Nomen producti: Fornitores Moduli COMMS
Nomen marcae: Ge
Numerus exemplaris: UR 7HH UR7HH
Terra Originis: USA
Warranty: 12 menses
Whatsapp:+86 18159889985
Epistula electronica: [email protected]
Nomen marcae: |
General Electric |
Numerus exemplaris: |
UR 7HH UR7HH |
Terra Originis: |
USA |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
Tempus expeditionis, si in deposito |
Conditiones solutionis: |
T/T |
|
Praepositus Venalium: |
Stella |
|
Mitte epistulam electronicam: |
|
|
Contactus per Whatsapp: |
|
Parameter |
Specificatio |
|
Numerus partis |
UR7HH / UR-7HH |
|
Fabricator |
General Electric (GE) – GE Grid Solutions / GE Multilin |
|
Product Type |
Modulus Communicationis pro Relais Universalibus Seriei UR |
|
Architectura Hardware |
Modulus Expansionis Communicationis Fibrae Multimodalis in Scandentem Insertus |
|
Portūs Fibrae |
2 × connexiones fibrae multimodales ST |
|
Longitudo Undae Opticae |
laser infrarubri multimodalis 820 nm |
|
Maxima Distantia Fibrae |
2 km cum cavo multimodo 62.5/125 μm |
|
Portae Ethernet |
2 × RJ45 (aut 3 × 10/100/1000Base-T, secundum variantem) |
|
Portus Seriales |
RS-485, RS-232 |
|
Celeritas Transferendi Datorum |
Usque ad 1 Gbps (Ethernet); 100 Mbps (per ductum opticum) |
|
Protocolli Admissi |
IEC 61850 Ed. 1 et 2 (MMS/GOOSE), Modbus TCP/RTU, DNP3, IEC 60870-5-104, IEEE C37.118, R-GOOSE |
|
Supportus Redundantiae |
PRP (IEC 62439-3), HSR, duplex introitus electrici, duplex retis calidus-praeparatus |
|
Synchronizatio Temporis |
IEEE 1588 v2 (PTP), SNTP |
|
Capacitas Substitutionis Calidae |
Ita (insertio/remotio in tempore reali) |
|
Temperatura operativa |
–40°C ad +70°C |
|
Temperatura recondita |
–45°C usque ad +85°C |
|
Classis Isolationis |
2500 Vrms isolatio galvanica inter circuitus fibrae et planum dorsale |
|
Fontem electricitatis |
24 V DC nominale (alimentatum e plano dorsali chassidis UR) |
|
Consumptus Electricus |
4,3 W maxime |
|
Dimensiones |
15,9 cm × 18,0 cm × 4,0 cm (fere) |
|
Pondus |
1.2 kg |
|
Montatio |
Ad planum dorsale fixum (scandula chassidis UR) |
|
Conformitas |
IEC 61850-3, IEEE 1613, IEEE C37.90 |
|
Patria Origin |
Civitates Foederatae Americae (CFA) |
The UR7HH est modulus communicandi peritissimus ab GE Grid Solutions (Multilin) ad platformam universalem relais seriei UR elaboratus. In planum dorsale chassidis relais insertus, UR7HH fungitur ut porta principalis rete, quae relais hospitis ad systemata supervisoria per fibras opticas et Ethernet coniungit. Ille UR7HH duos canales communicationis independentes pro redundantia sustinet et tres portas Ethernet, interfacies fibrae multimodales, et plenam praebet adstipulationem protocollorum IEC 61850 editio 1 et 2. Cum synchronisatione temporis secundum IEEE 1588, redundantia PRP, et robusto intervallo temperaturarum a –40°C usque ad +70°C, UR7HH certam inter se commutationem datorum inter relais et automationem substationis etiam in asperis ambibus electricis praebet.
Systemata protectionis et directionis generatorum (G60), quae altam velocitatem communicationis inter relais et SCADA postulant
Protectiones transformatorum (T60/T35) cum architecturis retis fibrosis redundantibus
Protectio differentialis currentis lineae (L90/L30) per conexiones fibrarum multimodorum
Protectio alimentatoris (F60/F35) integrata in systemata automationis substationum basata in IEC 61850
Protectio differentialis omnium busbar (B90/B30) cum protocollo redundantiae parallelae (PRP)
Systemata protectionis motorum (M60) quae exigunt nuntianda GOOSE in tempore reale et coordinationem logicam inter pares
Protectio banchorum condensatorum (C70) et moderator interruptorum (C60/C30) pro substationibus utilitatis publicae
Systemata latiuspansae observationis et imperii (WAMS/WAPC) utentia R-GOOSE ultra stationem subterraneam
Communicatio fibrosa bifurcata: Aptus est duobus portibus fibrosis ST multimodis 820 nm, quae distantiis usque ad 2 km sufficiunt, praebentque transferrationem datorum inter relais immune a rumore et electrica separatione
Tres portus Ethernet independens: Permittit segregationem oneris gravis (exempli gratia, synchrophasorum) a servitiis missionis criticis (GOOSE, MMS) ut effectus latenter possint tolli
Comprehensiva Protocoli Supportatio: Plene certificatus pro IEC 61850 Editionibus 1 et 2 (GOOSE, MMS, Valores Exemplificati), praeterea pro DNP3, Modbus TCP/RTU, IEC 60870‑5‑104, et synchrophasoribus IEEE C37.118.
IEEE 1588 Protocolus Temporis Praecisi (PTP): Eliminat speciales lineas IRIG‑B per sub‑microsecundam synchronisationem temporis directe per rete Ethernet.
Redundantia Sine Interruptione Operis: Favet PRP (Protocolus Redundantiae Parallelae, IEC 62439‑3) et HSR, permittens immutatum transitum ad systema alterum sine interruptione servitiorum communicationis.
GOOSE Rete Transmissibilis (R‑GOOSE): Extendit nuntios GOOSE ultra stationem subterraneam ad applicationes protectionis et dictionis latioris areae (WAPC).
Calidus Substituibilis: Favet insertionem et extractionem vivam ad manutenationem in usu, absque intermissione alimentationis chassidis rellae.
Isolatio Galvanica: isolatio 2500 Vrms inter circuitus fibrosos et planum dorsale impedit differentias potentialis terrae et transitorias impulsum in ambientes alti voltatis.
Duplex Potentia et Rete Redundantia: Duplex ingressus potentiae et duplex calidus‑standby rete certificant operationem continuam etiam si unus e fontibus potentiae aut una ex viis rete deficiat.
Cybersecuritas Completa: Incorporata series CyberSentry™ cum Controle Accessus Basato in Rolis (RBAC), subsidio servitoris AAA (Radius), registro eventuum Syslog, et SNMPv3.
Praebet communicationem altam velocitatem inter relais series UR et systemata SCADA/DCS/HMI per retia Ethernet vel optica fibrosa.
Permittit nuntiationem GOOSE inter pares inter usque ad 16 dispositiva remota UR pro schematibus protectionis distributis (exempli gratia, defectus interruptoris, trippatio transferens, interblocatio).
Convertit interna data protectionis et mensurationis UR in protocollos normatos industriae (IEC 61850, DNP3, Modbus) ad integrationem perfectam cum systematibus controlis tertiorum partium.
Synchronizat plura relais UR intra substationem utendo IEEE 1588 PTP per Ethernet, eliminans separatam wirationem temporalem et meliorans accuratiam temporis eventuum ad ±1 μs.
Rete redundantiam per PRP et HSR regit, pacheta data in duobus rete independenter duplicans ut unum pachetum datum semper ad dispositivum recipiens sine mora temporis perveniat.
Fluxus dati synchrophasorum (PMU) secundum normas IEEE C37.118 et IEC 61850‑90‑5 directe ex relais protectionis ad concentrales datos phasorum (PDCs) transmittit.
Routable GOOSE (R‑GOOSE) suffragat ut nuntii LAN substationis per retia areae latissimae pro schematibus protectionis provectis extendantur.
Diagnostica insita praebet quae niveles potestatis opticae, valetudinem connexionis, statum defectus transceptorum, et resultata experimentorum sui ipsius observant ut cura proactiva fieri possit.
Exhibet integratum coloratum monstrum graphicum (variatio CPU‑montata) pro visione locali diagrammatum phasorum, summariorum eventuum, et status logicae protectionis absque instrumentis externis.
Q1: Ad quid UR7HH utitur?
A1: Ille UR7HH est modulus communicationis qui praebet retia fibrae et Ethernet pro universalibus relectoribus seriei GE Multilin UR, permittens nuntios IEC 61850 GOOSE, integrationem SCADA, et redundantem communicationem in stationibus electricis.
Q2: Quot portus fibrae habet UR7HH, et quam longam distantiam adtinet?
A2: UR7HH habet duos portus fibrae multimodales ST operantes ad 820 nm, qui adtinent distantias communicationis usque ad 2 km cum cavo fibrae multimodalis 62,5/125 μm.
Q3: Num UR7HH topologias retis redundantis adtinet?
A3: Ita. UR7HH adtit PRP (Parallel Redundancy Protocol, IEC 62439‑3) et HSR, praebens redundancy sine tempore intermissionis pro applicationibus protectionis missionis criticae.
Q4: Quae protocolla UR7HH adtinet?
A4: UR7HH adtit IEC 61850 Editio 1 et 2 (GOOSE, MMS, SV), DNP3, Modbus TCP/RTU, IEC 60870‑5‑104, synchrophasores IEEE C37.118, et GOOSE transmissibile (R‑GOOSE).
Q5: Num UR7HH commutabilis est dum operat?
A5: Ita, UR7HH sustinet insertionem et removalm vivam, permittens substitutionem moduli absque intermissione alimentationis chassidis relais UR vel interruptione aliarum functionum systematis.
Interroga nunc: [email protected]