Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6es7972 0ac80 0xa0 simatic dp rs 485 is coupler-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6ES7972-0AC80-0XA0 SIMATIC DP RS 485-IS Coupler

Product Name: SIMATIC DP RS 485-IS Coupler
Brand Name: Siemens
Model Number: 6ES7972-0AC80-0XA0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
  • Overview
  • Commercial Term
  • Specifications
  • Contact info
  • Description
  • Function
  • About Company
  • FAQ
  • Other Products
  • Recommended Products
PROFIBUS DP to RS 485-IS Fieldbus Coupling

Siemens 6ES7972-0AC80-0XA0 is a SIMATIC DP RS 485-IS coupler that links PROFIBUS DP to an intrinsically safe RS 485-IS segment for field-device communication.

Selection checkpoint: Confirm the hazardous-area design, RS 485-IS segment documentation, supply range and current Siemens product instructions before installation.

Commercial Term

QUOTATION PAYMENT LEAD TIME SHIPPING WARRANTY
Current price and availability T/T or agreed terms Confirmed with the quotation DHL, FedEx, UPS or agreed freight 12 months

Specifications

Technical parameter Value
Product type designation SIMATIC DP RS 485-IS coupler
Article number 6ES7972-0AC80-0XA0
Fieldbus function PROFIBUS DP to RS 485-IS coupler
Application Control of intrinsically safe PROFIBUS nodes
Installation area Hazardous Zone 2
Permissible supply range 20.4 to 28.8 V DC
Maximum current consumption 150 mA
Typical power loss 3 W
Supply connection Screw terminal block
Degree of protection IP20
Product lifecycle PM300 Active Product
Manufacturer Siemens

Contact info

Description

6ES7972-0AC80-0XA0 is the fieldbus coupler between PROFIBUS DP and RS 485-IS. Siemens specifies it for controlling intrinsically safe PROFIBUS nodes, with installation of the coupler in hazardous Zone 2 and support for an extended temperature range.

The IP20 device uses a screw-terminal supply connection and accepts 20.4 to 28.8 V DC. Engineering work on 6ES7972-0AC80-0XA0 must follow the current Siemens product instructions and the approved explosion-protection design for the complete installation.

Function

01
Bus coupling
Link a standard PROFIBUS DP segment to RS 485-IS.
02
Field-device communication
Serve intrinsically safe PROFIBUS nodes on the RS 485-IS side.
03
Zone 2 installation
Install the coupler within the documented hazardous-area conditions.
04
Cabinet integration
Use the IP20 housing and screw-terminal supply in a suitable enclosure.

About Company

SupplyPLCs supports exact-model review, product-condition confirmation and responsive industrial automation sourcing.
Share the complete order number, installed-system context and destination. Our team will coordinate availability, shipment options and available product documentation.

FAQ

Q1
When is 6ES7972-0AC80-0XA0 appropriate for a PROFIBUS installation with intrinsically safe field devices?
Use it when the engineered network requires a coupler between PROFIBUS DP and an RS 485-IS fieldbus segment. The hazardous-area design and the connected node approvals must still match the current Siemens instructions for the complete installation.
Q2
Why can the PROFIBUS DP side of 6ES7972-0AC80-0XA0 be active while RS 485-IS field devices do not communicate?
Treat the two bus sides as separate diagnostic paths. Check the documented RS 485-IS wiring, termination, node addresses and supply condition, and stop commissioning if the installed arrangement differs from the approved system design.
Q3
What should I verify before powering 6ES7972-0AC80-0XA0 after cabinet work?
Confirm that the supply remains within 20.4 to 28.8 V DC and that the screw-terminal wiring matches the Siemens product instructions. The enclosure and hazardous-area measures must also be restored before power is applied.
Q4
How should I respond if 6ES7972-0AC80-0XA0 loses communication when the installation temperature changes?
Compare the actual enclosure temperature and supply stability with the documented operating conditions before replacing the coupler. Intermittent bus behavior also requires inspection of the RS 485-IS connections under the approved maintenance procedure.
Q5
Does the IP20 rating of 6ES7972-0AC80-0XA0 allow it to be mounted without a protective enclosure?
No. IP20 does not provide protection for an exposed industrial or hazardous-area installation, so the coupler must be integrated into the enclosure and protection concept defined by the project documentation.
Q6
Which records should be supplied when sourcing 6ES7972-0AC80-0XA0 for an existing plant?
Provide the complete order number, product version, PROFIBUS DP topology, RS 485-IS node list, supply details and hazardous-area documentation. This information helps confirm the exact coupler role without substituting a standard RS485 repeater.

Other Products

XF830A SDI-OE-S NA200T IZMX-RP16A-200
LFI520 4100LR12 SC200-00
SCD2200-RTU PS-22 IC200MDD844F IC200MDL650L
ABB 1SDH001000R0505-B0821 BS6151 01 SP01 ZBRN2
FGR-002 AMAX-2241 8530D-I
THS710 105S-1 SC42-EP08
AMAX-2241/PMA ADAP-KOOL eWONx005CD
CH-LMD1 SP-0108-H2 ABB 2CDG110137R0011
IMD-IM20 / IM20DEMO Abb 3BSE038226R1 SWH-4200
ABE7 P16T334 81672-01 LP/ 557-180-203

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000