| Modellum | 07EA63R1 |
|---|---|
| Familia producti | Procontic T200 |
| Typus Producti | módulo de ingreso analógico de 8 canales y alta resolución |
| Número de pedido ABB | GJV3074353R1 |
| Systema | Procontic T200 |
| Canali Ingressus | 8 |
| Signum input | 4 ad 20 mA |
| Resolutio | 12 bit |
| Isolatio Electrica | Potencial de referencia común aislado del sistema |
| Tensión nominal de aislamiento | 60 VCA |
| Test voltage | 500 V AC |
| Limitis Apertus Limen | Circa 3.76 mA |
| Resistentia input | 100 ohm |
| Resolutio Tensionis | 3.97 µA |
| Exactitudo Distributionis | ±1% |
| Error Resolutions | ±0.5 LSB |
| Non-Linearitas | ±0.5 LSB |
| Temperatus coefficientis | ±0.347 µA/K |
| Maximus Correntis Ingressus | +40 mA / -5 mA |
| Conversio Tempus | 5 ms |
| currente de alimentatione de 5 V | 60 mA maximum |
| currente de alimentatione de 24 V | 190 mA maximum |
| Dispergo Potentiam | 4.86 W maximum |
| Longitudo Cavi Scutati | 50 m standardis; usque ad 200 m cum duobus animis scutatis cable ≥0.5 mm² |
| Terminalis Conductor | 1.5 mm² maximum |
| Puncta I/O occupata | 128 |
| Identifier | EW8 |
| Pondus | 0.50 kg |
| Minimum quantitas ordinis | 1 piece |
|---|---|
| Pretium | Contactus pro Jim |
| Singula Packaging | Novus Originalis, Sigillatus a Fabrica |
| Tempus Traditionis | 3–7 dies |
| Condiciones solutionis | T/T |
| Shipping modum | DHL / FedEx / UPS / TNT |
| Capacitas Supplicandi | Novus prorsus, in stock |
Integratus ut ABB 8-channelis altae resolutionis analogus input modulorum, 07EA63R1 ad Procontic T200 platformam pertinet. Octo 4–20 mA campi circuitus duodecim-bitum mensurationem resolutionem praebet. Specifica modello dispositio totum input gruppus a Procontic T200 systematis electronicis isolat. Suus installatus interfacies finem currentem resolutionem cum aperto-circuitu supervisione prope 3.76 mA combinat. Haec characteristicas exactum hardware limitem definunt quod imitari oportet cum hoc componente in existenti systemate quaeritur.
Cum iterum signum via restituitur, 07EA63R1 supports higher-resolution transmitters while maintaining the documented fine process trending path. The component is especially relevant where line-break detection must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern precision retrofit planning. Requires the same shield, common and channel assignment used by the installed module. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.
| 3-12/S1RY | 2CDG 110 063 R0011 | ML50105 |
| PSR-SCP 24DC/ESP4/2X1/1X2 PSR-ESP4 | SB-Logic2 -DN | K1225 K1225/1 |
| DCP2-2405 /1240020009A | 7900-0211-500rp WD5-BIAS | KNX 2CDG 110 085 R0011 |
| UCL-16DI.DI | 74-115968-04 TTC5-09 | SG-TL70-Y |
| Pilz 751107 | DM-RMC-4K-100-C | 1SAP220500R0001 |
| SDV531-L33/PRP | PSR-SCP-24DC/ESP4/2X1/1X2 | 647593 reg-k/4x230/16 |
| ABB 2CDG 110 085 R0011 | EST3 SFS1-ELEC | PAC-150WA |
| RXV-35-4K / 4K | USW333 | IO111 |
| HT9611D3100 | 2CDG110080R0011 | 2CDG 110 046 R0011 |
| SB401-50 | HT22 | ET12 |
| 1SAP220500R0001 CS31 | USW 333 | VT9611D3100-BACnet |
| PSR-SCP- 24DC/ESP4/2X1/1X2 | ABB 2CDG 120 039 R0011 | MBC5100 061B000266 |
| K1225 | RXV-35-4K/4K | SCMD6400 |