Magaca Alaabta: PROFIBUS DPV1 Maaster
Magaca Brand: Prosoft
Lambarka Modelka: PS69-DPM
Dalka kaleyska: Dhalinyarada Amerikanka
Damaanad: boqortooyada 12 Bulsho
Whatsapp: +86 18159889985
Iimaylka: [email protected]
Magaca Brand: |
Prosoft |
Lambarka Modelka: |
PS69-DPM |
Dalka kaleyska: |
Dhalinyarada Amerikanka |
Furaha Talaalada: |
Cusub oo ah orijinaalka, oo ku dhaqmayn khasabta ah |
Wakhtiga aad ugu yaraysid: |
Wakhtiga soo guurinta marka la jirto magaalo |
Shurtida Casirada: |
T/T |
|
Mudirka Biyaha: |
Stella |
|
Ii email: |
|
|
Xiriirka WhatsApp: |
Waxaa PS69-DPM waa moduulka ugu horreysa ee PROFIBUS DPV1 oo ku dhisnayso si guul leh xiriirka PROFIBUS ee CompactLogix ama MicroLogix 1500 kontrolisinta . Wuxuu ka caawisaa heerka I/O iyo fariin CIP, wuxuuna PS69-DPM ku dhisnayso shakhsiyaalaha DPV0 iyo DPV1 ee ku jira qaybta kala duwan ee 1769 ee la xiriiraan karaa . Xiriirka iyo tijaabinta waxa lagu sameeyaa saddexda PROSOFT.fdt (SYCON.net), taasoo ugu yaraa fikradaha la xiriiraan karaa PS69-DPM waxaana ugu yaraa fikradaha la xiriiraan karaa oo ku saabsanaya heerka sare ee xiriirka PROFIBUS ee la isticmaalo qoyska industriyada
Xiriirka Kala Duwan ee Fabriga – Ku xidhiidh sensarada, aktewaradaha, iyo dreywadaha kuwa ka shaqaynayaan koontraladaha CompactLogix/MicroLogix iyadoo la isticmaalayo PROFIBUS DP
Nidaamka Kontrolka Qaarka – Ku xidhiidh qorshaha iyo analaayzadaha PROFIBUS kuwa ka shaqaynayaan nidaamka Rockwell Automation
Isku daynta & Guurka – Badalka qorshaha hore ee RIF 1769-DPM bilaawayaasha isku daynta ah, la isku dayn karin koodka ladder ama xasiloonka ah
Ku xidhiidhka Qorshaha Ka Mid Ah – Ku xidhiidh koontraladaha Rockwell iyo qorshaha PROFIBUS ka mid ah Siemens, ABB, iyo maamulaha kale
Nidaamka I/O Ka Dib Ugu Jira – Dhismaha nidaamka koor-ka dib ugu jira oo la isticmaalo qorshaha ka mid ah 125 oo ka mid ah qorshaha ka dib ugu jira ee kuwa ka mid ah qaybaha badan
Koor-ka Warshadaha – Isticmaalaya xasilloo ku saabsan FDT/DTM si loo isticmaalo dhammaan waxyaabaha la xiriira karaa iyo ku daro xaaladda qorshaha
Wax ka mid ah qaybta ee leh gudaha 1769-ka
PROFIBUS DPV1 Master oo leh taageerada guud ee seerviisada DPV0 iyo DPV1
Wax uga wadi karaa in lagu isticmaalo PROFIBUS slave devices 125 ka badan, kuwaas oo ku yaal 32 qaybta PROFIBUS-ka per bus segment, oo wax uga wadi karaa iyadoo isticmaasho repeaters
PROFIBUS certified, UL 508, C-UL iyo CE certified
Rogashada PROSOFT.fdt (SYCON.net) oo ku saabsan FDT ayaa ku daro
Wax uga wadi karaa RIF 1769-DPM project conversion compatibility si loo beddelo qaybta hore
Tusmaha ladder logic files iyo Add-On Instruction (AOI) ayaa ku daro RSLogix 5000 (V16 ama sare)
Qaybta diyaagnoostik ee serial ee si loo isticmaalo ku daro xaaladda heerka iyo si loo tijaabo qaybta
Wax uga wadi karaa CIP messaging si loo isticmaalo data exchange acyclic ee platformada la isticmaalo messaging
Q1: Maxaa ay ku jiraan koonfurta Rockwell ee la isticmaalo PS69-DPM?
A1: PS69-DPM wuxuu la isticmaalo koonfurta Rockwell Automation CompactLogix ee leh 1769 I/O bus capability, sidoo kale koonfurta MicroLogix 1500 LRP ee leh 1764-LRP/A Rev.2.0 processor . Booska CompactLogix, RSLogix 5000 leh version 13.00 ama sare .
Q2: Sidaad u sameysaa isdhexdiimka PROFIBUS ugu dambeeyo PS69-DPM?
A2: Isdhexdiimka PROFIBUS waxaa sameysaa PROSOFT.fdt (SYCON.net) toolka isdhexdiimka. Xidh intarfeyska diyaagnostikka serial ee moduulka (kuwa lagu isticmaalo CABLE-SRV-MD8) ilaa portka COM ee PC-gaaga, kadibaa istaagma PROSOFT.fdt si aad u siiyo paramaaterka buska, u bixiso adreseedka slave-ka, oo u sameysato isdhexdiimka I/O .
Su’aal 3: PS69-DPM-kaaga waa la saaray Slot 1 ee processor 1768-L43/L45, laakiin ma aqoon. Waa maxay inaad sameysid?
A3: Tani waa shakhsiyeed aad ugu yar tahay RSLogix 5000 leh xusaysiis 18 iyo 19. Furoo waa inaad PS69-DPM-ka la saaro kuwa kale oo aan lahayn Slot 1 (oo kuwaas oo ku jira qaybta dhammaan ee power supply). Siyaasadda kale, waxaad karaan kala duwan ku dhigta RSLogix 5000 leh xusaysiis 16 ama ku guurta xusaysiis 20 marka la helo .
Su’aal 4: Ma PS69-DPM-ku ku talagalinaya DPV1 messaging kaalinta MicroLogix 1500?
A4: Maya. Markii PS69-DPM-ka la soo baxay, kaalintada MicroLogix 1500 ma ku talagalinaya CIP messaging kaalinta modules kuwa ah Compact I/O. Sidaa darteed, seerviisada DPV1 (MSAC1 Read/Write, Alarm Handling) ayaa lagu talagalinayaa marka la isticmaalayo processor CompactLogix oo ku talagalinaya CIP messaging. Kaalintada MicroLogix ayaa la xiriirayaa I/O cyclic iyo fankaha I/O-ka ah ee caadi ah ee ku saaraya tijaabo .
Su’aal 5: Ma PS69-DPM-ku ku saari karaa marka rack-ka la isticmaalo?
A5: Maya. PS69-DPM ma aha karo ku jira oo la bixi karo. Waa inaad ugu dambeysiiyey amal ka dhintay qorsho kaas oo aad ugu dhowdahay ama ugu bixisaysay qorsho kaas. Marka aan la sameeyn, waxaa laga yaabaa in qorsho kaas, processor-ka ama qorshooyinka kale ee la xidhiidh yahay ay ku dhintaan. .
Ogaada Hadda: [email protected]