Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Nomen
Telephōnum mōbile
Nōmen societātis
Notula
0/1000

Rockwell

Pagina Prima >  Producta >  Rockwell

Allen Bradley MicroLogix™ 1200 Controllerēs Programmābiles 1762-L40BWA In stipite

Nomen producti: Variabilis Frequentiae Impulsor AC

Nomen marcae: Allen Bradley

Numerus exemplaris: 1762-L40BWA

Terra Originis: USA

Warranty: 12 menses

Whatsapp:+86 18159889985

Epistula electronica: [email protected]

Appurtenance:
  • Conspectus
  • Contactus pro citatione
  • Specificationes
  • Descriptio
  • Usus
  • Eigenschaften
  • Functiones
  • FAQ
  • Producta Commendata

Conspectus

Nomen marcae:

Allen Bradley

Numerus exemplaris:

1762-L40BWA

Terra Originis:

USA

Particularia impaquetandi:

Originales nova Officina Sigillata

Tempus solutionis:

Tempus expeditionis, si in deposito

Conditiones solutionis:

T/T

Contactus pro citatione

Praepositus Venalium:

Stella

Mitte epistulam electronicam:

[email protected]

Contactus per Whatsapp:

+86 18159889985

Specificationes

Parameter

Specificatio

Fabricator

Allen-Bradley / Rockwell Automation

Product Type

MicroLogix 1200 Programmabilis Logicae Controller (PLC)

Numerus partis

1762-L40BWA

Potentia Input

120/240 V AC (-15 %, +10 %), 47–63 Hz

Memoria Usoris

programma 4 KB, data 2 KB

Numerus Entratarum

xXIV introitus digitales

Typus Ingressus

(20) normales 24 V DC ad sumendum/ad emittendum; (4) celeres 24 V DC ad sumendum/ad emittendum

Numerus Exitus

16 exsufflationes rellae

Typus Exitus

Relay, forma A (normaliter apertum)

Maxima Expansio I/O

Usque ad 6 modulos expansionis / 136 puncta I/O

Communicatio Portus

RS-232/RS-485 isolatum

Communication Protocols

DF1 semiduplex, Modbus RTU, ASCII

Real-time horologium

Optativum (requirit modulum memoriae)

Consumptio potentiae

82 VA maximum

Impetus Initialis Alimentationis

120 V AC: 25 A per 8 ms

Dimensiones (A × L × P)

90 mm × 160 mm × 87 mm

Pondus

Circa 1,1 kg (2,4 lb)

Temperatura operativa

0 °C ad +55 °C (32 °F ad 131 °F)

Temperatura recondita

−40 °C usque ad +85 °C (−40 °F usque ad +185 °F)

Humiditas relativa

5 % ad 95 % nōn condēnsāns

Vibratio

10–500 Hz, 5G, 0,030 in. a vertice ad verticem

Percussio

In usu: 30G; Non in usu: 50G

Certificatio ab institutione

UL 508, C-UL, Classis I Divisio 2 Gruppi A–D

Blocculus terminalem

Removibilis (RTB)

Montatio

Mons ad rilum DIN aut ad tabulam

Descriptio

The 1762-L40BWA est programmabilis logicus controller MicroLogix 1200, 40‑punctus, ab Allen‑Bradley, ad usus industriales compactos atque potentissimos designatus . Hoc 1762-L40BWA unitas habet viginti quattuor intrōs digitāles (viginti commūnēs et quattuor celerēs 24V DC) et sedecim extrōs relēctorum . The 1762-L40BWA expansionem ad 136 puncta I/O per sex mōdulōs expansionis 1762 admittit . Cum memoria utīlis 4 KB, portū communicātiōnis RS‑232/RS‑485, et fōrmātō Modbus RTU subiectō, 1762‑L40BWA solūtiōnem ōptimam pretiī ad contrōlum machīnarum et prōcessuum praebet .

Usus

  • Contrōlum machīnarum et automātiōnem

  • Regulatio Processus et Observatio

  • Systemata Automationis Aedificiorum

  • Commoditas Materiarum et Systemata Fasciarum

  • Machinae ad conglutinandum

  • Controlus pompae et ventili

  • Telemetrīam remotam et acquisītiōnem dātōrum (Modbus RTU)

Eigenschaften

  • Spatium compactum 40 puncta I/O in formā compāctā

  • Intrōs Celerēs : Quattuor celeres intrōs 24 V directī currentis ad numerandum altam velocitātem et capiendum pulsūs

  • Internus altīs velocitātis numerātor : Numerātor independentis 20 kHz

  • Blocs terminales amovibiles : Simplificat connexiōnēs et cūram

  • Expandī potest : Ad usque sex mōdulōs 1762 expansionis I/O suffragat

  • Plures protocolli communicationis : DF1, Modbus RTU, et ASCII

  • Horologium reale : Optiōnālis (cum mōdulō memoriae)

  • Adjustmentēs per trimpot : Duo interna trimpotentiōmetra ¾ vōlūtī

  • Ad loca periculosa aptus : Certificatus Classis I, Divisio 2

Functiones

The 1762-L40BWA exequitur programmatum logicam scalarem a usu definiendam ad processus industriales et machinas regendos. Signa intrantis ex instrumentis agri (sensoribus, interruptoribus) legit, logicam tractat, et instrumenta extrantis (relais, contactores) activat . Internus alti cursus numeratores impulsum celerem tractat, dum porta RS-232/RS-485 communicationem cum HMIs, machinis, et systematibus SCADA per Modbus RTU permittit . Moduli expansionis systemati licent ut usque ad 136 puncta I/O pro applicationibus maioribus crescat .

FAQ

Q1: Quae est differentia inter 1762-L40BWA et 1762-L40BXB?
A1: Uterque est controller MicroLogix 1200 punctorum 40. 1762-L40BWA habet 16 extrantes relais, dum 1762-L40BXB habet mixtam configurationem extrantium relais et FET (solid-state) .

Q2: Quae est tensio intrantis quae 1762-L40BWA requirit?
A2: 1762-L40BWA accipit 120/240 V AC (-15 %, +10 %) ad 47–63 Hz .

Q3: Quot moduli expansionis I/O 1762-L40BWA sustinere potest?
A3: Ille 1762-L40BWA sustinere usque ad sex modulos expansionis I/O 1762 potest, ad summam maximam 136 puncta I/O .

Q4: Quae protocolla communicationis 1762-L40BWA sustinet?
A4: 1762-L40BWA sustinet protocolla DF1 semiduplex, Modbus RTU et ASCII .

Q5: An 1762-L40BWA horologium veri temporis habet?
A5: Horologium veri temporis facultativum est et modulum memoriae requirit .