Petite Gratuito Pretium

Noster legatus te brevi continebit.
Epistula Electronica
Nomen
Telephōnum mōbile
Nomen societatis
Nuntius
0/1000

Prosoft

Pagina Prima >  Producta >  ROCKWELL >  Prosoft

PROSOFT MicroLogix MVI94-MCM Mōdulus Communicātiōnis Modbus Dominus/Servus In Stōcō

Nomen producti: Modulus Communicationis Magistri/Servī Modbus

Nomen marcae: Prosoft

Numerus exemplaris: MVI94-MCM

Terra Originis: USA

Warranty: 12 menses

Whatsapp:+86 18159889985

Epistula electronica: [email protected]

Appurtenance:
  • Conspectus
  • Contactus pro citatione
  • Specificationes
  • Descriptio
  • Usus
  • Eigenschaften
  • Functiones
  • FAQ
  • Producta Commendata

Conspectus

Nomen marcae:

Prosoft

Numerus exemplaris:

MVI94-MCM

Terra Originis:

USA

Particularia impaquetandi:

Originales nova Officina Sigillata

Tempus solutionis:

Tempus expeditionis, si in deposito

Conditiones solutionis:

T/T

Contactus pro citatione

Praepositus Venalium:

Stella

Mitte epistulam electronicam:

[email protected]

Contactus per Whatsapp:

+86 18159889985

Specificationes

Parameter

Specificatio

Numerus Exemplaris

MVI94-MCM

Product Type

Modulus Communicationis Magistri/Servī Modbus

Forma Factor

Singulus Fissura — 1794 Flex I/O dorsalis planum compatibilis

Montatio

Installetur in MVI94 Flex I/O basi; basis in 35 mm DIN-rail montatur

Onus Electricum Planum Posticum

20 mA ad 5 V DC

Externa Potentia Requirimenta

12–24 V DC, 340–170 mA (cursus trahitur secundum tensionem intrantem; 12 V DC trahit ~340 mA, 24 V DC trahit ~170 mA)

Temperatura operativa

0°C ad 55°C (32°F ad 131°F)

Temperatura recondita

−40°C ad 85°C (−40°F ad 185°F)

Impactus (in usu)

30 g

Impactus (non operans)

50 g

Vibratio

5 g ab 10 Hz ad 150 Hz

Humiditas relativa

5 % usque ad 95 % (sine condensatione)

Indicatores LED

Status moduli, status transmigrationis dorsalis plani (U1 flavescens), status applicationis, activitas portus Modbus magistri (PRT2 viridis), activitas portus configurationis (PRT1 viridis), status erroris (U2 flavescens)

Portus Configurationis (PRT1)

Mini-DIN8F, RS-232 tantum, manuale coniungendi signum. Exigit inclusum adaptatorem a Mini-DIN8M ad DB-9M.

Portus Applicationis (PRT2)

Mini-DIN8F, iunctura-selectibilis RS-232/422/485, isolatio optica 500 V ab imo tabulato

Formatum Configurandi Documenti

Textus simplex (.CFG) editus quocumque textu editoris; utitur protocollo Ymodem pro transfertu documentorum per emulatorum terminalium (exempli gratia, HyperTerminal) ad velocitatem 57 600 baud

Bibliotheca Virtualis Modbus

A user definitum, usque ad 3 996 registra (Maximum Register: 1 ad 3996)

Data Block Transfer (BT)

BT Legere Numerum Registri et BT Scribere Numerum Registri: 12 ad 3996 registra; numerus blocorum esse debet ≥2 ad rectam transfertam datorum ab imo tabulato

Dimensiones (Modulus cum Basio)

3,7 H × 3,7 L × 2,7 P pollicum (94 × 94 × 69 mm)

Pondus

0,44 librae (fere)

Certificationes

CE, cUL

Conformitas Regulatoria

RoHs Conformis

Descriptio

The PROSOFT MVI94-MCM est modulorum communicationis ad unum interstitium pro Rockwell Automation 1794 Flex I/O modulus MVI94-MCM fungitur ut porta inter dispositiva Modbus RTU vel ASCII et planum dorsale Flex I/O modulus activus qui perquirit usque ad centum iussa in dispositiva servilia, Dominus Modbus aut ut Servus Modbus , ut magister remotus ad omnes datos in sua virtuali Modbus-archiva accedere possit . Cum memoria plene ab utente definita et subsidio usque ad 5 000 registra, PROSOFT MVI94-MCM flexibilem et fidam solutionem pro integratione automationis veteris praebet .

Usus

Integratio veteris Modbus-apparatus in modernos Flex I/O-systematos

Communicationes SCADA ut Modbus-servus-porta

Concentratio dati — multos Modbus-servos in unum Flex-processorem colligens

Oil & Gas Pipelines et platformas maritimas

Processus ciborum, metallurgia, et fabricatio papyri industriae

Tractatio Aquae/Aquarum Sordidarum — connectens impulsores frequentialis variabilis (VFDs), metra fluxus, et transmittentes pressionis

Aedificiorum automatio — coniungens regulatores HVAC et metra energiae ad processorem Flex I/O

Applicationes Enron/Daniel in virgula flottante (monitoring limitum bateriarum, concentratio datum transfusionis custodialis)

Eigenschaften

designum Flex I/O unius interstitii 1794 — installatur in quolibet interstitio plani dorsalis Flex I/O

Architectura duplex portarum — PRT1 pro configuratione/debug (RS-232), PRT2 pro applicatione Modbus (RS-232/422/485)

Optimatio petitionum a magistro — saepius non interroga servos qui habent problemata communicationis, quod efficit rete efficacius

Usus-definibilis virtualis Modbus databasis — magnitudo, contentum, et structura omnino configurabilis

Usque ad centum iussa Modbus per portam magistri

Favet protocollis Modbus RTU et ASCII

Tractatio datorum in virgula flottante incluse Flottans Enron/Daniel favens adnotationi «unus adlocatus = unum 32-bit REAL»

Coda eventuum in tabulato — logica scalae potest emittere singula iussa (Event Blocks 1000–1255) aut plura iussa (Command Blocks 2001–2006)

Diagnostica incorporata – Indicatores status LED + systema menū portūs debug ostentans numerōs errorum vivōs, listās status servōrum, et analysatōrem dātōrum ad capiendam trānsmissionem

Modus analysatoris dātōrum – vidēre omnia octēta trānsmīsa et accepta in portū applicationis; notae temporāles ē 1 ms ad 100 ms seligibiles

Memoria Flash ROM / Compact Flash (CF) – fīlum configurātiōnis et opțiōnālis cārta CF ad archīvandōs usūs

Reiniciātiō calida (9998) et reiniciātiō frīgida (9999) – blocī reinitiātiōnis sōftware et hardware ex logica scalarī aut ex terminalī debug excitātī

Modus transmissiōnis directae – ad praecepta Modbus scribendī (functionēs 5, 6, 22) quae ad hunc modulum diriguntur, pergitur directē ad processōrem Flex

Functiones

Bibliotheca Virtualis Modbus — area centralis memoriae (usque ad 3 996 registra) quae fungitur interfacie inter dorsalem Flex I/O et dispositiva remota Modbus

Functio dominii Modbus — portus configuratus (PRT2) iussa activa emittit ex elencho iussorum definito ab utente ad dispositiva servilia Modbus

Functio servilis Modbus — portus respondet petitionibus Modbus ingressis a domino remoto, permittens aditum ad quodlibet datum in bibliotheca virtuali

Commercium datorum per blocos — paginae bus Flex I/O data inter bibliothecam virtualem Modbus moduli et processorem per imagines intrantium et extrantium moduli. Singula commercia utuntur blocis sex-vocabulorum, quorum codices identificationis variant ab 0 ad 666

Bloci eventuum et iussorum — processus singula iussa excitare potest (Bloci Eventuum 1000–1255) aut usque ad sex iussa in quaestionem impellere (Bloci Iussorum 2001–2006) ex logica scalaris

Index errorum imperatorum – quilibet imperator in indice habet codicem statūs/errōris; index ubique in virtuālī Modbus databāse pōnī potest

Index statūs servōrum – statum communicātiōnis usque ad 256 dispositīvōrum Modbus servōrum per portam dominī tenēt (0 = inactivus, 1 = activus/successfulis, 2 = suspensus/defectus communicātiōnis)

Instrumentum analysātōris dātōrum – in menū portae debug integrātum; trānsmissiōnem/receptiōnem octetōrum in tempore rēctō ostendit cum signīs speciālibus: pro datīs trānsmissīs, pro datīs receptīs, pro trānsitiōnibus RTS, et pro notīs temporālibus

Configūrātiō per fīlem textūālem simplicem – omnia parametra in fīlō .CFG statuuntur et per emulatorēm terminālis per prōtocolum Ymodem adfertur

FAQ

Q1: Num MVI94-MCM PROSOFT adhūc in prōductiōne est?
A1; Non. The MVI94-MCM officiāliter desinere factus a ProSoft Technology . Hoc compendium ad usum praesentium utentium praebetur. Ad consilium de substituendis partibus, ad distributorem tuum confugias.

Quaestio 2: Num modus MVI94-MCM externam vim requirit?
A2: Ita. Modus ab externa vi excitandus est 12–24 V CC Classis 2 quae directe ad unitatem basalem connectitur. Consumptus currus secundum tensionem variat: fere 340 mA ad 12 V CC et 170 mA ad 24 V CC .

Quaestio 3: Quomodo modum MVI94-MCM configuro?
Responsio 3: Configuratio fit per editionem simplicis textus archivi (.CFG) quocumque textus editori (exempli gratia, Notepad). Archivum in modum per Portus configurationis/debug PRT1 utendo programma emulationis terminalis (p. ex., HyperTerminal) ad 57 600 baud , 8 bit data, 1 bit finis, nulla paritas, nulla comminutio per machinam, et Protocollum transfusionis archivorum Ymodem ad incarcandum vel descarcandum archivum configurationis .

Q4: Quae codices functionum MVI94-MCM sunt admissi?
A4: Cum operatur ut Servus Modbus , the MVI94-MCM accipit codices functionum: 1, 2, 3, 4, 5, 6, 15, et 16 . Cum utitur ut Dominus Modbus , subministratur subsidium pro omnibus octo codicibus functionum supra enumeratis, praeter modus Emittendi (adressem nodi 0) pro iussis scribendi (5, 6, 15, 16).

Quaestio 5: Quomodo MVI94-MCM tractat datos Enron/Daniel in formatu virgulae fluitantis?
A5: MVI94-MCM includit parametra configurationis specialia: Indicativus Virgulae Fluitantis , Initium Virgulae Fluitantis , et Officium Virgulae Fluitantis . Cum Indicativus Virgulae Fluitantis activatur, quaelibet petitio cuius adresa registri maior est quam aut aequalis valori Initii Virgulae Fluitantis tamquam data virgulae fluitantis tractatur. Hoc permittit unam unicam adressem Modbus (p. ex., 47001) ad repraesentandum unum singulum 32‑bit REAL valorem. Pro iussis scribendi ad Enron/Daniel numeros fluitantes, haec functio flagellum Fluitantis requirit esse habilitatum et parametrum Initii Fluitantis recte constitutum.

Interroga nunc: [email protected]

Petite Gratuito Pretium

Noster legatus te brevi continebit.
Epistula Electronica
Nomen
Telephōnum mōbile
Nomen societatis
Nuntius
0/1000

Petite Gratuito Pretium

Noster legatus te brevi continebit.
Epistula Electronica
Nomen
Telephōnum mōbile
Nomen societatis
Nuntius
0/1000