Nomen producti: Modulus Processus Principalis (MP)
Nomen marcae: Triconex Invensys
Numerus exemplaris: MP3101 MP 3101
Locus originis: USA
Warranty: 12 menses
Whatsapp:+86 18020776782
Epistula electronica: [email protected]
Sales |
Electronicum |
Telephus WhatsApp |
Iimus Pei |
| Nomen Producti | Triconex Invensys MP3101 MP 3101 Main Processor Module (MP) |
| Fabricator | Triconex Invensys |
| Product Type | Modulus Processus Principalis (MP) |
| Numerus partis | MP3101 MP 3101 |
| Pondus | 1.66 kg |
| Dimensiōnēs nāvīgātiōnis aestimātae | 4.3x18.8x21.8 cm |
| Locus navandi | Xiamen, Sinae |
| Patria Origin | USA |
| Processus Applicationis | Motorola MPC860, 32-bit, 50 MHz |
| Flash PROM | 6 MB, CRC-Protectum |
| DRAM Processus Applicationis | 16 MB, Paritas Octetorum |
| NVRAM | 8 KB, CRC-Protectum |
| Functionis NVRAM | Variabiles Retentivae |
| Processus IOX | Motorola MPC860, 32-bit, 50 MHz |
| IOX DRAM | 16 MB, Paritas Octetorum |
| Memoria Communis | 128 KB, Byte Parity |
| Velocitās TriBus | 25 Mbps |
| Bus Communīcātiōnis | RS-485, 2 Mbps HDLC |
| I/O Bus | RS-485, 2 Mbps HDLC |
| Diagnostic Bus | 2 Mbps HDLC |
| TriStation Port | 1 × 10BaseT Ethernet |
| TriStation Connector | RJ-45, Schirmat, sur Plaque de Base |
| Port Modbus | 1 × RS-232/485 DTE |
| Connecteur Modbus | DB-9, Schirmat, sur Plaque de Base |
| Port de Débogage | RJ-12 |
| Contactus allarmi | Redondant, Normalement Fermé |
| Tensio Input Nominale | 24 VDC |
| Plage de Tension de Fonctionnement | +19,2 à +30 VCC |
| Potentia Logica | 8 W Maximum |
| Voltage Input Maximum Absolutum | 33 VDC |
| Absolute Maximum Reverse Input Voltage | -0.6 VDC |
| Inrush Current per Input | 2.4 A Maximum; 1.2 A for 50 ms Typical |
| Short-Circuit Current Limit per Input | 2.4 A Maximum |
| Protective-to-Functional-Earth Isolation | 500 VDC |
| Altilium | ½ AA Lithium |
| Battery Predicted Life | 15 Annos |
| Modbus RS-232 Maxima Longitudo Cavi | 15 m (50 ft) |
| Modbus RS-485 Maxima Longitudo Cavi | 1.2 km (4 000 ft) |
| Modbus Velocitates Transmissionis | 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K bps |
| Protocolum Modbus | Servus, Modus RTU, Paritas Optativa, 1 Bitus Finis |
| Network Port | 10BaseT Ethernet |
| Maxima Longitudo Cavi Retei | 100 m (330 ft), Categoria 5 Paria Torsa |
| Protocolla Network | TriStation, TSAA, Triconex Peer-to-Peer |
| Front Panel Status Indicators | PASS, FAULT, ACTIVE |
|
Minimum quantitas ordinis |
1 piece |
|
Pretium |
Contactus pro Jim |
|
Singula Packaging |
Originales nova Officina Sigillata |
|
Tempus Traditionis |
3–7 dies |
|
Condiciones solutionis |
T/T |
|
Shipping modum |
DHL / FedEx / UPS / TNT |
|
Capacitas Supplicandi |
In stirpe |
The Triconex Invensys MP3101 MP 3101 is a Main Processor Module designed for high-integrity Triconex control and safety system applications. It incorporates dedicated 32-bit Motorola MPC860 application and I/O processors, protected memory resources, and a high-speed 25 Mbps TriBus for reliable system processing and data exchange. The module supports TriStation Ethernet, Modbus RS-232/485, TSAA, and Triconex peer-to-peer communications, providing flexible connectivity for engineering, monitoring, and external system integration. With retentive memory, redundant alarm contacts, extensive diagnostics, and industrial power protection, it is well suited for safety instrumented systems, emergency shutdown, process protection, and other mission-critical industrial control applications.
Q1: What role does the Triconex Invensys MP3101 MP 3101 play in a control system?
The MP3101 MP 3101 functions as the main processor module, handling application processing, I/O coordination, system communication, and diagnostic activities within compatible Triconex control and safety systems.
Q2: How does the MP3101 protect critical program and operating data?
It uses CRC-protected Flash PROM and NVRAM together with parity-protected DRAM to help maintain the integrity of application programs, retentive variables, and operational data.
Q3: What communication options are available for connecting the MP3101 to other equipment?
The MP3101 provides 10BaseT Ethernet and RS-232/485 connectivity, supporting TriStation, TSAA, Triconex peer-to-peer, and Modbus communications.
Q4: How does the MP3101 handle communication with system I/O?
It uses dedicated I/O processing resources and an RS-485 HDLC I/O bus to coordinate data exchange between the processor and compatible I/O components.
Q6: What is the purpose of the TriBus in the MP3101 system architecture?
The MP3101 MP 3101 uses a 25 Mbps TriBus for high-speed internal communication and coordinated data exchange within the compatible Triconex system.
Q7: How can operators identify the operating condition of the MP3101?
PASS, FAULT, and ACTIVE indicators on the front panel provide convenient visual information about module health and operating status.
ABB: partes robotorum industrialium seriei DSQC, Bailey INFI90, DCS
Honeywell: 51/MU/MC/TC/CC ...
Triconex: 3008/3511/3625/3664/3721/3700A..
Bently Nevada: 3500/3300/330180-Cable..
Foxboro: FBM203/204/217/231, FCP240/270
Woodward: SPC valve position controller, PEAK15 digital controller
Siemens: 6DD/6DP/6ES5/6DR/6GK Series
Westinghouse Series: 1C/5X ...
General Electric: IC693/IC697/IC695/DS200..
Schneider: 140 Series
☑ Millia supplicantium et ampla varietas productorum tibi permittunt experientiam unius emporii.
☑ Productum summae qualitatis.
☑ Plurima producta habent periodum garantis usque ad annum unum; si qua problemata qualitatis oriantur, pecunia refundetur a nobis. Quisque res antequam mittatur rigide probatur.
☑ Personale nostrum venditionis tibi praebet plus quam decem horas servitii et cito respondet quaestionibus tuis.
☑ Omnia producta cito mittuntur intra unum ad tres dies post ordinem datum. Plurima merces ad te tempore idoneo per velocissimum servitium DHL deludentur.
☑ Bonus embalatio tutitudinem transportis assicurat et magnopere minuit pretium transportis.