BENTLY NEVADA | 24701 SERIES
24701-28-05-XX-117-03-XX MOD:323933-00-02
Modified Stainless Steel Proximity Probe Housing Assembly
|
|
Selection: 3300 XL 8 mm probe with approval option | 0.5 m cable | 11.7 in probe penetration | one 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer and one cable seal grip | modification 323933-00-02
LEAD TIME: In stock | WARRANTY: 1 year
|
OFFICIAL PRODUCT SUMMARY
24701 Stainless Steel Proximity Probe Housing Assembly
An all-metal externally mounted proximity probe housing assembly with a 303 stainless steel body, 304 stainless steel sleeve and installed reverse-mount proximity probe. The assembly provides external access for probe gap adjustment or replacement without machine disassembly.
|
Exact configuration: Option 28 selects a 3300 XL 8 mm probe with approval option; 05 selects a 20 in (0.5 m) probe cable; 023 selects 11.7 in probe penetration; 03 selects one 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer and one cable seal grip. The XX fields and MOD 323933-00-02 are modification-controlled and are not decoded in the public datasheet. |
|
Technical Data
Official 24701 housing data and decoded public order-code fields
|
|
Complete model
|
24701-28-05-XX-117-03-XX MOD:323933-00-02
|
|
Product family
|
24701 Proximity Probe Housing Assembly
|
|
Product type
|
Modified stainless steel externally mounted proximity probe housing assembly with installed reverse-mount probe
|
|
Dimensions
|
24701 base housing: A 78.2 mm (3.08 in), B 151.9 mm (5.97 in), E 27.9 mm (1.10 in); selected probe penetration D is 11.7 in (297.2 mm); standoff C and mounting thread F are represented by XX and controlled by the modification
|
|
Weight
|
1.8 kg (4.1 lb) typical for 24701 housing without fittings
|
|
Housing material
|
303 stainless steel body with 304 stainless steel sleeve
|
|
Probe selection
|
Option 28: 3300 XL 8 mm probe with approval option
|
|
Probe cable length
|
Option 05: 20 in (0.5 m)
|
|
Probe penetration
|
Option 117: 11.7 in (297.2 mm), adjustable by 13 mm (+/- 0.5 in)
|
|
Fitting selection
|
Option 03: one 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer, and one cable seal grip with grommets for 1/8 to 3/8 in cable ranges
|
|
Standoff adapter
|
XX: modification-controlled value; not defined in the public ordering table
|
|
Mounting thread
|
XX: modification-controlled value; not defined in the public ordering table
|
|
Probe operating and storage temperature
|
3300 XL 8 mm probe: -51 to +177 deg C (-60 to +351 deg F)
|
|
Housing compliance
|
API 670 compliant for externally mounted proximity probe housings; RoHS Directive 2011/65/EU
|
|
Hazardous-area selection
|
Probe option 28 includes an approval option; exact installed approvals must follow the product marking and official approvals guide
|
|
Modification
|
MOD 323933-00-02; modification details are not published in datasheet 141600
|
|
CONTACT
STELLA
|
|
Construction
|
|
All-metal housing
The 24701 assembly uses a 303 stainless steel body and a 304 stainless steel probe sleeve.
|
Service access
The threaded dome cover permits external access for probe adjustment or replacement without dismantling the machine.
|
|
Installed sensing element
Option 28 supplies a reverse-mount 3300 XL 8 mm proximity probe with an approval option.
|
Conduit interface
The selected fitting option supplies a 3/4-14 NPT plug, a 3/4-14 to 1/2-14 NPT reducer and a cable seal grip; the mounting interface remains modification-controlled.
|
|
Key selection note: The public datasheet does not decode the two XX fields or the mechanical details of MOD 323933-00-02.
|
|
|
Part number breakdown
24701-28-05-XX-117-03-XX MOD:323933-00-02
|
|
24701
|
Stainless steel proximity probe housing assembly
|
|
28
|
3300 XL 8 mm probe with approval option
|
|
05
|
20 in (0.5 m) probe cable
|
|
XX
|
Modification-controlled standoff adapter value
|
|
117
|
11.7 in probe penetration
|
|
03
|
One 3/4-14 NPT plug, one 3/4-14 to 1/2-14 NPT reducer and one cable seal grip
|
|
XX
|
Modification-controlled mounting thread value
|
|
MOD 323933-00-02
|
Customer or project modification reference; details not published in document 141600
|
|
Installation
|
|
Mounting location
Use for external mounting through the machine case with access to the probe and lead from outside the machine.
|
Penetration setting
The selected 11.7 in penetration has an official adjustment range of 13 mm (+/- 0.5 in). The modification-controlled standoff must keep total C plus D within the published cable limit.
|
|
Sleeve support
For the 0.5 m probe cable, total standoff plus penetration C+D must not exceed 13.5 in (343 mm); add sleeve support if C+D exceeds 12 in (300 mm).
|
Probe lead
The probe lead must be longer than the installed sleeve, and routing must preserve service access under the dome cover.
|
|
Key selection note: Confirm the modification-controlled standoff and mounting thread from the physical nameplate or approved modification drawing before machining the installation.
|
|
|
Environment & Approvals
Published family limits and compliance information
|
|
Probe temperature
|
3300 XL 8 mm probe operating and storage: -51 to +177 deg C
|
|
Housing material
|
303 stainless steel body; 304 stainless steel sleeve
|
|
Environmental enclosure
|
24701 housings are available as CSA Type 4 enclosure configurations
|
|
API compliance
|
API 670 compliant for externally mounted proximity probe housings
|
|
RoHS compliance
|
European Community RoHS Directive 2011/65/EU
|
|
Approval selection
|
Option 28 provides a selectable hazardous-area approval probe configuration
|
|
Explosion-proof distinction
|
Only CA24701 configurations ordered under the applicable CSA conditions are identified as explosion-proof in the public datasheet
|
|
Six model-specific purchase checks
|
|
How can procurement confirm the quoted 11.7 in configuration?
Require the full code 24701-28-05-XX-117-03-XX MOD:323933-00-02 on the quotation, nameplate and packing label. Independently verify the 0.5 m cable, option 117 penetration and option 03 fitting package.
|
|
How should condition be checked for this long-sleeve assembly?
Inspect the 11.7 in penetration section for bending, scratches and prior clamp marks, and check the probe tip, 0.5 m cable, reducer, cable seal grip, plug and dome threads for installation or repair evidence.
|
|
What makes a supplier credible for this modified housing?
Verify the registered company, physical address, beneficiary account, traceable offer and written New condition. A reliable quotation identifies MOD 323933-00-02 and does not omit either XX field.
|
|
What must engineers validate before releasing the purchase?
Confirm the 3300 XL 8 mm probe, 0.5 m lead, 11.7 in penetration, option 03 fittings, actual C standoff and F mounting thread. Total C+D must remain within the published 13.5 in cable limit.
|
|
Which prepayment evidence is appropriate for option 117?
Ask for dated photos of the full nameplate and modification mark, a measurement showing 11.7 in penetration, the complete fitting set, probe tip and cable, plus the approved drawing for both XX dimensions.
|
|
Can a nearby penetration code or fitting option be substituted?
No automatic substitution is acceptable. Changing 117, option 03, the cable length, either XX field or the MOD reference can alter C+D length, support requirements, conduit connection and installation fit.
|
|
Random cross-brand reference list
|
|
ZG31/EX
|
HT22
|
GP070-ET41
|
|
4300-54
|
BAP1728
|
6SE6400-3TC00-4AD2
|
|
2CDG110091R0011
|
45196504
|
400116900 34001168XD-2FA
|
|
AMM-2F
|
Dba-ea43/A10rh
|
028126 DMX3
|
|
f170
|
4100LR12
|
ABB DIS0002 2RAA005802A0001H
|
|
SR-508
|
El-805u-d-868-500m
|
SC-MV04FL
|
|
100-02823
|
407860
|
4100 565-226
|
|
EZE-AC750T
|
ST-IO ZA10341
|
TPS-6L
|
|
05605121
|
KFD2-GUT-1.D PN:231224
|
BCM603-2S
|
|
CHV-TSTATB
|
176F3422
|
DP0100-AZ
|
|
C2IR-8
|
ABB DA502-XC 1SAP450800R0001 1SAP 450800R0001
|
2CDG1101121R0011
|
|
2CDG 110 161R0011
|
400017 6DI
|
SL-2000-P
|
|
L01-2985-000
|
TT100
|
CR104PLG22W
|
|
1SVR430801R1100
|
GMP201-C
|
BM12 616-661
|
|
ABB DAB 210000
|
216/CC/VH/DCX/R/XXX/G/ENG
|
1222210010
|
|
FW-325
|
JL325A JL325-61001
|
MTL4575
|
|
TW-2.0
|
REV:6.0 PN:CEPL130322-07
|
46779C-2 PR50 73107M
|
|
67CFR-600
|
ABB 83111-500-02 2TMA210010N0038
|
330130-075-01-05
|
|
Siemens 3TF3001-0XL2
|
LH-1310
|
PMT50Ex-2-AO-2R-00-5-13
|
|
ADV151 ADV151-E10
|
CK70 CK70AA5KNU3W2100
|
A06B-6081-H101
|