IE/PB Link PN IO wuxuu kala duwanaya Industrial Ethernet iyo shabakada PROFIBUS ee hoos u jeedda. Wuxuu noqon karaa PROFINET IO proxy ama gateway caadi ah, waxaana ku xidha data ee project-ka ee ku jira flash memory-ka dhexeeya ama C-PLUG ee la isticmaalo.
Xaqiijinta leh wejiga iyo project-ka: Ku xaqiiji 6GK1411-5AB00 ee dhammaan ee order-ka, firmware-ka, shakhsiyaadka la xaqiijiyey ee la isticmaalo, STEP 7 hardware entry, magaca qorsho ee Ethernet iyo IP parameters, PROFIBUS address iyo rate, DP slave list iyo macluumaadka C-PLUG ilaa marka la xaqiijiyo in la isticmaalo ama in la badalo.
Quruxa Qorsho
6GK1411-5AB00 waa SIMATIC NET IE/PB Link PN IO gateway ee kuwa soo socda. Qorsho ee Ethernet-ka wuxuu leeyahay 10/100 Mbit/s communication, halkaasoo qorsho ee PROFIBUS-ka wuxuu leeyahay 9.6 kbit/s ilaa 12 Mbit/s, waxaana noqon karaa DP master ee shabakada hoos u jeedda ee meelaha.
Badba waxaa la isticmaala karaa in la xaqiijiyo si loo beddelo, isla markaana waxyaabaha ka soo baxa ah. Haddii habka geedka la isticmaalo, magaca qofka, IP iyo sooradaha PROFIBUS, xoolaha firmware iyo daata C-PLUG ay la isticmaalo, waa in la xaqiijiyo sida la jiray in la dhisayo xiriirka iyo in dhamaan DP slaves ay ugu soo noqdaan habka dhaqameed.
Qeybta Ethernet iyo PROFIBUS waa in la dhisayo mar walba sida geedka la isticmaalo.
PROFINET identity
Qor magaca qofka, tusaalega IP, ku saabsiga controller iyo habka la isticmaalo ee proxy ilaa in geedka badan la qaado.
Qeybta PROFIBUS
Ku dhaqan gacanta DP master, xarajka baud, tartibka slave, ku dhaqan korka iyo qofka ugu horreeya iyo ugu dambeeya ee qeybta.
Mode kaalmada
Qor in ay qofka uu yahay PROFINET IO iyo geed, ama geed caadi ah; in la beddelo habka waa in la dhisayo mar walba.
C-PLUG Iyag-kuwaad
Ugu yar yahay in C-PLUG uu la isticmaalo sida meel la isticmaalo oo leh xoojinta, aan la isticmaalo sida meel la isticmaalo oo leh xoojinta.
Habka la isticmaalo marka la qaado amal
Gudub ama ka saar C-PLUG oo kaliya marka la qaado amal iyo ku dhaqan habka la isticmaalo iyo qofka la isticmaalo.
Xaqiijin natiijada
C-PLUG aan la xiriirin karo ama aan la qorin karo wuxuu ku dhaqaaqayaa gateway-ka STOP ka marka laga helo xalad; eeg in data-ka ay ku jiraan ilaa in la guurinayo.
Tilmaamaha fikradaha la xidhiidhay
Isticmaal BF PN, BF DP, SF, RUN iyo STOP iyadoo la isticmaalo NCM diagnostics si aad uga hortagtaan isku dhafan-kii aan la xiriirin karo ilaa in la guurinayo.
Xoggaarka
Magaca ahaanta mawduuca
SIMATIC NET IE/PB Link PN IO
Taksiimada Fadlan
6GK1411-5AB00
Wajibaadka Shakshooyinka
Industrial Ethernet ilaa PROFIBUS gateway
Haliyada shaqaynta
PROFINET IO proxy ama gateway caadi ah
Xiriirka Ethernet
RJ45, 10/100 Mbit/s
Qaybta Profibus
9-pin Sub-D, 9.6 kbit/s ilaa 12 Mbit/s
DP slave capacity
Ugu yar 64 devices ee PROFINET IO proxy loo isticmaalo
Waa maxay inaad sameysid C-PLUG marka 6GK1411-5AB00 loo badalo?
Ugu dambaystii, fahminta in C-PLUG wuxuu leeyahay data muhiimka ah ee projectka kan gateway. Ka saar dhinaca jirka ilaa marka la guurin, daaqadda ka soo bixi iyo kuwa la guurin waxaad ku xaqiijinaysaa natiijada guurka; C-PLUG aan la xiriira noqon karaa in guurka loo dhaqanayo STOP iyo xalad.
BF PN waxa uu ku saabsan yaa xiriirka controllerka PROFINET, magaca qofka, xidhka Ethernet ama dhammaan ka qorsho. BF DP waxa uu ku saabsan projeedta PROFIBUS ee la xidhiidha, qaybta fizioogiga ama slave ka kala duwan. Xaqiiji BF DP iyo BF PN, RUN iyo STOP, oo isku day inaad isticmaasho nadiifka NCM.
Q4
Maxaa yeelay 6GK1411-5AB00 waa inuu la soo noqdo marka la badalo shakhsiyaadka proxy ilaa shakhsiyaadka gateway kaliya?
Shakhsiyaadka horumarinta waxa uu badalo qorshada la kaydsho. Siemens waxa uu u baahan yahay in 6GK1411-5AB00 la soo noqdo ilaa xaladaha asaasiga ah marka la badalo shakhsiyaadka la kaydsho, kadibna waa in projeedta STEP 7 iyo paramaateriyada shabakadda la soo gudbiyo mar kale.
Q5
Maxaa yeelay 6GK1411-5AB00 waa inuu leeyo xidhka Ethernet laakiin ma leeyo daaweynta dhexeeya ka imanaya qofka PROFIBUS?
Xaqiiji in magaca qofka iyo xiriirka controllerka ay tahay sax ah, kadibna xaqiiji aadreska DP master, xaladaha, xidhka dhexeeya iyo qorshada slave. Isticmaal BF DP iyo nadiifka si aad u hesho slaveka kooxda kala duwan ee ugu horreeya, laakiin ha aad badalo xidhka Ethernet oo aan la jiro.
Q6
Ma aha 6GK1411-5AB00 ku dabaqan karaa PROFIBUS masters kaalayn oo ku jira iyadoo la isticmaalayo xagga caadiga ah?
Ha ugu yeedho inaannu tani ku dhawaaqo waa master-to-master coupler oo wax yaab leh. Xagga PROFIBUS ee uu ku jiro waa master oo ku saabsan DP slaves; nidaamka oo u baahan yahay inuu soo bandhigo daata baynna laba masters waa inuu leeyo foomiyeed ay ku jiraan kuwaas oo la sameeyo.