| VENDITE | Epistula electronica | Telephonum / WhatsApp |
|---|---|---|
| Iimus Pei | [email protected] | +86 18020776782 |
| Numerus Exemplaris | FMU671 |
| Familia producti | Nivosonic FMU 671/676 |
| Typus Producti | Transmisor de nivel ultrasónico |
| Modus mensurationis | Ultrasonica non-contact continua |
| Variabiles Mensurae | Nivelis et volumen |
| Ingressus Sensoris | Sensoria ultrasonica DU cum sensorio temperaturae |
| Sensorēs Compatibīlēs | DU40, DU41, DU42S/C, DU43S/C, DU44Z, DU46Z, DU73S/C |
| Calibration | Dialogus directus in fronte tabulae aut remotus |
| Analogica currentis emissio | 0/4 à 20 mA |
| Onus Exsulationis Currentis | 500 ohm maxime |
| Exsulsum Tensionis Analogicum | 0/2 ad 10 V |
| Tensio Exire Onus | 2 kohm minimum |
| Limit Relays | 2 independent change-over contacts |
| Relay alarmans | 1 potential-free change-over contact |
| Fail-Safe Mode | Minimum or maximum selectable |
| Puncta linearizationis | Usque ad 30 |
| Fault Output Actions | -10%, +110% or hold last value |
| Fons Potentiae | 24 V DC; 20 to 30 V DC |
| Consumptio currentis | 90 mA typical; 125 mA maximum |
| Conector | DIN 41612 typus F, 30-polus |
| Resistentia Cavi Sensoris | 25 ohm maxime per nucleum |
| Classificatio Relais AC | 2.5 A, 250 V AC maxime |
| Classificatio Relais DC | 100 V DC, 90 W maxime |
| Indicatores Status | 6 LED |
| Display Anterius | LCD cum graphico columnari et campo matriciali |
| Interfacs Remota | Commulog VU260Z aut ZA67 Rackbus gateway |
| TERMINUS EMPTIO | Detalia |
|---|---|
| Minimum quantitas ordinis | 1 piece |
| Pretium | Contactus pro Jim |
| Singula Packaging | Novus Originalis, Sigillatus a Fabrica |
| Tempus Traditionis | 3–7 dies |
| Condiciones solutionis | T/T |
| Shipping modum | DHL / FedEx / UPS / TNT |
| Capacitas Supplicandi | Novus prorsus, in stock |
|
01
Emittit impulsum ultrasonicum Sensor DU connexus impulsum acusticum ad superficiem materiae mittit.
|
02
Aequat echo redientia Transmitter filtrat fitments, reflexiones multiplices, et ecos sparsos.
|
|
03
Calcula nivellem vel volumen Tempus cursus echo convertitur in nivellem mensuratum et volumen vasalis optionalem.
|
04
Deliberat output processus Signales analogicos et relais regulabiles referunt statum mensurationis et alarmarum.
|
|
24 V DC
Copia
|
30 Puncta linearizationis |
2 Relais limitis independens |
| Commissioning directum FMU671 pot calibrari ab su fronte panel. | Suppressione de falsos echo Datos de envelope immagazinatos adjutat ignorar structuras fixas de vassellus. | Supervisione flexibile Illo opera in modo autonomo o per meo de ligamines supervisori Rackbus. |
| 01 | Quales vassellos pote FMU671 mesurar sine contactu con le material? | Illo supporta liquidos e solidos in vassellos de formas varie quando associate con un sensor DU approbato. |
| 02 | Como rejecta FMU671 le echoes ab le accesorios del vassellus? | Suppressione de objectos fixos eleva le limine de detection circa le echoes de interference immagazinatos. |
| 03 | Quales signales analogic pote fornir FMU671? | Outputus eligitur inter 0/4 usque ad 20 mA et 0/2 usque ad 10 V. |
| 04 | Quot puncta linearizationis vasculi FMU671 servat? | Officiale informatio technica stat usque ad 30 puncta referentiae. |
| 05 | Quae est necessaria gamma alimentationis pro FMU671? | Utere 20 usque ad 30 V DC circa nominalem alimentationem 24 V DC. |
| 06 | Quid ante substitutionem FMU671 notandum est? | Salva typum sensoris DU, calibraturam, curvam vasculi, gammam outputus, limina relectorum et actionem fail-safe. |
| GD250W4N | IS23DI0XCD000 | MCHRTF12C0 |
| OBi302 | YPP6000-6R0 | TTSIM-1-24VDC |
| BIP-5000 | SNC-CH110 | DIN-AP3 |
| CL510 | MWR-SH11UN | RRPAE00 |
| EZV516 | QD3900H1 | HEX70B-RX |
| DP2500-R8 | HW100 | HMIX7PR |
| WH30TQG | ITEM3-2000U000080 | NC-540-1-1-5 |
| DL50F/S176 | CPO-RL4 | DGBP-E2CRS |
| SE6104 | HWS600-24/LNT | PGDT04000F020 |
| MCX06D | HD500 | FTD110DBMicro |
| C200HW-NC413 | RKC4.221T-30/TEB | SB-HVAC2-DN |
| PIG00032 | HWS600-48 | DM-TX-4KZ-302-C |
| EX1N32ER | MR16OUT-S3 | PM1200 |