Bureau des ventes directes
Un seul point de contact pour les devis, les livraisons et le soutien aux commandes.
|
VENDITE | Epistula electronica | Telephus WhatsApp |
|---|---|---|---|
| Iimus Pei | [email protected] | +86 18020776782 |
| Modellum | T8431C |
| Architectura Ingressus | Redundantia modularis triplex (TMR) |
| Numerus Entratarum | 40 |
| Signum input | 4-20 mA |
| Supported field device type | Sourcing input devices |
| Coating Conformativum | Ita |
| Backplane Supply Voltage | 20 to 32 V DC |
| Potentia | 20 W |
| Locus Modi | T8100 or T8300 I/O module slot |
| Isolatio Communis Campi | 50 V reinforced, continuous |
| Field common fault insulation | 250 V basic |
| Examen typi isolationis | 2436 V DC for 60 s |
| Isolātiō inter canālēs | Nessun isolamento canale-canale |
| Fusio | No module fuses |
| FTA input impedance | 250 ohm |
| Impedantia intrantis moduli | 16,967 kohm |
| Intervalum Currentis Ingressus | 0 ad 22 mA |
| Input voltage range | 0 usque ad 5,5 V DC |
| Limites inputus | Configurable per channel |
| Resolutio | 3,906 microamperium |
| Accuratio Securitatis | +/-200 microamperium |
| Accuratia calibratiunculae | +/-0.15% |
| Interfaciem Intrinsicam Securitatis | Barriera Externa Requiritur |
| Monitorium Lineae | Seligi potest pro singulis canalibus intrantium |
| Resistentia ad impulsum | 2500 V barriera isolans optica/galvanica |
| Resolutio ordinis eventuum | 1 ms |
| Accuratio temporis notati | +/-10 ms |
| Substitutio calida | Companion Slot aut SmartSlot |
| Certificatio securitatis | IEC 61508 SIL 3 |
| Temperatura operativa | 0 usque ad +60 gradus C |
| Temperatura servandae | −25 ad +70 gradus C |
| Humiditas operativa et servandi | 10% usque ad 95%, noncondensans |
| Dimensiones | 266 x 31 x 303 mm |
| Pondus | 1,149 kg |
|
Product Profile
Redundantia modularis triplex (TMR)
+ 40 ICS TRIPLEX / TRUSTED SAFETY I/O MODULES
|
T8431C est modus analogus Trusted TMR cum recubatione conformali, qui interfacit quadraginta canales campi sourcing per viam mensurae 4–20 mA. Tres sectores independens elaborant singulos introitus, dum diagnosis automatica superintendit modulo et eius coniunctionibus campi. Sogliae tensionis configurabiles permittunt controlleri statum canalis et statum defectus lineae determinare. Barriera isolationis impulsum sustinens 2500 V separat interfaciem campi ab electronicis systematis tutelaris. Modulus etiam notat mutationes status introitus per reportationem internam Ordinis Eventuum cum resolutione 1 ms. T8431C supports high-integrity current inputs in process shutdown, fire and gas, turbine protection and other Trusted safety applications. Selectable line monitoring can identify open- and short-circuit field wiring faults for each channel without applying one setting to the entire module. Front-panel indicators show channel condition, wiring faults, health and Active, Standby or Educated mode. Companion Slot and SmartSlot arrangements allow controlled online replacement when the Trusted system is configured for redundancy. Correct threshold values, field barriers and cable polarization must be confirmed before commissioning. |
|
01 / FIELD CURRENT ACQUISITION
Field current acquisition
Forty sourcing field loops deliver their 4–20 mA signals to the isolated input interface.
|
02 / THREE-SLICE CONVERSION
Three-slice conversion
Each TMR slice measures the channel through its own field-interface circuitry and analog-to-digital conversion path.
|
03 / THRESHOLD AND FAULT EVALUATION
Threshold and fault evaluation
Configured thresholds determine input state while line monitoring distinguishes open and short wiring conditions. Voted channel data, diagnostics and time-stamped state changes are passed to the TMR Processor.
|
|
01 / FORTY SUPERVISED CURRENT CHANNELS
Forty supervised current channels
One module concentrates forty analog input loops while retaining channel-specific line monitoring and status reporting.
|
02 / FAULT-TOLERANT PROCESSING
Processus Fault-Tolerant
Three isolated processing slices allow the safety system to diagnose a fault without losing the complete input function.
|
|
03 / EVENT CHRONOLOGY SUPPORT
Event chronology support
The 1 ms SOE resolution helps correlate process input transitions during trips and post-event analysis.
|
04 / CONTROLLED ONLINE MAINTENANCE
Controlled online maintenance
Companion Slot and SmartSlot strategies support module replacement while the configured redundant path remains available.
|
| 01 | How does ICS Triplex T8431C distinguish a normal current signal from a field wiring fault? | Each channel uses configurable voltage thresholds, and its selectable line-monitoring function identifies open- or short-circuit field wiring conditions. |
| 02 | Which event-timing data can ICS Triplex T8431C provide after a process trip? | The module records channel state changes with 1 ms SOE resolution and a specified timestamp accuracy of +/-10 ms. |
| 03 | Why can ICS Triplex T8431C tolerate a fault in one internal processing slice? | Its three-slice TMR architecture measures and supervises each input independently so the remaining valid paths can sustain the channel result. |
| 04 | Where is ICS Triplex T8431C installed inside a Trusted controller? | It occupies an I/O module slot in a T8100 or T8300 chassis and connects to the selected field termination arrangement. |
| 05 | Quando potest ICS Triplex T8431C substitui in absentia applicationis Trusted? | Substitutio in absentia suadetur, si systema construitur cum Companio-Situs vel SmartSlot configuratione activa-et-standby. |
| 06 | Quid addendum est antequam ICS Triplex T8431C connectitur ad circuitum campi intrinsece securum? | Modulus per se non est intrinsece securus; igitur opus est barriera extrinseca intrinsece secura recte selecta. |