honeywell mc taox12 51304335 175 analog output field termination assembly-0

DCS

Home >  Products >  HONEYWELL >  DCS

HONEYWELL MC-TAOX12 51304335-175 Analog Output Field Termination Assembly

Product Name: Analog Output Field Termination Assembly

Brand Name:  HONEYWELL

Model Number: MC-TAOX12 51304335-175

Place of Origin: USA

Warranty: 12 Months

Whatsapp+86 18020776782

Email[email protected]

  • Overview
  • Contact US
  • Specifications
  • Advantages
  • Features
  • Application Scenarios & Guidelines
  • Technical Notes
  • FAQ
  • Recommended Products

Description

The HONEYWELL MC-TAOX12 51304335-175 is a Analog Output Field Termination Assembly used within Honeywell’s HPM architecture. It provides an efficient connection point for up to 12 analog output channels. The assembly supports redundant operation, ensuring high availability in critical process loops. Designed for integration within the HPM cabinet environment, the HONEYWELL MC-TAOX12 51304335-175 streamlines field wiring installation and maintenance, serving as a robust bridge between the controller IOPs and the plant-floor instrumentation.

Main Function

The HONEYWELL MC-TAOX12 51304335-175 serves as a Field Termination Assembly (FTA) specifically designed for the HPM subsystem. It acts as the physical interface between process control field wiring and the Analog Output Processor (IOP) cards, facilitating the transmission of 4-20 mA control signals to final control elements like actuators and valve positioners while providing terminal points for field signal distribution.

Commercial Terms

Minimum Order Quantity

1 Piece

Price

Contact for Winnie

Packaging Details

Original new Factory Sealed

Delivery Time

3–7 Days

Payment Terms

T/T

Shipping Method

DHL / FedEx / UPS / TNT

Supply Ability

In stock

Contact US

Sales:

Email:

Whatsapp:

JIM

[email protected]

+86 18020776782

Specifications

Manufacturer

HONEYWELL

Product Type

Analog Output Field Termination Assembly

Part Number

MC-TAOX12 51304335-175

Operating Voltage

24 Vdc (System Power)

Signal Range

4-20 mA (Output)

Channel Density

12 Channels

Operating Temperature

0°C to +60°C (32°F to 140°F)

Storage Temperature

-40°C to +70°C (-40°F to 158°F)

Relative Humidity

5% to 95% (Non-condensing)

Compatibility

Designed for Honeywell HPM/TPS subsystem I/O integration

Estimated shipping dimensions

12x8.5x30.7cm

Weight

0.48kg

Place of shipment

Xiamen, China

Advantages

Redundancy Support: The HONEYWELL MC-TAOX12 51304335-175 is engineered for redundant IOP configurations to maintain process continuity.

Simplified Wiring: High-density terminal arrangements reduce cabinet space requirements and installation time.

Process Integrity: Standardized signal termination minimizes signal interference and transmission errors in industrial environments.

Features

12-Channel I/O Support: Accommodates up to 12 individual analog output loops on a single assembly.

Direct Field Termination: Provides direct screw-terminal connections for field cables, eliminating intermediate junction blocks.

HPM Integration: Fully compatible with Honeywell High-Performance Process Manager (HPM) subsystem protocols.

Redundancy Capability: Facilitates seamless switchover in redundant controller IOP deployments.

Application Scenarios & Guidelines

Application Scenarios: Used in critical continuous process control, including oil & gas refining, chemical manufacturing, and power generation. Essential for modulating control loops requiring precise actuator positioning.

Monitoring & Control: Supports loop-level monitoring through the HPM controller. Provides physical test points for signal validation during loop checks.

Compatibility & Interoperability: Directly interfaces with Honeywell HPM Analog Output IOPs via specialized I/O cables. Interoperable with standard industry 4-20 mA control elements.

Certifications & Standards: Manufactured to meet Honeywell TPS/HPM system quality standards. Designed for installation in standard industrial control cabinets complying with IEC site planning guidelines.

Technical Notes

The HONEYWELL MC-TAOX12 51304335-175 requires verification of IOP revision compatibility before installation in legacy HPM systems. Always ensure the physical grounding bar is properly bonded to the cabinet ground to maintain signal integrity for the HONEYWELL MC-TAOX12 51304335-175.

FAQ

Q: Can the HONEYWELL MC-TAOX12 51304335-175 be used in a non-redundant configuration?

A: Yes, the HONEYWELL MC-TAOX12 51304335-175 is versatile and can be configured for either redundant or non-redundant I/O operations depending on the HPM IOP setup.

Q: What is the primary diagnostic capability of the HONEYWELL MC-TAOX12 51304335-175?

A: While the HONEYWELL MC-TAOX12 51304335-175 is a passive termination assembly, diagnostics are performed at the IOP level; the FTA provides the necessary physical test points to verify signal continuity for each channel.

Q: Is the HONEYWELL MC-TAOX12 51304335-175 compatible with older TDC 3000 systems?

A: The HONEYWELL MC-TAOX12 51304335-175 is intended for the High-Performance Process Manager (HPM) subsystem; integration with older TDC 3000 components requires confirming specific HPM release compatibility documented in the HPM Planning Manual.

Q: How should I address signal faults identified at the HONEYWELL MC-TAOX12 51304335-175?

A: In the event of a signal fault, check the field wire termination at the HONEYWELL MC-TAOX12 51304335-175 and compare findings against the loop diagram to ensure no open circuits or short-to-ground conditions exist in the field wiring.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000