Product Name: Analog Output Field Termination Assembly
Brand Name: HONEYWELL
Model Number: MC-TAOX12 51304335-175
Place of Origin: USA
Warranty: 12 Months
Whatsapp:+86 18020776782
Email:[email protected]
Description
The HONEYWELL MC-TAOX12 51304335-175 is a Analog Output Field Termination Assembly used within Honeywell’s HPM architecture. It provides an efficient connection point for up to 12 analog output channels. The assembly supports redundant operation, ensuring high availability in critical process loops. Designed for integration within the HPM cabinet environment, the HONEYWELL MC-TAOX12 51304335-175 streamlines field wiring installation and maintenance, serving as a robust bridge between the controller IOPs and the plant-floor instrumentation.
Main Function
The HONEYWELL MC-TAOX12 51304335-175 serves as a Field Termination Assembly (FTA) specifically designed for the HPM subsystem. It acts as the physical interface between process control field wiring and the Analog Output Processor (IOP) cards, facilitating the transmission of 4-20 mA control signals to final control elements like actuators and valve positioners while providing terminal points for field signal distribution.
Commercial Terms
Minimum Order Quantity |
1 Piece |
Price |
Contact for Winnie |
Packaging Details |
Original new Factory Sealed |
Delivery Time |
3–7 Days |
Payment Terms |
T/T |
Shipping Method |
DHL / FedEx / UPS / TNT |
Supply Ability |
In stock |
|
Sales: |
Email: |
Whatsapp: |
|
JIM |
|
Manufacturer |
HONEYWELL |
|
Product Type |
Analog Output Field Termination Assembly |
|
Part Number |
MC-TAOX12 51304335-175 |
|
Operating Voltage |
24 Vdc (System Power) |
|
Signal Range |
4-20 mA (Output) |
|
Channel Density |
12 Channels |
|
Operating Temperature |
0°C to +60°C (32°F to 140°F) |
|
Storage Temperature |
-40°C to +70°C (-40°F to 158°F) |
|
Relative Humidity |
5% to 95% (Non-condensing) |
|
Compatibility |
Designed for Honeywell HPM/TPS subsystem I/O integration |
|
Estimated shipping dimensions |
12x8.5x30.7cm |
|
Weight |
0.48kg |
|
Place of shipment |
Xiamen, China |
Redundancy Support: The HONEYWELL MC-TAOX12 51304335-175 is engineered for redundant IOP configurations to maintain process continuity.
Simplified Wiring: High-density terminal arrangements reduce cabinet space requirements and installation time.
Process Integrity: Standardized signal termination minimizes signal interference and transmission errors in industrial environments.
12-Channel I/O Support: Accommodates up to 12 individual analog output loops on a single assembly.
Direct Field Termination: Provides direct screw-terminal connections for field cables, eliminating intermediate junction blocks.
HPM Integration: Fully compatible with Honeywell High-Performance Process Manager (HPM) subsystem protocols.
Redundancy Capability: Facilitates seamless switchover in redundant controller IOP deployments.
Application Scenarios: Used in critical continuous process control, including oil & gas refining, chemical manufacturing, and power generation. Essential for modulating control loops requiring precise actuator positioning.
Monitoring & Control: Supports loop-level monitoring through the HPM controller. Provides physical test points for signal validation during loop checks.
Compatibility & Interoperability: Directly interfaces with Honeywell HPM Analog Output IOPs via specialized I/O cables. Interoperable with standard industry 4-20 mA control elements.
Certifications & Standards: Manufactured to meet Honeywell TPS/HPM system quality standards. Designed for installation in standard industrial control cabinets complying with IEC site planning guidelines.
The HONEYWELL MC-TAOX12 51304335-175 requires verification of IOP revision compatibility before installation in legacy HPM systems. Always ensure the physical grounding bar is properly bonded to the cabinet ground to maintain signal integrity for the HONEYWELL MC-TAOX12 51304335-175.
Q: Can the HONEYWELL MC-TAOX12 51304335-175 be used in a non-redundant configuration?
A: Yes, the HONEYWELL MC-TAOX12 51304335-175 is versatile and can be configured for either redundant or non-redundant I/O operations depending on the HPM IOP setup.
Q: What is the primary diagnostic capability of the HONEYWELL MC-TAOX12 51304335-175?
A: While the HONEYWELL MC-TAOX12 51304335-175 is a passive termination assembly, diagnostics are performed at the IOP level; the FTA provides the necessary physical test points to verify signal continuity for each channel.
Q: Is the HONEYWELL MC-TAOX12 51304335-175 compatible with older TDC 3000 systems?
A: The HONEYWELL MC-TAOX12 51304335-175 is intended for the High-Performance Process Manager (HPM) subsystem; integration with older TDC 3000 components requires confirming specific HPM release compatibility documented in the HPM Planning Manual.
Q: How should I address signal faults identified at the HONEYWELL MC-TAOX12 51304335-175?
A: In the event of a signal fault, check the field wire termination at the HONEYWELL MC-TAOX12 51304335-175 and compare findings against the loop diagram to ensure no open circuits or short-to-ground conditions exist in the field wiring.