Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6gk5778 1gy00 0aa0 scalance w778 1 m12 iwlan access point-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6GK5778-1GY00-0AA0 SCALANCE W778-1 M12 IWLAN Access Point

Product Name: SCALANCE W778-1 M12 Industrial Wireless Access Point
Brand Name: Siemens
Model Number: 6GK5778-1GY00-0AA0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Commercial Term
  • Specifications
  • Contact info
  • Description
  • Function
  • About Company
  • FAQ
  • Other Products
  • Recommended Products
Single-Radio IWLAN with an Integrated Two-Port M12 Switch

Siemens 6GK5778-1GY00-0AA0 is a SCALANCE W778-1 M12 industrial wireless access point with one radio and an integrated two-port Ethernet switch.

Use the exact Siemens order number 6GK5778-1GY00-0AA0 when matching an installed unit, project or service spare.

Commercial Term

QUOTATION PAYMENT LEAD TIME SHIPPING WARRANTY
Current price and availability
T/T or agreed terms
Confirmed with the quotation
DHL, FedEx, UPS or agreed freight
12 months

Specifications

Technical parameter Value
Product type designation
SCALANCE W778-1 M12
Article number
6GK5778-1GY00-0AA0
Regional version
Outside USA and Israel
Wireless radios
1
Wireless standards
IEEE 802.11a/b/g/h/n
Antenna connections
2 × N-CON
Ethernet interfaces
2 × M12, up to 100 Mbps
Network function
Integrated two-port switch
Degree of protection
IP65
Manufacturer
Siemens

Contact info

Description

The single-radio design of 6GK5778-1GY00-0AA0 supports IEEE 802.11a/b/g/h/n operation with two N-CON antenna connections and 2 × 2 MIMO. Two M12 Fast Ethernet ports form an integrated switch for rugged device-level network attachment.

Siemens designates 6GK5778-1GY00-0AA0 for use outside the USA and Israel. Regional radio rules, antenna selection, KEY-PLUG functions and loop-free wiring of the two-port switch should be established before the access point is deployed.

Function

Single-radio IWLAN
Operate one 2.4 GHz or 5 GHz industrial wireless radio path.
Two-port wired network
Use the two M12 Fast Ethernet ports as an integrated switch.
External antenna system
Connect the documented two-antenna 2 × 2 MIMO arrangement.
Wide-temperature enclosure
Deploy the IP65 device within its documented industrial environment.

About Company

SupplyPLCs supports global industrial automation sourcing with exact-model review, product-condition confirmation and responsive quotation service.

Share the complete order number, installed-system context and destination with our team. We will coordinate availability, shipment options and the documentation available for the requested product.

FAQ

Q1. Is 6GK5778-1GY00-0AA0 appropriate for an IWLAN installation in the United States or Israel?
Answer: No regional assumption is safe. Siemens identifies this order number for use outside the USA and Israel, so select a region-approved variant before work continues in either country.
Q2. Why can a second M12 cable on 6GK5778-1GY00-0AA0 create an unexpected network loop?
Answer: The two M12 interfaces form an integrated switch rather than two independent routed networks. Trace both cable paths and keep only the topology approved by the network design before enabling the second connection.
Q3. How should I choose the antenna arrangement for 6GK5778-1GY00-0AA0 in a metal machine area?
Answer: Use the two N-CON connections as one documented 2 × 2 MIMO radio system. Position and select both antennas from an RF survey; do not treat an unused or mismatched antenna path as normal commissioning.
Q4. What should be checked when 6GK5778-1GY00-0AA0 joins the wired network but wireless clients cannot associate?
Answer: Separate the M12 Ethernet path from the radio path. Confirm the configured band, channel, security profile and antenna connections, then test one approved client before changing the wired switch settings.
Q5. When does the IP65 rating of 6GK5778-1GY00-0AA0 no longer describe the installed assembly?
Answer: The rating depends on sealed M12 and N-CON connections and an intact housing. Stop environmental acceptance if any unused connector is open, a seal is damaged or the selected cable hardware lacks the required protection.
Q6. Which configuration items should be retained before replacing 6GK5778-1GY00-0AA0 in a running cell?
Answer: Retain the management address, radio profile, security settings, KEY-PLUG status and both M12 cable destinations. This record prevents the service unit from creating a different wireless role or wired topology.

Other Products

XF830A
SDI-OE-S
NA200T IZMX-RP16A-200
LFI520
4100LR12
SC200-00
SCD2200-RTU PS-22
IC200MDD844F
IC200MDL650L
ABB 1SDH001000R0505-B0821
BS6151 01 SP01
ZBRN2
FGR-002
AMAX-2241
8530D-I
THS710
105S-1
SC42-EP08
AMAX-2241/PMA
ADAP-KOOL
eWONx005CD
CH-LMD1
SP-0108-H2
ABB 2CDG110137R0011
IMD-IM20 / IM20DEMO
Abb 3BSE038226R1
SWH-4200
ABE7 P16T334
81672-01
LP/ 557-180-203

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000