| VENDITE | Epistula electronica | Telephus WhatsApp |
|---|---|---|
| Iimus Pei | [email protected] | +86 18020776782 |
| Modellum | 3601E |
| Genus moduli | Output digitalis TMR |
| Puncta Exirentia | 16 |
| Communio output | Non-communis |
| Isolatio Externi | Optice isolata |
| Nominal Output Voltage | 115 V AC |
| Operans voltage range | 80 ad 155 V AC |
| Operating Frequency | 47 ad 63 Hz |
| Decrementum voltatis exsurgentis | Minus quam 3 V typice |
| Maxima Currentis Onus | 2 A per punctum |
| Assurgat current | 12 A pro uno cyclo AC |
| Current fuga oneris | 2 mA maximum ad 60 Hz |
| Currentus fuga chassidis | 4 mA maximum ad 60 Hz |
| Fusibilis campi | 3 A actionis celeris per outputum |
| Isolatio Puncti | 1500 V DC |
| Indicatio Status Output | Unus indicativus pro singulo puncto |
| Indicatores status moduli | PASS, FAULT et ACTIVE |
| Indicatio oneris/fusibilis | Praebitum |
| Module Color Code | Viridis |
| Output Architecture | Via controlis triplicata |
| Typus terminationis compatibilis | 16-puncta non-communia DO tabellae |
| Dimensiones | 2.2 × 40.8 × 39.8 cm |
| Pondus | Circiter 2.84 kg |
| Minimum quantitas ordinis | 1 piece |
| Pretium | Contactus pro Jim |
| Singula Packaging | Novus Originalis, Sigillatus a Fabrica |
| Tempus Traditionis | 3–7 dies |
| Condiciones solutionis | T/T |
| Shipping modum | DHL / FedEx / UPS / TNT |
| Capacitas Supplicandi | Novus prorsus, in stock |
3601E est Triconex Tricon triplex-modularis-redundans digitalis outputus modulare cum sedecim non-communis, optice isolatis 115 V AC punctis. Outputus operantur inter 80 et 155 V AC ad 47–63 Hz et possunt erogare usque ad 2 A per punctum. Singulae circuitus campi utuntur propria 3 A fusibili cito-actuante in terminationis confectione.
Modulare accipit triplicatam decisionem de interrumpendo a Tricon chassio et movet independentes AC oneras per canales outputus isolatos. Indicatores per punctum ostendunt conditionem outputus praeceptae, dum indicatores PASS, FAULT et ACTIVE referunt statum moduli. Indicatio onerae/fusibilis iuvat personalem manutentionis invenire apertam viam protectionis campi.
A replacement must retain the non-commoned wiring arrangement and the correct 115 V AC termination panel. Field fuse ratings, isolation barriers and channel conductors should be checked before energization. The installed logic should be reviewed so each of the sixteen output points returns to its intended safe state.
| RF5108WKK1-433 | LV-125 | D8RW2 |
| S-3-TCPUSE-H-Di6 | CES-A-UEA-04B | PS00E03knx |
| VICTOR 0781-3619 | DALIKNX2CH | NC3MD-LX |
| MDR-20-5 | MTL-FS32 | IE-SW-BL05-5TX |
| DIN-8SW8-I 6503776 | MOV-175 | IPSI-2 |
| T15HD 60-345-02 | RFC-215 | TF223AD/U |
| FP0-C16T FP0-E8RS | MF6FTJ0026 | EB401-10 |
| QSNE-4A-D | X-15s X-600M X-400 | SEC-TEA-230-5045 |
| LS3408-ER20155R | ET901-AC | CLIOP823A |
| MP-6000 | C2ENET-1 C2 ENET-1 | XYTRONIX X-15s |
| b3600 B3624-A | R9801026 KVD5521 | DMC-C 6504086 |
| VT7820 | HL8102K | MMS-A-350 |
| PTXE6A-M | PG4 S-M10 | HL8102B |