The F3322 is a 16-channel digital output module from HIMA's HIQuad series, engineered for safety-critical applications within HIMA H41q and H51q safety PLC systems . The F3322 provides transistor outputs configurable as open-collector or push-pull, supporting resistive and inductive loads up to 0.5 A per channel . With SIL 3 certification, ≥2.5 kV isolation, per-channel diagnostics, and failsafe behavior upon L-supply loss, the F3322 delivers reliable, high-integrity output control for emergency shutdown (ESD), fire & gas (F&G), and burner management systems (BMS) .
Digitale Outputum Actuatio – Converts logic commands into 16 independent digital output signals (0 or 1) to control relays, solenoids, actuators, and indicators
Conversio oneris – Drives resistive loads (e.g., heaters), inductive loads (e.g., solenoids, motor starters), and lamp loads up to 12 W per channel
Failsafe Behavior – Upon L‑supply break, all outputs are immediately de‑energised (no output signal), ensuring a safe state
Short‑Circuit & Overload Protection – Built‑in current limiter (>550 mA trip point) protects the module and field wiring
Diagnostics Systematis – Per‑channel self‑diagnostics with independent Power/Error LED indicators for rapid troubleshooting
16 canales exirentes independens – High‑density digital output capability in a compact 4 TE footprint
Two Output Modes – Configurable as open‑collector (for relay/contact loads) or push‑pull (for higher current LED and logic loads)
Certificatio de incolumitate SIL 3 – Certificatus a TÜV secundum IEC 61508 pro systematibus instrumentorum tutelarum usque ad SIL 3 / AK 7
Alta Isolatio Canalium – Isolatio ≥2,5 kV DC inter outputs et systema, quae propagationem defectuum prohibet
Comportamentum Output Tutelare – Outputs de-energizantur cum amissione supply L, ut statum tutum assecurant
Robustum Praesidium – Outputs contra curtum circuitum muniti, cum puncto trip current limiter >550 mA
Diagnostica Plena – Diagnostics propria per channellum, cum indicibus status LED independentibus pro Alimento / Errore
Capax commutationis calidae – Adiuvat substitutionem moduli in linea sine intermissione systematis
Operatio in Latis Temperaturis – Gradus industrialis ab –25°C usque ad +70°C
Montatio – Installe modulum F3322 in standardi 19″ Eurocard rack (formae factoris 6U) cum supportu hot-swap . Modulus occupat 4 TE spatium rack.
Densitas Moduli Maxima – Maximum 10 moduli F3322 plene onerati in subrachis I/O inscribi possunt .
Planificatio Capacitatis Oneris – Onus totale simulaneum exire non debet 8 A (50% de 16 × 0,5 A) . Certificare ut fusibilis standardis rachis (4 A, lentus) ad onus totale idoneus sit .
Wiring Contrahentes – Usare terminales connexionis bipolares designatas pro singulis canalibus exirentibus. Pro confectionibus cabilorum, videre Z 7136 / 3322 / C. / P2 conectoris cabilis cum connexione bipolari et notis ductuum.
Specificazioni del Cavo – Longitūdō maximā lineae: 750 mm ; typus cāpitis recommendātus: LiYY 16/32 × 0.5 mm² .
Fontem electricitatis – Hoc modulō requīrītur 24 VDC alimentātiō campī et 5 VDC alimentātiō lōgicā ab ānulō dorsālī .
Fusio – Rāmus I/O saepe praeditus est fūsībile lentum 4 A pro grūppō modulōrum .
Q1: Quae est cūrrentia oneris maxima per canālem ūnīus exītūs?
A1: Ĉiu el la 16 kanaloj subtenas maksimuman daŭran ŝarĝan kuranton de 0.5 A (500 mA) je 24 VDC.
Q2: Ĉu ĉiuj 16 eligoj povas esti uzataj je plena ŝarĝo samtempe?
A2: Ne. La tuta samtempa eliga ŝarĝo ne devas superi 8 A (50% de 16 × 0,5 A). Superi tiun limon povus troŝarĝi la fonton de elektra energio .
Q3: Kio okazas se la L‑fonta kablo rompiĝas?
A3: La modulo tuj malaktivigas ĉiujn eligajn signalojn – celita sekureca funkcio por garantii malsukces-safan staton .
Q4: Kiom da F3322 moduloj povas esti instalitaj en unu I/O-subraketo?
A4: Maximum number of 10 moduli F3322 plene onerati may be installed per I/O subrack to avoid overloading the power supply .
Q5: Is the F3322 suitable for safety-critical applications?
A5: Yes. The F3322 is SIL 3 certificatus secundum IEC 61508 (TÜV) and features safety isolation, short-circuit proof outputs, and failsafe behaviour upon L-supply loss, making it ideal for ESD, F&G, and BMS applications .