| Sales | Phone/Whatsapp | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model | 07EA63R1 |
|---|---|
| Product Family | Procontic T200 |
| Product Type | 8-channel high-resolution analog input module |
| ABB Order Number | GJV3074353R1 |
| System | Procontic T200 |
| Input Channels | 8 |
| Input Signal | 4 to 20 mA |
| Resolution | 12 bit |
| Electrical Isolation | Common reference potential isolated from system |
| Nominal Insulation Voltage | 60 VAC |
| Test Voltage | 500 VAC |
| Open-Circuit Threshold | Approximately 3.76 mA |
| Input Resistance | 100 ohm |
| Current Resolution | 3.97 µA |
| Delivery Accuracy | ±1% |
| Resolution Error | ±0.5 LSB |
| Non-Linearity | ±0.5 LSB |
| Temperature Coefficient | ±0.347 µA/K |
| Maximum Input Current | +40 mA / -5 mA |
| Conversion Time | 5 ms |
| 5 V Supply Current | 60 mA maximum |
| 24 V Supply Current | 190 mA maximum |
| Power Dissipation | 4.86 W maximum |
| Shielded Cable Length | 50 m standard; up to 200 m with 2-core shielded cable ≥0.5 mm² |
| Terminal Conductor | 1.5 mm² maximum |
| Occupied I/O Points | 128 |
| Identifier | EW8 |
| Weight | 0.50 kg |
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
Integrated as a ABB 8-channel high-resolution analog input module, 07EA63R1 belongs to the Procontic T200 platform. It provides twelve-bit measurement resolution for eight 4–20 mA field loops. The model-specific arrangement isolates the complete input group from the Procontic T200 system electronics. Its installed interface combines fine current resolution with open-circuit supervision near 3.76 mA. These characteristics define the exact hardware boundary that must be matched when the component is sourced for an existing system.
When restoring the signal path, 07EA63R1 supports higher-resolution transmitters while maintaining the documented fine process trending path. The component is especially relevant where line-break detection must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern precision retrofit planning. Requires the same shield, common and channel assignment used by the installed module. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.
| 3-12/S1RY | 2CDG 110 063 R0011 | ML50105 |
| PSR-SCP 24DC/ESP4/2X1/1X2 PSR-ESP4 | SB-Logic2 -DN | K1225 K1225/1 |
| DCP2-2405 /1240020009A | 7900-0211-500RP WD5-BIAS | KNX 2CDG 110 085 R0011 |
| UCL-16DI.DI | 74-115968-04 TTC5-09 | SG-TL70-Y |
| Pilz 751107 | DM-RMC-4K-100-C | 1SAP220500R0001 |
| SDV531-L33/PRP | PSR-SCP-24DC/ESP4/2X1/1X2 | 647593 reg-k/4x230/16 |
| ABB 2CDG 110 085 R0011 | EST3 SFS1-ELEC | PAC-150WA |
| RXV-35-4K / 4K | USW333 | IO111 |
| HT9611D3100 | 2CDG110080R0011 | 2CDG 110 046 R0011 |
| SB401-50 | HT22 | ET12 |
| 1SAP220500R0001 CS31 | USW 333 | VT9611D3100-BACnet |
| PSR-SCP- 24DC/ESP4/2X1/1X2 | ABB 2CDG 120 039 R0011 | MBC5100 061B000266 |
| K1225 | RXV-35-4K/ 4K | SCMD6400 |