| SALES | PHONE / WHATSAPP | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model Number | FMU671 |
| Product Family | Nivosonic FMU 671/676 |
| Product Type | Ultrasonic level transmitter |
| Measurement Method | Continuous non-contact ultrasonic |
| Measurement Variables | Level and volume |
| Sensor Input | DU ultrasonic sensors with temperature sensor |
| Compatible Sensors | DU40, DU41, DU42S/C, DU43S/C, DU44Z, DU46Z, DU73S/C |
| Calibration | Direct front panel or remote dialogue |
| Analog Current Output | 0/4 to 20 mA |
| Current Output Load | 500 ohm maximum |
| Analog Voltage Output | 0/2 to 10 V |
| Voltage Output Load | 2 kohm minimum |
| Limit Relays | 2 independent change-over contacts |
| Alarm Relay | 1 potential-free change-over contact |
| Fail-Safe Mode | Minimum or maximum selectable |
| Linearization Points | Up to 30 |
| Fault Output Actions | -10%, +110% or hold last value |
| Power Supply | 24 V DC; 20 to 30 V DC |
| Current Consumption | 90 mA typical; 125 mA maximum |
| Connector | DIN 41612 type F, 30-pole |
| Sensor Cable Resistance | 25 ohm maximum per core |
| Relay AC Rating | 2.5 A, 250 V AC maximum |
| Relay DC Rating | 100 V DC, 90 W maximum |
| Status Indicators | 6 LEDs |
| Front Display | LCD with bar graph and matrix field |
| Remote Interface | Commulog VU260Z or ZA67 Rackbus gateway |
| PURCHASING TERM | DETAILS |
|---|---|
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
|
01
Transmit an ultrasonic pulseThe connected DU sensor sends an acoustic pulse toward the material surface.
|
02
Evaluate returning echoesThe transmitter filters fittings, multiple reflections and sporadic echoes.
|
|
03
Calculate level or volumeEcho travel time is converted into a measured level and optional vessel volume.
|
04
Deliver process outputsAnalog signals and adjustable relays report measurement and alarm states.
|
|
24 V DC
Supply
|
30
Linearization points |
2
Independent limit relays |
| Direct commissioningFMU671 can be calibrated from its front panel. | False-echo suppressionStored envelope data helps ignore fixed vessel structures. | Flexible supervisionIt operates stand-alone or through Rackbus supervisory links. |
| 01 | Which vessels can FMU671 measure without contacting the material? | It supports liquids and solids in vessels of varied shapes when paired with an approved DU sensor. |
| 02 | How does FMU671 reject echoes from vessel fittings? | Fixed-target suppression raises the detection threshold around stored interference echoes. |
| 03 | What analog signals can FMU671 provide? | The outputs are selectable between 0/4 to 20 mA and 0/2 to 10 V. |
| 04 | How many vessel-linearization points does FMU671 store? | The official technical information states up to 30 reference points. |
| 05 | Which supply range is required by FMU671? | Use 20 to 30 V DC around the nominal 24 V DC supply. |
| 06 | What should be recorded before exchanging FMU671? | Save the DU sensor type, calibration, vessel curve, output range, relay thresholds and fail-safe action. |
| GD250W4N | IS23DI0XCD000 | MCHRTF12C0 |
| OBi302 | YPP6000-6R0 | TTSIM-1-24VDC |
| BIP-5000 | SNC-CH110 | DIN-AP3 |
| CL510 | MWR-SH11UN | RRPAE00 |
| EZV516 | QD3900H1 | HEX70B-RX |
| DP2500-R8 | HW100 | HMIX7PR |
| WH30TQG | ITEM3-2000U000080 | NC-540-1-1-5 |
| DL50F/S176 | CPO-RL4 | DGBP-E2CRS |
| SE6104 | HWS600-24/LNT | PGDT04000F020 |
| MCX06D | HD500 | FTD110DBMicro |
| C200HW-NC413 | RKC4.221T-30/TEB | SB-HVAC2-DN |
| PIG00032 | HWS600-48 | DM-TX-4KZ-302-C |
| EX1N32ER | MR16OUT-S3 | PM1200 |