Nomen producti: Modulus Ingressus
Nomen marcae: ICS TRIPLEX
Numerus exemplaris: T8310C
Terra Originis: USA
Warranty: 12 menses
Whatsapp:+86 18159889985
Epistula electronica: [email protected]
Nomen marcae: |
ICS TRIPLEX |
Numerus exemplaris: |
T8310C |
Terra Originis: |
USA |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
Tempus expeditionis, si in deposito |
Conditiones solutionis: |
T/T |
|
Praepositus Venalium: |
Stella |
|
Mitte epistulam electronicam: |
|
|
Contactus per Whatsapp: |
The T8310C est Modulus Processus Expander TMR Fidus qui fungitur ut interfacies servus altae disponibilitatis et tolerans defectus inter Expander Bus et Expander Chassis Backplane . Hoc T8310C modulus in sedibus processorum Chassis Expander Fidi residet et permittit systemata chassis multiplex implementari per connexiones cabilium Unshielded Twisted Pair (UTP), dum facultates Inter-Module Bus (IMB) tolerantes defectus et alti latitudinis bandae retinentur . The T8310C habet architecturam Triplicis Modularis Redundantiae cum designo tolerante defectus ex parte hardware et diagnosticis completis pro identificatione celeri defectuum . Cum configurationes hot-standby et module spare supportatae, T8310C permittit strategias reparationis automaticas et manuales .
tolerantia ad defectus 3-2-0 – Architectura TMR certificat operationem continuam per defectum singulum vel multiplex, cum degradatione gratiose ad unicum canalem sanum
Architectura HIFT – Designum tolerans defectus implementatum in hardware praebet responsionem defectuum determinatam cum temporibus agnoscendi et reagendi extremis celeribus
Redundantia slot companion – Duo slot processorum adiacentium in chassidio configurata pro operatione activa/standby cum failover automatico
Extensio longae distantiae – Supportat expansionem usque ad 30 m cupri UTP aut 10 km fibrae opticae, permittens deploymentum chassidiorum I/O remotorum
Substitutio calida – Moduli possunt substitui sine cessatione systematis in configurationibus redundantibus, minuens tempus non operativum
Votatio Byzantina – Mechanismi votationis provecti in utrisque interfacibus Expander Bus et IMB certificantur contra defectus et integritatem datorum
Architectura Triplicis Modularis Redundantis (TMR) – Configuratio in passu coniuncto cum tribus regionibus independentibus containmentis defectuum (FCR A, B, et C)
Designum Fault Tolerant Implementatum in Hardware (HIFT) – Regulae testuum hardware et software dedicatae quae praebent tempora recognitionis et responsionis valde celeria ad defectus
Interfacies Expander Bus – Architectura triplicata punctum-ad-punctum cum mediis separatim commandi et responsionis per canallem; votatio certificat tolerantiam ad defectus cabilorum
Interfacies Inter-Modularis Bus (IMB) – Identica cum IMB Chassis Controlleris, praebens communicationes altius latitudinis cum toleratione defectuum usque ad 12,5 Mbps
Operatio Activa/Standby – Negotiatio automatica inter duo modulos processorum Expander; modus sinistrorsus per definitionem est Activus cum uterque sanus est
Generatio Energiae IMB – Tres fontes energiae independens per diodos ad fasciculum dorsalem IMB; defectus cuiuslibet fontis non afficit reliquos fontes
monitoratio Subsidi 24 V – Monitoratio continua cuiuslibet subsidii 24 V cum informationibus status accessibilibus per processorem TMR
Diagnostica Plena – Numeratores errorum receptionis, monitoratio qualitatis ligaturae, detectio errorum quadram et errorum checksum per singulam ligaturam/FCR
Indicatores LED Anteriores – Diodi luminosi pro statu (per canallem), pro activitate, pro standby et pro activitate communicationis ad celerem aestimationem status
Polarisatio/Clavatura Moduli – Clavatura fabricae-fixa prohibet insertionem in positiones chassis incorrectas
The T8310C operatur ut interfacies serva tolerans defectus, extendens facultates Bus Inter-Modularem (IMB) e uno chasside processorum ad systemata plura chassidum Expander . Modulus construitur circa tres regiones independentes continentionis defectuum (FCR A, B, et C) dispositas in configuratione TMR passu clauso . Quisque FCR continet interfacies ad Bus Expander et IMB, logicam activam/inactivam regulandam, transceptoras communicationum, et fornimenta electrica independentia.
In operatione normali, modulus activus processualis Expander accipit missivas imperativas e chassis processualis TMR per triplicatum bus Expander . Haec missiva re-synchronizantur et votatione maiorum (votatione Byzantina) fiunt antequam ad IMB chassis Expander mittantur . Similiter, responsa ab modulis I/O intra Expander Chassis accepta per IMB veniunt, rursus synchronizantur, votantur, et ad Expander Bus retrahuntur. Responsa ad Expander Processor Module ipsum directa localiter tractantur, cum idoneis responsis generatis. Modulus etiam signa critica controlis, ut Power Failure Warning, System Watchdog, et Command Response Control, triplicata plene transmittit. .
Modulus suas internas tensiones ex duplici redundanti +24 Vdc potestate derivat, quae per connexorem moduli a Trusted Expander Chassis Backplane suppeditatur. Quisque FCR necessarias tensiones separatim generat, tribus independentibus IMB potestatibus per diodos ad backplane provisis. . Defectus vel supervoluptas unius tantum potestatis reliquas potestates non afficit.
Controlis activus/standby localiter per negotiationem inter duos Expander Processor Modules in companion slots installatos administratur. . Interlocks garantunt ut utrumque modulus simul non possit in modum Activum assumere. Cum uterque modulus valet, modulus sinistrorsus per definitionem in operationem Activam transit. Modulus stand-by communicationes inspicit et statum Activum automatio accipere potest ubi defectus detegitur. Substitutio calida permittitur, ita ut moduli vitiosi sine systematis intermissione removeri et substitui possint. . Diagnostica completa continuo qualitatem Expander Bus, errores receptionis, errores frame, errores checksum, et niveles subministrationis 24 V inspicit, omnis status informatio ad TMR Processor pro notificando defectibus et planificando manutenzione accessibilis.
|
Elementum |
Descriptio |
Numerus partis / Referentia |
|
Modulus Expander Processor |
TMR Expander Processor pro Chassis Expander Fideli |
T8310C |
|
Modulus Expander Interface |
TMR Expander Interface pro Chassis Controller |
|
|
Unitas Adapteris Expander Interface |
Adapter inter Expander Interface et fibras/cuprum |
|
|
Fibre Tx/Rx Unit |
Fibre optic transceiver for remote expander connections |
|
|
Expander Interface Hot Link Cable |
Copper UTP cable for Expander Bus connection (30 m max) |
|
|
Fibre Tx/Rx to Expander Processor Cable |
Connects T8314 to remote Expander Processor |
|
|
Expander Interface Adapter to Fibre Tx/Rx Cable |
Connects T8312 to T8314 |
|
|
Cable Hood Assembly |
Interconnects the two Processor slots in the Expander Chassis |
Included with chassis |
|
Trusted Expander Chassis |
19-inch rack chassis for Expander Processor and I/O modules |
T8300 Series |