Bently Nevada 24701 Series 24701-28-05-XX-117-03-XX MOD:323933-00-02 Modified Stainless Steel Proximity Probe Housing Assembly | Original New

BENTLY NEVADA | SÉRIE 24701
24701-28-05-XX-117-03-XX MOD:323933-00-02
Ensemble boîtier de sonde de proximité en acier inoxydable modifié
Selectio: 3300 XL 8 mm probe with approval option | 0.5 m cable | 11.7 in probe penetration | one 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer and one cable seal grip | modification 323933-00-02
Tempus ducens: In stock | Garantia: unum annum
Appurtenance:
  • Conspectus
  • Data Technica
  • Inquisitio
  • Construction
  • Dux Selectionis
  • Installatio
  • Ambiens et Approbationes
  • Quaestiones Frequentes
  • Modellos Recommandatos
  • Producta commendata
SUMMARIVM OFFICIALE PRODUCTI
24701 Stainless Steel Proximity Probe Housing Assembly
An all-metal externally mounted proximity probe housing assembly with a 303 stainless steel body, 304 stainless steel sleeve and installed reverse-mount proximity probe. The assembly provides external access for probe gap adjustment or replacement without machine disassembly.
Configuratio exacta: Option 28 selects a 3300 XL 8 mm probe with approval option; 05 selects a 20 in (0.5 m) probe cable; 023 selects 11.7 in probe penetration; 03 selects one 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer and one cable seal grip. The XX fields and MOD 323933-00-02 are modification-controlled and are not decoded in the public datasheet.

Data Technica

Data Technica
Official 24701 housing data and decoded public order-code fields
Modello completo
24701-28-05-XX-117-03-XX MOD:323933-00-02
Familia producti
24701 Proximity Probe Housing Assembly
Typus Producti
Modified stainless steel externally mounted proximity probe housing assembly with installed reverse-mount probe
Dimensiones
24701 basihousing: A 78.2 mm (3.08 in), B 151.9 mm (5.97 in), E 27.9 mm (1.10 in); seligitur penetratio probae D est 11.7 in (297.2 mm); distantia C et filum fixationis F designantur per XX et reguntur per modificatio
Pondus
1.8 kg (4.1 lb) typice pro 24701 housing sine adiunctis
Materia habitationis
303 stainless steel body with 304 stainless steel sleeve
Selectio probae
Optio 28: proba 3300 XL 8 mm cum optione approbationis
Longitudo Cavi Exploratoris
Optio 05: 20 in (0.5 m)
Penetratio probae
Optio 117: 11.7 in (297.2 mm), regulabilis per 13 mm (+/- 0.5 in)
Selectio adiunctorum
Optio 03: unus obturator 3/4-14 NPT, unus reductor 3/4-14 ad 1/2-14 NPT, et unus prehensor cavi cum grommetis pro intervallo cavorum 1/8 ad 3/8 in
Adaptator Intermedius
XX: valor regendus a modificatione; non definitus in tabula publica ordinandi
Tactus Montandi
XX: valor regendus a modificatione; non definitus in tabula publica ordinandi
Temperatura di funzionamento e di stoccaggio della sonda
proba 3300 XL 8 mm: -51 ad +177 °C (-60 ad +351 °F)
Housing compliance
API 670 compliant for externally mounted proximity probe housings; RoHS Directive 2011/65/EU
Hazardous-area selection
Probe option 28 includes an approval option; exact installed approvals must follow the product marking and official approvals guide
Modificatio
MOD 323933-00-02; modification details are not published in datasheet 141600

Construction

Construction
All-metal housing
The 24701 assembly uses a 303 stainless steel body and a 304 stainless steel probe sleeve.
Service Access
The threaded dome cover permits external access for probe adjustment or replacement without dismantling the machine.
Installed sensing element
Option 28 supplies a reverse-mount 3300 XL 8 mm proximity probe with an approval option.
Interfácia conductus
Optio aptationis electa praebet obturatorem 3/4-14 NPT, reductorum 3/4-14 ad 1/2-14 NPT et prehensorum cavi catenarii; interfácia montandi manet sub controllo modificationis.
Key selection note: Tabula data publica non explicat duo campos XX nec detailes mechanicorum MOD 323933-00-02.

Dux Selectionis

Dissectio Numeri Partis
24701-28-05-XX-117-03-XX MOD:323933-00-02
24701
Stainless Steel Proximity Probe Housing Assembly
28
probator 3300 XL 8 mm cum optione approbationis
05
20 in (0.5 m) probe cable
XX
Valor adaptatoris distantis sub controllo modificationis
117
11.7 in probe penetration
03
Unus obturator 3/4-14 NPT, unus reductor 3/4-14 ad 1/2-14 NPT et unus prehensor cavi catenarii
XX
Valor fileti montandi sub controllo modificationis
MOD 323933-00-02
Referentia modificatiōnis clientis aut proiectūs; dētālia nōn publicāta in documentō 141600

Installatio

Installatio
Locus fixationis
Utere ad montāgēm externam per cāsum māchinīs cum accessū ad prōbam et ductum ā extrā māchinīs.
Impōnēns penetrātiōnis
Penetratio selecta de 11.7 in habet officialem ambitum adaptationis de 13 mm (+/- 0.5 in). Distantia interposita sub controllo modificationis debet tenere summam C plus D intra limitem publicatum cavi.
Auxilium tubae
Pro cavo probae de 0.5 m, distantia interposita totalis plus penetratio C+D non debet excedere 13.5 in (343 mm); adde supportum manicae si C+D excedit 12 in (300 mm).
Ductus prōbae
Ductus prōbae dēbet esse longior quam manīca installāta, et directiō servāre dēbet accessum ad servitium sub tegmine domōs.
Key selection note: Confirma distāntiam inter medium et punctum montāgiī sub contrōle modificātiōnis et filetum montāgiī ex tabellā nominālī physica aut ex schemāte modificātiōnis approbātō antequam machinēs faciās.

Ambiens et Approbationes

Ambiens et Approbationes
Līmitēs familiae publicātī et informātiō de conformitāte
Probe Temperature
3300 XL 8 mm prōba operātiōnis et stōrāgiī: -51 ad +177 °C
Materia habitationis
corpus ex acciaio inossidabile 303; manicotto ex acciaio inossidabile 304
Environmental Enclosure
custodie 24701 disponibiles ut configurationes custodiarum CSA Typus 4
Compliantia ad API
Conformis API 670 pro custodiis externis proborum proximitatis
Obsequium RoHS
Directiva RoHS Communitatis Europaeae 2011/65/UE
Selectio approbationis
Optio 28 praebet configurationem probi cum approbatione ad zonas periculosas selectibilem
Distinctio explosion-proof
Solae configurationes CA24701 ordinatae sub condicionibus applicabilibus CSA identificantur ut explosion-proof in folio publico datarum

Quaestiones Frequentes

Sex controllationes emptionis specificae pro modulo
Quomodo procuratio confirmare potest configurationem 11,7 pollicum citatam?
Require the full code 24701-28-05-XX-117-03-XX MOD:323933-00-02 on the quotation, nameplate and packing label. Independently verify the 0.5 m cable, option 117 penetration and option 03 fitting package.
How should condition be checked for this long-sleeve assembly?
Inspect the 11.7 in penetration section for bending, scratches and prior clamp marks, and check the probe tip, 0.5 m cable, reducer, cable seal grip, plug and dome threads for installation or repair evidence.
What makes a supplier credible for this modified housing?
Verify the registered company, physical address, beneficiary account, traceable offer and written New condition. A reliable quotation identifies MOD 323933-00-02 and does not omit either XX field.
What must engineers validate before releasing the purchase?
Confirm the 3300 XL 8 mm probe, 0.5 m lead, 11.7 in penetration, option 03 fittings, actual C standoff and F mounting thread. Total C+D must remain within the published 13.5 in cable limit.
Quae probatio praepretii ad optionem 117 idonea est?
Petite photographemae datae totius nominis et notae mutationis, mensuram ostendentem 11.7 in penetratione, integrum coniunctionum apparatum, apicem probae et caleum, necnon schemata approbata pro utrisque dimensionibus XX.
Num codex penetrationis proximus aut optio coniunctionis substitui potest?
Nulla substitutio automatica admittitur. Mutatio 117, optionis 03, longitudinis calei, vel campi XX vel referentiae MOD longitudinem C+D, necessitates sustentationis, connexionem tubi et aptitudinem installationis mutare potest.

Modellos Recommandatos

Random cross-brand reference list
ZG31/EX
HT22
GP070-ET41
4300-54
BAP1728
6SE6400-3TC00-4AD2
2CDG110091R0011
45196504
400116900 34001168XD-2FA
AMM-2F
Dba-ea43/A10rh
028126 DMX3
f170
4100LR12
ABB DIS0002 2RAA005802A0001H
SR-508
El-805u-d-868-500m
SC-MV04FL
100-02823
407860
4100 565-226
EZE-AC750T
ST-IO ZA10341
TPS-6L
05605121
KFD2-GUT-1.D PN:231224
BCM603-2S
CHV-TSTATB
176F3422
DP0100-AZ
C2IR-8
ABB DA502-XC 1SAP450800R0001 1SAP 450800R0001
2CDG1101121R0011
2CDG 110 161R0011
400017 6DI
SL-2000-P
L01-2985-000
TT100
CR104PLG22W
1SVR430801R1100
GMP201-C
BM12 616-661
ABB DAB 210000
216/CC/VH/DCX/R/XXX/G/ENG
1222210010
FW-325
JL325A JL325-61001
MTL4575
TW-2.0
REV:6.0 PN:CEPL130322-07
46779C-2 PR50 73107M
67CFR-600
ABB 83111-500-02 2TMA210010N0038
330130-075-01-05
Siemens 3TF3001-0XL2
LH-1310
PMT50Ex-2-AO-2R-00-5-13
ADV151 ADV151-E10
CK70 CK70AA5KNU3W2100
A06B-6081-H101

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Mobilis
Nomen societatis
Nuntius
0/1000