WOODWARD Power Supply to Main Chassis 5501-380 Original new

Nomen producti: Power Supply to Main Chassis

Nomen Marcae: WOODWARD

Numerus Modeli: 5501-380

Terra Originis: USA

Warranty: 12 Mensis

Whatsapp:+86 18159889985

E-mail:[email protected]

Appurtenance:
  • Praevisio
  • Contactus pro citatione
  • Especificaciones
  • DESCRITIO
  • Praeceptum competitivum
  • Caracteristici
  • THEORIA OPERATIONIS
  • PARTES SUPPLEMENTARIAE
  • Prodòtti raccomandàti

Praevisio

Nomen Marcae:

WOODWARD

Numerus Modeli:

5501-380

Terra Originis:

USA

Particularia Impressionis:

Novus Originalis, Sigillatus a Fabrica

Tempus Distributionis:

Tempus expeditionis, si in deposito

Conditiones Pecuniarum:

T/T

Capacitas Suppeditandi:

in stoce

Contactus pro citatione

Praepositus Venalium:

Stella

Mitte epistulam electronicam:

[email protected]

Contactus per Whatsapp:

+86 18159889985

Especificaciones

Parametrus

Specificatio

Fabricator

WOODWARD

Numerus partis

5501-380

Typus Producti

TMR Power Supply Module / Power Supply Board

Compatibilitas Systematis

MicroNet TMR / 5009 Digital Control Series

Tensionem introductam

120 VAC (47–63 Hz) aut 120 VDC

AC Operating Range

88–132 VAC, 47–63 Hz

DC Operating Range

100–150 VDC

Maximum Power (AC)

1150 VA

Maximum Power (DC)

576 W

Maximum DC Current

5,8 A

Tempus retentum

7 ms ad 120 VDC

Output channels

6 independentes regulatas outputs 24 VDC

Tensio Egressus

24 VDC ± 5%

Currentia maxima emissa

32 A totalis

Efficientia

≥ 85%

Tutelam circuitus

AC: 20 A temporis-differens interruptor; DC: 10 A temporis-differens fusibilis

Magnitudo fili (DC)

14 AWG / 2.5 mm²

Magnitudo fili (AC)

12 AWG / 4 mm²

Diodi Electroluminescentes in fronte tabulae

OK (viridis), Defectus suppellectilis electricae (ruber), Super-temperatura (ruber), Defectus intrantis (ruber)

Excessus Caloris Officium

Supra 90°C; resolvitur infra 75°C

Temperatura operationis

–40°C ad +70°C

Dimensiones (L×A×P)

circa 128.25 × 195.15 × 157.09 mm

Gravitas

Circa 1.3 – 2.4 kg (secundum configurationem)

Montatio

Montage in armario (fissurae PA1/PA2 in chasis TMR)

Certificationes

CE, UL, CSA

Patria Origin

USA

Status cyclī vītae

Non ulterius fabricatus ab artifex; adhibibilis per distributores

DESCRITIO

Le Woodward 5501-380 est modululus alimentationis TMR (Triplex Modularis Redundans) alti rendimenti, constructus pro platformis digitalibus MicroNet et 5009 . Hoc 5501-380modululus accipit duplicem ingressum 120 VAC aut 120 VDC et praebet sex independentes regulatas 24 VDC exsitus ad alimentandum CPU, I/O, et modulos communicationis . The 5501-380habet diagnosticos LED in fronte tabulae ad monitorandum statum in tempore reale. Cum latissimo intervallo operationis a –40°C usque ad +70°C et circuitibus protectionis completis, 5501-380ensures uninterrupted operation in mission-critical turbine and engine control applications .

Praeceptum competitivum

  • TMR Triple Modular Redundancy – Supports dual power supply configurations with automatic failover and load sharing; single module failure triggers millisecond-level seamless switchover without system interruption

  • Dual-Format Input Compatibility – Accepts both 120 VAC and 120 VDC, eliminating the need for separate power supply variants for AC and DC plant environments

  • Six Independent Regulated Outputs – Provides 24 VDC across six channels (two @ 12 A, two @ 5 VDC/20 A, two 5 VDC pre-charge) for comprehensive backplane power distribution

  • Comprehensive Hardware Protection – Built-in overvoltage (OVP), overcurrent (OCP), short-circuit, overtemperature (OTP), and input phase-loss protection

  • Capacitas Substitutionis Calidae – Field-replaceable without system shutdown in redundant configurations, minimizing critical downtime

  • Refrigeratio Convectiva Passiva – Design sine ventili eliminat partes mobiles, minuens necessitates maintenance et meliorans fidabilitatem in ambientes pulvereos

Caracteristici

  • Supportus Tensionis Input Dualis – Operat in 120 VAC (47–63 Hz) aut 120 VDC cum latissimis intervallis tolerantiae

  • Sex Exitus DC Regulati – Alimentat totum chassim TMR, incl. CPUs tripliciter redundantes et modulos I/O

  • Architectura Redundans TMR – Duo moduli 5501-380 possunt installari in locis PA1/PA2 cum coordinatione backplane pro alimentatione sine interruptione

  • Diodi LED Status Frontalis – Quattuor indicatores (OK, Defectus Alimentationis, Supertemperatura, Defectus Input) pro diagnosticis rapidis in situ

  • Comprehensivum Protectivum Suite – Protectio pro voltatione excesse, currente excesse, circuitu curtus, temperaturo excesse, et amissione phasium intrantis

  • Refrigeratio passiva sine ventili – Dissipatio caloris per convectionem cum interruptio automatica pro temperatura supra 90°C

  • Praeparatus pro substitutione calida – Subtinet substitutionem moduli in statu activo in configurationibus redundantis

  • Constructio Industrialis – Corporis robusti ex metallo scutati cum immunitate contra interferences electromagneticas pro ambientibus asperis

THEORIA OPERATIONIS

Le 5501-380fungitur ut columna vertebralis distributionis electricae principalis pro systematibus controlis Woodward MicroNet TMR (Redundantia Modularis Triplex) . Post acceptationem potestatis intrantis 120 VAC vel 120 VDC per terminales in facie anteriore, modulus convertit et regulat supplitium in sex outputs 24 VDC independenter regulatos, distributos per dorsalem planum systematis .

In configuratione redundante, duo 5501-380moduli insunt in locis chassii specialibus PA1 (Supples Potestatis #1) et PA2 (Supples Potestatis #2) . A motherboard on the rear of the power supply chassis coordinates the two modules, enabling load sharing under normal conditions and seamless automatic failover should one module fail or be removed . The architecture ensures that the TMR CPU, I/O, and communication modules remain fully energized even during a single power supply fault .

The module incorporates comprehensive protection circuitry: input overvoltage and undervoltage detection, output overcurrent limiting, short-circuit lockout, and overtemperature monitoring . An overtemperature fault triggers shutdown above 90°C, with automatic recovery when temperature falls below 75°C . Front-panel LEDs provide real-time status—green "OK" indicates normal operation, while red LEDs signal input fault, power supply fault, or overtemperature conditions . The fanless passive convection cooling design eliminates moving parts, enhancing long-term reliability in high-vibration and dust-prone industrial environments .

PARTES SUPPLEMENTARIAE

Elementum

DESCRITIO

Numerus partis / Referentia

TMR Power Supply Module

120 VAC/VDC input, 6 x 24 VDC outputs for MicroNet TMR chassis

5501-380

220 VAC Power Supply

Alternative input version for 220 VAC applications

5501-381

24 VDC Input Power Supply

Lower-voltage variant for 24 VDC systems

5501-370

Blanking Panel

Covers unused power supply slot in non-redundant configurations

3799-301

Main Control Chassis

5009FT TMR chassis with redundant power supply backplane

5009FT Series

Modulus CPU

Processus PowerPC 5200 400 MHz pro systemata TMR

5466-1047

Alimentatio kernel

modulus alimentationis kernel 24 VDC

5466-1049

Commutator retei

Interruptor Ethernet industrialis Hirschmann

1752-423

External Power Supply

Alimentatio Phoenix Quint 24 VDC / 5 A