Magaca Alaabta: Oo ka saabsan COMMS Module
Magaca Brand: GE
Lambarka Modelka: UR 7HH UR7HH
Dalka kaleyska: Dhalinyarada Amerikanka
Damaanad: boqortooyada 12 Bulsho
Whatsapp: +86 18159889985
Iimaylka: [email protected]
Magaca Brand: |
General Electric |
Lambarka Modelka: |
UR 7HH UR7HH |
Dalka kaleyska: |
Dhalinyarada Amerikanka |
Furaha Talaalada: |
Cusub oo ah orijinaalka, oo ku dhaqmayn khasabta ah |
Wakhtiga aad ugu yaraysid: |
Wakhtiga soo guurinta marka la jirto magaalo |
Shurtida Casirada: |
T/T |
|
Mudirka Biyaha: |
Stella |
|
Ii email: |
|
|
Xiriirka WhatsApp: |
|
Meesha |
Faahfaahinta |
|
ISIMKA QOOR |
UR7HH / UR-7HH |
|
Sameynta |
General Electric (GE) – GE Grid Solutions / GE Multilin |
|
Nooca Alaabta |
Mooduulka Xiriirka ah ee Ur Kooxda Isku Qorshaynayaasha Aasaasiga ah |
|
Quruxa Qalabka |
Mooduulka Dib u Ceynka Xiriirka Quruuxa ee Ku Darayaa Soodo |
|
Kuwa Fiiberka |
2 × Qaabaha Quruuxa ee Isku Qorshaynayaasha Quruuxa |
|
Dheeradda Quruuxa |
laser ka dhexeeya quruuxa 820nm ee ka dhexeeya quruuxa |
|
Dheeradka Ugu Yar ee Quruuxa |
2 km leh kable ee ku jira 62.5/125μm multimode |
|
Mafahimaha Ethernet |
2 × RJ45 (ama 3 × 10/100/1000Base-T, ku yaal marka laga eegayo nooca) |
|
Ports-ka Serial |
RS-485, RS-232 |
|
Hastiga Qorshaha Macluumaadka |
Ugu yar 1 Gbps (Ethernet); 100 Mbps (qorshaha fiber) |
|
Protocols Laga Wadaagay |
IEC 61850 Ed. 1 & 2 (MMS/GOOSE), Modbus TCP/RTU, DNP3, IEC 60870-5-104, IEEE C37.118, R-GOOSE |
|
Talada Isku dhafan |
PRP (IEC 62439-3), HSR, gacanta laba oo la isticmaalo, laba shabakad oo la isticmaalo mar dambe |
|
Sincroniisaya Kooxda Waaqti |
IEEE 1588 v2 (PTP), SNTP |
|
Xaqa Xidhiidhka Hot-Swap |
Haa (ku dar kara ama ka saar kara mar dambe) |
|
Caano Caano |
–40°C ilaa +70°C |
|
Dhammaadka ammarta |
–45°C ilaa +85°C |
|
Qodobka Isku Dhowaanka |
2500 Vrms isu qaybinta galbaaniga ee kable ee fiber iyo backplane |
|
Koronto |
24 V DC ugu dambaysa (loogu dhisnay UR chassis backplane) |
|
Qaybta Elektrikada |
4.3 W ugu yar |
|
Cabbirrada |
15.9 cm × 18.0 cm × 4.0 cm (tahsili) |
|
Miisaanka |
1.2 kg |
|
Socod |
Laguu dhisay backplane (UR chassis slot) |
|
Xaqiijinta |
IEC 61850-3, IEEE 1613, IEEE C37.90 |
|
Dalka guurka |
Maraykanka (USA) |
Waxaa UR7HH waa moduulka caawinada ka badan ee la sameeyay GE Grid Solutions (Multilin) si loo isticmaalo platformka UR Series universal relay. Laga dhisay backplane ee relay chassis, UR7HH wuxuu noqonayaa xubnaha ugu muhiimseeda ee caawinada, ku dhaqanaya relay-ka aasaasiga ah iyo nidaamka caawinada ee ku saabsan fiber iyo Ethernet. UR7HH wuxuu ku wada leeyahay laba xubnaha caawinada la isku dayeen kara oo ka dhigayaa xubnaha la isku dayeen kara, saddex port Ethernet, xubnaha fiber oo ka dhigayaa laba jir, iyo taliyadda guud ee IEC 61850 Ed. 1 & 2. Marka la isticmaalo IEEE 1588 caawinada waqtiga, PRP redundancy, iyo qaybta gacanta ah ee –40°C ilaa +70°C, UR7HH wuxuu diyaarinayaa in data exchange-ka mid-relay ay noqdo si cad iyo in automation-ka substation ay noqdo si cad, haddana marka ay la jiro xaaladaha gacanta ah ee elektrik.
Nidaamka caawinada iyo ka shaqeynta generator-ka (G60) oo doonaya caawinada sare ee mid-relay ilaa SCADA
Xinaya transformer (T60/T35) ku yaal oo leh taariikhda qaybta ka duwan ee xagga koonfureedka
Xinaya xagga dhexe ee jirka (L90/L30) ku yaal oo leh xagga koonfureedka ka duwan ee xagga koonfureedka
Xinaya xagga qaybta (F60/F35) la gudbiyey nidaamka iyo xagga koonfureedka ee substation ee la isticmaalo IEC 61850
Xinaya xagga busbar ee dhexe (B90/B30) ku yaal oo leh xagga koonfureedka parallel redundancy protocol (PRP)
Nidaamka xinaya motor (M60) oo u baahan yahay fikradaha GOOSE ee mararka ah iyo taajilka loogu talagalay xagga koonfureedka
Xinaya xagga capacitor bank (C70) iyo controllerka breaker (C60/C30) ee substationka ka soo bixiya
Nidaamka heerka weyn ee raadinta iyo xiriirka (WAMS/WAPC) oo isticmaala R-GOOSE ka horreeya substationka
Xagga koonfureedka ka duwan ee fiber: La qaybinayay laba port ka duwan ee fiber ST ee multimode ee 820nm oo la isticmaalo doorooyinka ugu badan 2 km, oo sidaas daraaddeed u siiyaa xagga koonfureedka ka duwan ee xagga koonfureedka oo aan lahayn xarash iyo isku xidhiidhka elektrik
Labo port Ethernet oo ka duwan: Wuxuu kaga dhigaa isku qorsho ka saarida xoolaha kuwa badan (tusaale ahaan, synchrophasors) ka mid ah isticmaalka muhiimka ah (GOOSE, MMS) si ay ugu dhaqaaqin lahayn taajabka oo ka dhigan karaa xadka lagu soo saaray.
Xusuus leh ee Xeerarka: Wuxuu ku jiraa talaabooyinka IEC 61850 ee ka kooban (GOOSE, MMS, Sampled Values), iyo DNP3, Modbus TCP/RTU, IEC 60870-5-104, iyo IEEE C37.118 synchrophasors.
IEEE 1588 Xeerka Waaqtiye Awoodda (PTP): Wuxuu ka saaray xeerka IRIG-B ee kuwa ku jiraan si ay ugu dhaqaaqin lahayn waaqtiye awoodda ka yar marka micrusekond ka dib, kuwaas oo ku dhisay in ka badan Ethernet network.
Isku daynta aan la jirin dhammaan: Wuxuu kaga dhigaa PRP (Xeerka Isku Daynta Kuwa Kooxiga, IEC 62439-3) iyo HSR, waxay kaga dhigtaa isku daynta aan la jirin dhammaan, aan la jirin dhammaan isticmaalka xiriirka.
GOOSE ee la xidhiidha (R-GOOSE): Wuxuu ku badbaadi doonaa fikradaha GOOSE ka hor joogga substation si ay ugu dhaqaaqin lahayn isticmaalka xiriirka iyo xiriirka ka badan (WAPC).
Waxyaabaha Ku Daran Kaliya: Wuxuu kaga dhigaa isku daynta iyo ka saarida mara hore ee isticmaalka mara hore, aan la jirin dhammaan ku dhisay in ka badan relay chassis.
Ku Darsho Galvaanik: isolation 2500 Vrms ka mid ah xariiqaha fiber iyo blockada backplane waxay ku dhaqaaqinayaan isku dhafan kasta oo dhulka iyo xadka xiritaanka (surge transients) ee xagga joogta gacmaha sare.
Dhismaha Laba Jihadi iyo Laba Shabakadda: Jihadi laba iyo shabakadda laba ee hot-standby waxay hubi doonaan shaqsiyada si joojinta ah, haddii jihadi kuu noqdo ama shabakadda kuu noqdo.
Amaanadda Cyber sida guud ahaantii: CyberSentry™ ku dhex mara oo ku saabsan Qodobada Xaqiijinta Kaalinta (RBAC), taageerada AAA (Radius), taageerada habaraha Syslog, iyo SNMPv3.
Waxay sabaabilaan kala-celinta dheerka ugu yar ee UR series relays iyo sistemaadaha SCADA/DCS/HMI la xidhiidh Ethernet ama shabakadda fiber optical.
Waxay sameeyaan xiriirka GOOSE ee laba-taas oo ku dhex mara ee ururka UR ee kaalinta 16 ee kaalinta dib ugu yar ee ku saabsan qodobada kaalinta kaalinta (tusaale ahaan: xadka xiritaanka, xadka xiritaanka, iyo xadka xiritaanka).
Waxay badbaadinayaan wararka kaalinta iyo wararka maqashka UR ee dhexeeya kuwa caasimka (IEC 61850, DNP3, Modbus) si ay ugu yar yeen doonaan xidhiidhka sistemaadaha kaalinta ee kaalinta.
Wada shaqeya qaybaha UR ka badan ee ku jira xafiye waa isticmaalaya IEEE 1588 PTP ku saabsan Ethernet, taasoo ku dhaqameysa xariirka la isku dhafan oo keliya iyo ku caawinaa saxda qaabka waqtiga hadalka ilaa ±1 μs.
Uga raacaya kuwa soo noqonkooda ee shabakadda iyada oo loo isticmaala PRP iyo HSR, oo ku dhaqameysa waraqaha xogta ka dib ugu yar ee shabakadda laba ee leh isku dayn, sidaas daraaddeed waxaa la heli karaa waraqaha xogta ka dib ugu yar ee ku jira qofka la xogta ku soo galey, oo aan lahayn xadgudubka waqtiga.
Uu soo diri koorsooyinka synchrophasor (PMU) ee la xogta ku jira IEEE C37.118 iyo IEC 61850‑90‑5 ka dib marka laga soo diri qaybaha la xogta ku jira (PDCs).
Waxay tuuranta GOOSE ee la xogta ku jira (R‑GOOSE) inaad ugu yeedesho habka xogta ku jira xafiye ee la xogta ku jira shabakadda weyn ee ku saabsan hababka la xogta ku jira oo ka weyn.
Waxay tuuranta fahminta ka dib ee ku jira (onboard diagnostics) ee la xogta ku jira qaabka xogta opticaal, xafiye ee ku jira, xafiye ee ku jira qaybaha la xogta ku jira, iyo tijaabtii ka dib ee ku jira si ay ugu hortagto maamulka ka dib.
Waxay tuuranta qoraalka midig ee la xogta ku jira (CPU‑mounted variant) ee la xogta ku jira si ay ugu xiriiraan qaabka phasor, taariikhda hadalka, iyo xafiye ee ku jira hababka la xogta ku jira, aan lahayn qaybaha la xogta ku jira.
Su’aal 1: UR7HH waa la isticmaalaa maxaad?
Jawaab 1: UR7HH waa moduulka xiriirka oo kaabaya shabakada fiber iyo Ethernet ee geerka UR ee GE Multilin, waxay uga saraysaa fikradaha IEC 61850 GOOSE, xiriirka SCADA, iyo xiriirka substation oo la xariiraan karo.
Su’aal 2: UR7HH waa ku jira qaybaha fiber kamaa, iyo qaabka uu uga saraysaa?
A2: Waa UR7HH wuxuu leeyahay laba qaybaha fiber ST oo ka dhacaya multimode, oo ku shaqeynaya 820nm, waxay uga saraysaa qaabka xiriirka had ii 2 km oo la isticmaalo cableka fiber multimode ee 62.5/125μm.
Su’aal 3: Ma UR7HH wuxuu taageeray qaabka shabakada la xariiraan karo?
Jawaab 3: Haa. UR7HH wuxuu taageeray PRP (Protocolka Xariiraan Kuma Dhaari, IEC 62439‑3) iyo HSR, waxay siiyaan xariiraan kuma dhaari ah ee siinayn karaa wixii la xariiraan karo ee ka badan in ay la isticmaalo xiriirka caawinaadka.
Su’aal 4: Ma UR7HH wuxuu taageeray protocolka?
Jawaab 4: UR7HH wuxuu taageeray IEC 61850 Ed. 1 & 2 (GOOSE, MMS, SV), DNP3, Modbus TCP/RTU, IEC 60870‑5‑104, IEEE C37.118 synchrophasors, iyo Routable GOOSE (R‑GOOSE).
Su’aal 5: Ma UR7HH wuxuu noqon karaa isku baxa ama isku gudbaya?
A5: Haa, UR7HH waxay ku xidhan tahay in la gudbin karo iyo ka saar karo mara, oo waxay siiyaan in module-ka loo badalo isla markii UR relay chassis-ka aan la isticmaalo ama aan la joojiyo qaybaha kale ee shakhsiyaadka.
Ogaada Hadda: [email protected]