Bureau des ventes directes
Un seul point de contact pour les devis, les livraisons et le soutien aux commandes.
|
VENDITE | Epistula electronica | Telephus WhatsApp |
|---|---|---|---|
| Iimus Pei | [email protected] | +86 18020776782 |
| Modellum | T8451C |
| Output Architecture | Redundantia modularis triplex (TMR) |
| Numerus Exitus | 40 |
| Nominal Output Voltage | 24 V DC |
| Coating Conformativum | Ita |
| Backplane Supply Voltage | 20 to 32 V DC |
| Ratio virtutis | 27 W |
| Tensio Alimentationis Campi | 18 ad 32 V DC |
| Maxima currentis summa ad 50 gradus C | 40 A, limitata ad 8 A per gruppus potentiae |
| Maxima currentis summa ad 60 gradus C | 30 A, limitata ad 6 A per gruppus potentiae |
| Dissipatio potentiae in campo ad 50 °C | 128 W ad currentem maximam gruppi potentiae |
| Dissipatio potentiae in campo ad 60 °C | 96 W ad currentem maximam gruppi potentiae |
| Locus Modi | T8100 or T8300 I/O module slot |
| Isolatio gruppi potentiae | 50 V renfortis, continua inter grupos potentiae |
| Examen typicum isolationis gruppi potentiae | 1411 V DC pro 60 s |
| Isolatio Communis Campi | 50 V renfortis, continua ad commune campi |
| Field common fault insulation | 250 V basic |
| Examen typicum isolationis communis campi | 2436 V DC for 60 s |
| Isolātiō inter canālēs | Nullus |
| Fusio | Non a utente reparabilis |
| Numerus grupporum potentiae | 5 |
| Canalia per gruppus potentiae | 8 |
| Resistentia On-State Exitus | 1.6 ohm |
| Taxatio currentis continuae | 2 A per canalium |
| Currentis Minima in Statu Activato | 50 mA |
| Intervalum Mensurae Currentis | 0 ad 2.7 A, ±5% aut ±5 mA |
| Rangus Mensurationis Voltii | 0 ad 30 V DC, ±2 V DC |
| Maxima tensio tolerata | -1 ad +40 V DC |
| Crosstalk inter canalibus | MENOR QUAM 1% |
| Maxima capacitas oneris | 3000 microfarad |
| Protectio contra curtum circuitum in effluenti | Inclusio electronica |
| Monitorium Lineae | Automaticum per punctum output |
| Resolutio ordinis eventuum | 1 ms |
| Accuratio temporis notati | +/-10 ms |
| Certificatio securitatis | IEC 61508 SIL 3 |
| Temperatura operativa | 0 usque ad +60 gradus C |
| Temperatura servandae | −25 ad +70 gradus C |
| Humiditas operativa et servandi | 10% usque ad 95%, noncondensans |
| Dimensiones | 266 x 31 x 303 mm |
| Pondus | 1.3 KG |
|
Product Profile
Redundantia modularis triplex (TMR)
+ 40 ICS TRIPLEX / TRUSTED SAFETY I/O MODULES
|
T8451C est modulatus digitalis output Trusted TMR cum recubatione conformali, habens quadraginta puncta output 24 V DC disposita in quinque gruppis potentiae isolatis. Omne canale utitur structura commutativa triplicata et monitorata, ita ut onus maneat controlatum post unicum defectum interruptoris aut sectio. Mensurationes automaticae tensionis et currentis output determinare statum canalis et supportare diagnosin circuitus aperti et corti. Protectio electronica latching contra circuitum curtum incorporata est in singulo output, nec fusibilis externus canalis requiritur. Reportatio Ordinis Eventuum notat mutationes output cum resolutione 1 ms. T8451C drives shutdown valves, relays, annunciators and other discrete final elements in high-integrity process applications. Three fail-safe switching paths work together, while group fail-safe switches supervise each eight-channel field-supply group. Front-panel indicators expose output status, wiring faults and module operating mode to maintenance personnel. A Companion Slot or SmartSlot arrangement can support controlled online replacement in a correctly engineered Trusted system. Field current, load capacitance and the shared power-group limit must be reviewed for every connected device. |
|
01 / SAFETY COMMAND RECEPTION
Safety command reception
The Trusted processor delivers the requested output state through the fault-tolerant inter-module bus.
|
02 / TRIPLICATED SWITCH CONTROL
Triplicated switch control
Three independently supervised fail-safe switching paths act on each 24 V DC output channel.
|
03 / LOAD ENERGIZATION
Load energization
The voted switching structure supplies the field device within its channel and power-group limits. Voltage, current and line-state measurements return diagnostic and SOE information to the safety application.
|
|
01 / FIVE ISOLATED POWER GROUPS
Quinque gruppi potestatis isolati
The forty outputs are divided into five groups of eight, supporting structured field-supply distribution and fault containment.
|
02 / PER-CHANNEL CURRENT PROTECTION
Per-channel current protection
Electronic latching limits a shorted output without requiring a user-replaceable fuse on every channel.
|
|
03 / AUTOMATIC WIRING DIAGNOSTICS
Automatic wiring diagnostics
Onboard voltage and current measurements detect open-load, missing-supply and short-circuit conditions.
|
04 / SINGLE-FAULT OUTPUT CONTINUITY
Continuitas output unus-fallus
Dispositio interruptoris TMR sex-elementorum retinet duas vias operativas, cum una lamina commutans integra deficiat.
|
| 01 | Quomodo quadraginta output ICS Triplex T8451C dividuntur pro distributione potentiae in campo? | Organizantur ut quinque gruppi potentiae, octo canales output in singulo gruppo. |
| 02 | Quae limites currentis oneris inspici debent ante connexionem ICS Triplex T8451C? | Non plus quam 2 A continuus per canalum permittatur, et limites currentis totales ac per-gruppus, dependentes a temperatura, observentur. |
| 03 | Cur canalus non-usus ICS Triplex T8451C condicionem sine-onere nuntiare potest? | Monitorium automaticum lineae exspectat currentem supra limitem sine-onere; ideo onus simulatum idoneum forte necessarium est in canalu superviso non-uso. |
| 04 | Quomodo ICS Triplex T8451C controllem output servat post unam viam interruptoris defectam? | Singulus canalus tres vias interruptoris tutae cum monitorio habet, ita ut duae viae superstites onerem portare possint post unius-viae defectum. |
| 05 | Quod responsum protectionis ICS Triplex T8451C ad cortum circuitum in outputu applicat? | Canalis protectionem electronicam latching contra cortum circuitum utitur et faultum resultans pro actione manutentionis refert. |
| 06 | Quae duo intervalla supplicationis ad commissionem ICS Triplex T8451C necessaria sunt? | Suppedita 20 ad 32 V DC in backplane et 18 ad 32 V DC pro supplicatione campi-output. |