Prosoft

Pagina Prima >  Producta >  ROCKWELL >  Prosoft

PROSOFT ControlLogix MVI56E-MCMXT Modbus Master/Slave Communication Module | In Stock

PROSOFT · CONTROLLOGIX / LOGIX-XT
MVI56E-MCMXT
Modbus Master/Slave Enhanced Communication Module
EXTREME ENVIRONMENT
In stirpe
Originalis novus
Port roles: Two independently configurable Master/Slave ports Interfacies: RS-232 / RS-422 / RS-485
Epistula Electronica: [email protected]
Whatsapp: +86 18159889985

Appurtenance:
  • Conspectus
  • Claves beneficia
  • Portus Rôles
  • Serialis Configuratio
  • Diagnosis
  • Environment
  • Fit Check
  • Requiro Praecipuum
  • FAQ
  • Producta Commendata
PRODUCTUS RÔLE
Serialis Modbus intra ControlLogix

Quid MVI56E-MCMXT facit

Hoc modul connectit Rockwell Automation ControlLogix processores ad Modbus RTU/ASCII disposita. In uno 1756 backplane slotus sedet et Modbus data ad controllerum ut I/O data praebet.

Duos suos serialis applicatio portus independenter configurari possunt, ita ut unus portus ut Modbus Master operari possit dum alter ut Slave, aut ambo eandem functionem in separatis rete perficere possint.

Systema via: ControlLogix processor ↔ backplane I/O ↔ MVI56E-MCMXT ↔ duo rete Modbus serialis

Claves beneficia

Designatus pro migratione et scala
Compatibilitas retrograda
Iter directum substitutionis pro modularibus MVI56 prioribus sine mutatione programmatum controlleris existentis.
10 000 registra
Mappatio definienda ab utente sustinet usque ad 10 000 registra 16-bit.
Designatio unius-slitis
Ingruit in unicum slitem 1756 ControlLogix backplane et sustinet RIUP.

Portus Rôles

Portus configurationis
Rete independens

Unusquisque portus potest constitui ut Magister vel Servus et operari in eadem aut diversa rete Modbus.

Modus Magistri: usque ad 325 praecepta plene configurabilia per portum, cum exploratione optima et observatione status/praeceptorum errorum.

Modus Servilis: adresus nodi 1–247; permittit Magistro remoto legere vel scribere contentum databasis mappatum.

Serialis Configuratio

Adaequare istos valores antequam in servitium ducatur.
Electricum
RS-232 / RS-422 / RS-485
Baud
110 ad 115,2 Kbps
Structura
7 aut 8 bita data; 1 aut 2 bita finis.
Paritas
Nullum / Par / Impar
Portus utuntur conectoribus RJ45 cum adaperationibus RJ45-ad-DB-9M suppeditatis. Handshaking hardware RS-232 configurabile est; quilibet portus serialis per iuncturam eligitur pro RS-232, RS-422 aut RS-485.

Diagnosis

Cito isolatio defectuum.
  • portus Ethernet configurationis 10/100 Base-T RJ45 cum detectione automatica crossover.
  • Display alphanumericum quattuor-characterum volutans ostendit modulum, IP, functionem portus, statum et informationem erroris.
  • Indicationes separatae RX/TX pro quolibet portu seriali, praeter indicationes status ERR, APP et OK.
  • Analyzer rete Modbus incorporatus; codices errorum, numeratores et status portus in memoria dati usoris disponuntur.

Environment

XT HARDWARE
−25 ad 70°C
Ambitus Operationis
Custodia
−40 ad 85°C
Humiditas
5–95 %, non condensans
Vibratio
5 g, 10–150 Hz
Tutela
Custodia conformis pro condicionibus asperis aut causticis

Fit Check

Confirma antequam ordinare
✓ Chassis 1756 ControlLogix / Logix-XT et unum fovea sola disponibilia
✓ MVI56E-MCMXT requiritur pro usu −25 ad 70°C
✓ Functio requisita pro P1 et P2: Magister, Servus, vel mixta
✓ RTU autem ASCII modus et functionum codices
✓ RS-232/422/485 electrica interfacies et connexio
✓ Baud, paritas, data bita, stop bita et nodi adnotationes

Utilia particularia pro citatione: chassis/controller, numerus partis moduli currentis, portarum dispositiones, modello dispositivorum coniunctorum et quantitas quaesita.

Requiro Praecipuum

MVI56E-MCMXT
Petere pretium et disponibilitatem
Epistula Electronica: [email protected]
Whatsapp: +86 18159889985

FAQ

Possuntne utraque porta diversos roles habere?
Ita. P1 et P2 separatim configurari possunt ut Modbus Magister aut Servus, et in eodem aut diversis retibus operari possunt.
Quid MCMXT a MCM distinguit?
Versio XT pro Logix-XT platforma designata est, ab −25 usque ad 70°C operatur, et includit conformal coating pro duris ambientibus.
Quomodo configuratur?
Configuratio in projecto RSLogix 5000 per Add-On Instruction suppeditatum servatur; portus Ethernet configurationem et diagnostics supportat.
Epistula Electronica: [email protected]