Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000

Siemens

Pagina prima>Producta>Siemens

Siemens 6ES7972-0AC80-0XA0 SIMATIC DP RS 485-IS Coupler

Nomen producti: SIMATIC DP RS 485-IS coupler
Nomen Marcae: Siemens
Numerus Modeli: 6ES7972-0AC80-0XA0
Locus Originis: Germania
Garantia: 12 Mensis
Whatsapp: +86 18020776782
Inscriptio electronica: [email protected]
  • Conspectus
  • Commercial Term
  • Specificationes
  • INFORMATIO CONTACTUS
  • DESCRIPTIO
  • Functio
  • De Societate
  • Quaestiones Frequentes
  • Other Products
  • Producta commendata
PROFIBUS DP ad RS 485-IS Fieldbus Coupling

Siemens 6ES7972-0AC80-0XA0 est SIMATIC DP RS 485-IS coupler quod iungit PROFIBUS DP ad intrinsice securum segmentum RS 485-IS pro communicatione cum dispositivis in campo.

Punctum selectionis: Ante installationem, confirmare conceptionem arearum periculosis, documenta segmenti RS 485-IS, ambitum tensionis et currentis, atque instructiones producti Siemens.

Commercial Term

Praeoffertio Solutio Tempus praecedens Navigatio Garantia
Pretium praesens et disponibilitas T/T aut condicionibus conventis Confirmed with the quotation DHL, FedEx, UPS aut oneribus conventis 12 Mensis

Specificationes

Parameter Technicus Valor
Designatio generis producti SIMATIC DP RS 485-IS coupler
Numerus Articuli 6ES7972-0AC80-0XA0
Functiones fieldbus PROFIBUS DP ad RS 485-IS coupler
Applicatio Controllo nodorum PROFIBUS intrinsice securorum
Area installationis Zona Periculosa 2
AMPLITUDO ADMISSIBILIS FONDIS 20,4 ad 28,8 V DC
Maxima Consumptio Electrica 150 mA
Perditio potentiæ typica 3 W
Connexio Alimentationis Blocculus terminalem screw
Gradus praesidium IP20
Ciclus Vitae Producti PM300 Productum Activum
Fabricator Siemens

INFORMATIO CONTACTUS

DESCRIPTIO

6ES7972-0AC80-0XA0 est fieldbus coupler inter PROFIBUS DP et RS 485-IS. Siemens eum specificat ad controllo nodorum PROFIBUS intrinsice securorum, cum installatione coupleris in Zona Periculosa 2 et subsidio latioris ambitus temperaturarum.

Apparatus IP20 utitur connexionem ad alimentum per tornillos et accipit tensionem directam inter 20,4 et 28,8 V. 6ES7972-0AC80-0XA0 opus technicum super [blank] debet sequi praesentes instructiones producti Siemens et designatum systema protectionis contra explosiones pro tota installatione.

Functio

01
Coniunctio bus
Coniungit segmentum PROFIBUS DP normale ad RS 485-IS.
02
Communicatio cum apparatibus in campo
Servit nodis PROFIBUS intrinsece securis in parte RS 485-IS.
03
Installatio in Zona 2
Installa coniunctorem intra condiciones areae periculosae quae sunt documentatae.
04
Integratio in armario
Utere custodia IP20 et connexionem ad alimentum per tornillos in idoneo armario.

De Societate

Supplyplcs supports exact-model review, product-condition confirmation, and responsive industrial automation sourcing.
Share the complete order number, installed-system context, and destination. Our team will coordinate availability, shipment options, and available product documentation.

Quaestiones Frequentes

Q1
When is 6ES7972-0AC80-0XA0 appropriate for a PROFIBUS installation with intrinsically safe field devices?
Use it when the engineered network requires a coupler between PROFIBUS DP and an RS 485-IS fieldbus segment. The hazardous-area design and the connected node approvals must still match the current Siemens instructions for the complete installation.
Q2
Why can the PROFIBUS DP side of 6ES7972-0AC80-0XA0 be active while RS 485-IS field devices do not communicate?
Treat the two bus sides as separate diagnostic paths. Check the documented RS 485-IS wiring, termination, node addresses and supply condition, and stop commissioning if the installed arrangement differs from the approved system design.
Q3
What should I verify before powering 6ES7972-0AC80-0XA0 after cabinet work?
Confirm that the supply remains within 20.4 to 28.8 V DC and that the screw-terminal wiring matches the Siemens product instructions. The enclosure and hazardous-area measures must also be restored before power is applied.
Q4
Quomodo respondeam, si 6ES7972-0AC80-0XA0 amittit communicationem cum temperatus installationis mutatur?
Compara veram temperaturam cistae et stabilitatem subministrationis cum conditionibus operationis documentatis antequam accuplator substituatur. Etiam comportamentum intermittens bus requirit inspectionem connexionum RS 485-IS secundum approbatam proceduram maintenance.
Q5
Num gradus IP20 6ES7972-0AC80-0XA0 permittit eum montare sine cista protectiva?
Non. Gradus IP20 non praebet protectionem pro installatione industriali vel in area periculosa exposita; igitur accuplator integrandus est in cistam et conceptum protectionis definitum per documenta projectus.
Q6
Quae documenta suppeditanda sunt, dum 6ES7972-0AC80-0XA0 adsumitur pro planta iam existente?
Suppedita numerus ordinis completus, versio producti, topologia PROFIBUS DP, elenchus nodorum RS 485-IS, particularia subministrationis et documenta areae periculosae. Haec informatio adiuvat ut exactus rolus accuplatoris confirmetur, sine substitutione repetitoris RS485 normalis.

Other Products

XF830A SDI-OE-S NA200T IZMX-RP16A-200
LFI520 4100LR12 SC200-00
SCD2200-RTU PS-22 IC200MDD844F IC200MDL650L
ABB 1SDH001000R0505-B0821 BS6151 01 SP01 ZBRN2
FGR-002 AMAX-2241 8530D-I
THS710 105S-1 SC42-EP08
AMAX-2241/PMA ADAP-KOOL eWONx005CD
CH-LMD1 SP-0108-H2 ABB 2CDG110137R0011
IMD-IM20 / IM20DEMO Abb 3BSE038226R1 SWH-4200
ABE7 P16T334 81672-01 LP/ 557-180-203

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000