Ingressus Keyphasor |
1 pulsus/revolutio (logica 24 V, duratio pulsus minima 10 µs, excitatus per marginem) |
|
Interfacies Communicationis |
RS 232 (in facie anterius, configuratio localis); RS 485 (usque ad 31 modulos / 62 canales per bus) |
|
Fontem electricitatis |
18…31.2 V DC (ingressus redundantis, decouplati per diodum) |
|
Consumptio potentiae |
Maxime 8 W (maxime 300 mA ad 24 V) |
|
Temperatura operativa |
0 ad +65°C |
|
Temperatura Conservandi/Transportandi |
–30 ad +85°C |
|
Humiditas relativa |
5 ad 95 % (non condensans) |
|
Resistentia vibrationibus |
0.15 mm amplitude (10–55 Hz); 16.6 m/s² (55–150 Hz) |
|
Resistentia ad ictum |
98 m/s² peak, 16 ms duration |
|
Classis tutelae |
IP00 (modulus) / IP21 (anterior panel) |
|
Numerus ordinis |
9100-00005 |
|
Accesoria |
MMS 6910 (manualis operativa, software configuratio, cables coniunctionis) |
|
Dimensiones |
3×19×12.7 cm |
|
Pondus |
0.3kg |
The MMS6410 est amplificator mensurae bicanalis ex serie MMS 6000 epro, speciatim constructus pro mensuris expansionis absolutae et displacementis per sensus inductivos ut series PR 9350. The MMS6410 accipit transductores semi-pontis, pleni-pontis, et LVDT/RVDT, praebens tam signa statica quam dynamica usque ad 100 Hz. The MMS6410 sustinet calculos summae et differentiae ex utroque canali, permittens observationem expansionis differentialis. Cum redundantibus intritis DC 18…31.2 V, interfacibus communicationis RS 232/RS 485, et constructione calido-intercambiabili, the MMS6410 praebet performancem fidelem pro protectione turbinum et diagnosticis machinarum in arduis ambientibus industrialibus.
Supervisio Expansio Turbinarum – Mensurat expansionem absolutam corporis et axis in turbinibus vaporis, gasi, et hydroelectricis pro protectione contra expansionem thermicam
Dilatatio differentialis – Calculat differentiam inter expansionem rotoris et corporis ut rubos et contactum axiale praeveniat
Mensura Positionis Valvulae – Supervisit positiones cursus valvularum de regula et valvularum servo in systematibus gubernandi turbinum
Mensura Fortitudinis et Momenti Torquentis – Mensurat quantitates physicarum per transductores inductivos configuratos ad sensum fortitudinis vel momenti torquentis
Supervisio Displacementis Angularis – Sequitur positionem angularem aut rotationem per sensorem LVDT/RVDT idoneum
Protectio Pumparum et Compressorum – Supervisit positionem thrust axiali in compressoribus et pumpis centrifugalis ut damnum ad iuncturas praeveniat
Monitoring of Air Gap in Generator – Measures expansion or displacement between stator and rotor in large generators
Calculations of Sum and Difference – Combines two independent channels to derive values for diagnostic functions in complex machinery
Duo canales independens – Each channel operates independently, or channels may be combined to compute sum or difference values
Compatibilitas cum Multis Sensoribus – Accepts half-bridge, full-bridge, and differential transformer (LVDT/RVDT) inductive sensors
Static and Dynamic Signal Outputs – Provides both DC (0…10 V) and dynamic (0…12 Vp) outputs, enabling analysis of both steady-state and transient conditions
Configurable Alarm Limits – Four independently adjustable alarm outputs (two per channel), with configurable hysteresis and delay (0…5 s)
Multiplicator de Acceleratio – Inputus binarius externus permittit limites alarmis multiplicari (1.000…4.999) durante initiatione machinae, ut evitantur tripationes inutiles
Designatio pro commutatione calida – Modulus potest substitui durante operatione sine cessatione systematis, minuens tempus inoperationis
Ingressus Alimentationis Redundantes – Duo ingressus directi 18…31.2 V DC, decouplati per diodos, certificant operationem continuam
Interfacies RS 232 et RS 485 – Configurationis localis per frontem RS 232; bus RS 485 sustinet usque ad 31 modulos (62 canales) pro integratione cum MMS 6800 aut computatris dominis
Diagnostica propria expleta – Supervidet continuo connexionem sensorum, tensiones alimentationis, integritatem configurationis, et temporizatorem vigilis
Exitus galvanice isolati – Exitus currentis et alarmis sunt isolati galvanice ab alimentatione systematis pro immunitate contra rumorem
Alimentatio Sensorum Aequilibrata ad Terram – Minuit sensibilitatem ad rumorem in ambientes industrialis
Verum Mensuramentum Expansionis Differentialis – Aliter quam amplificatores canalissinguli, MMS6410 calculat directe valores summae et differentiae inter duos canales, praebens veram supervisionem expansionis differentialis, quae est essentialis ad praeventiones turbine-rubrum.
Versatilitas Multi-Sensoris – Suffragat sensores semi-pontis, pleni-pontis, et LVDT/RVDT in unico modulo, minuens inventarium partium reservatarum et simplificans mutationes ab systematis antiquis.
Egressus Signali Dynamici Altius-Frequentiae – Praebet egressum sensoris crudum usque ad 20 kHz (cum frequentia portante) simul cum egressu filtrato 100 Hz DC, permittens supervisionem conditionis et analysin diagnosticam simul.
Tecnologia Frequentiae Portantis – Utitur frequentia portante 4.75 kHz cum supply sensore aequilibrato ad terram, offrens immunitatem superiorem ad rumorem in ambientes industrialis electricis turbidis comparata systematibus excitatis DC.
Multiplicator Alarmis Ad Accelerationem – Inputus binary externus permittit scalationem dynamicam liminum alarmis durante initio, eliminans activationes frustraneas dum protectionem integram retinet ad velocitatem operationis.
Integratio MMS 6000 perfecta – Perfecte compatibilis cum systemate analysi et diagnostica epro MMS 6800 et architecturis bus RS 485, permittens systemata monitoris machinarum scalabilia, ab una machina usque ad totam fabricam.
Interchangeabilis calido cum potentia redundante – Designum interchangeabile calido cum inputibus potentiae decouplatis per diodos assurat operationem continuam durante substitutione moduli et manutenzione fontis potentiae.
Q1: Quae genera sensorum sunt compatibilia cum MMS6410?
A1: Ille MMS6410 accipit sensores displacementis inductivos in configurationibus semi-pontis et pleni-pontis, inter quos transformatores differentiales (LVDT/RVDT). Series sensorum epro PR 9350 plene compatibiles sunt, sicut et alii sensores cum characteristicis electricis congruentibus.
Q2: Num MMS6410 potest metiri signa statica et dynamica simul?
A2: Ita. MMS6410 praebet separatas emissiones pro signis staticis (0…10 V) et dynamicis (0…12 Vp). Emissio statica filtratur ad 100 Hz pro observatione statu stabili, dum emissio dynamica praebet signum crassum frequentialis portantis (usque ad 20 kHz) pro analysi vibrationum et transitorum.
Q3: Num duo canales coniungi possunt pro mensurationibus expansionis differentialis?
A3: Ita. MMS6410 potest calculare valores summae vel differentiae ex utroque canali. Haec est necessaria pro observatione expansionis differentialis, ubi differentia inter expansionem rotoris et carapacis critica est pro protectione turbinis.
Q4: Quae est utilitas intritus multiplicatoris pro cursu ascensu?
A4: Intritus multiplicatoris pro cursu ascensu permittit limites allarum multiplicari per factorem configurabilem (1,000…4,999) durante initio machinae. Hoc impedit tripas irritantes causatas a dilatione thermica transitoria durante cursu ascensu et descensu, dum plena protectio servatur ad velocitatem operationis normalis.
Q5: Num MMS6410 praebet detectionem defectuum sensorum?
A5: Etiam. MMS6410 monitorat continuo connexiones sensorum pro circuitibus apertis et cortis, simul cum integritate tensionis supplicis et validitate configurationis. LED viridis «Canalis Clarus» indicat operationem normalem; extinguetur durante defectu, et causae defectus particularis per interfacies RS 232 aut RS 485 legi possunt ad celerem diagnosticam.
Nunc interrogare: [email protected]