| Model | 3601E |
| Module type | TMR digital output |
| Output points | 16 |
| Output commoning | Non-commoned |
| Output isolation | Opto-isolated |
| Nominal output voltage | 115 V AC |
| Operating voltage range | 80 to 155 V AC |
| Operating frequency | 47 to 63 Hz |
| Output voltage drop | Less than 3 V typical |
| Maximum load current | 2 A per point |
| Surge current | 12 A for one AC cycle |
| Load leakage current | 2 mA maximum at 60 Hz |
| Chassis leakage current | 4 mA maximum at 60 Hz |
| Field fuse | 3 A fast-acting per output |
| Point isolation | 1500 V DC |
| Output status indication | One indicator per point |
| Module status indicators | PASS, FAULT and ACTIVE |
| Load/fuse indication | Provided |
| Module color code | Green |
| Output architecture | Triplicated control path |
| Compatible termination type | 16-point non-commoned DO panels |
| Dimensions | 2.2 × 40.8 × 39.8 cm |
| Weight | Approx. 2.84 kg |
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
3601E is a Triconex Tricon triple-modular-redundant digital output module with sixteen non-commoned, optically isolated 115 V AC points. The outputs operate across 80 to 155 V AC at 47 to 63 Hz and can deliver up to 2 A per point. Each field circuit uses its own 3 A fast-acting fuse at the termination assembly.
The module receives the triplicated control decision from the Tricon chassis and drives independent AC loads through isolated output channels. Per-point indicators show commanded output condition, while PASS, FAULT and ACTIVE indicators report module status. Load/fuse indication helps maintenance personnel locate an open field protection path.
A replacement must retain the non-commoned wiring arrangement and the correct 115 V AC termination panel. Field fuse ratings, isolation barriers and channel conductors should be checked before energization. The installed logic should be reviewed so each of the sixteen output points returns to its intended safe state.
| RF5108WKK1-433 | LV-125 | D8RW2 |
| S-3-TCPUSE-H-Di6 | CES-A-UEA-04B | PS00E03knx |
| VICTOR 0781-3619 | Daliknx2Ch | NC3MD-LX |
| MDR-20-5 | MTL-FS32 | IE-SW-BL05-5TX |
| DIN-8SW8-I 6503776 | MOV-175 | IPSI-2 |
| T15HD 60-345-02 | RFC-215 | TF223AD/U |
| FP0-C16T FP0-E8RS | MF6FTJ0026 | EB401-10 |
| QSNE-4A-D | X-15s X-600M X-400 | SEC-TEA-230-5045 |
| LS3408-ER20155R | ET901-AC | CLIOP823A |
| MP-6000 | C2ENET-1 C2 ENET-1 | XYTRONIX X-15s |
| b3600 B3624-A | R9801026 KVD5521 | DMC-C 6504086 |
| VT7820 | HL8102K | MMS-A-350 |
| PTXE6A-M | PG4 S-M10 | HL8102B |